基于压缩SENSE的回波平面成像扩散加权成像鉴别肝血管瘤与肝转移瘤的诊断能力
这项前瞻性研究纳入30例肝血管瘤和/或肝转移瘤患者,比较并行成像DWI与压缩SENSE DWI对病灶显示及鉴别诊断的能力。肝转移瘤在压缩SENSE DWI上显示更清晰、CNR更高,但两种序列的ADC阈值及鉴别肝血管瘤与肝转移瘤的诊断效能几乎相当。
要点
- 肝转移瘤在压缩SENSE DWI上显示清晰度优于并行成像DWI(两位阅片者均P<.05)
- 肝转移瘤CNR在压缩SENSE DWI更高(P=.008),肝血管瘤CNR无差异(P=.52)
- 两种序列鉴别肝血管瘤与肝转移瘤的ADC阈值、AUC、敏感度和特异度均无显著差异
核心结论
- 肝转移瘤在压缩SENSE DWI上比并行成像DWI更易显示,但两种序列鉴别肝血管瘤与肝转移瘤的ADC阈值和诊断能力几乎相当。
研究设计与样本
- 前瞻性研究纳入30例肝血管瘤和/或肝转移瘤患者,均接受并行成像DWI和压缩SENSE DWI检查。
- 两位放射科医生采用4分法对肝脏病灶显示清晰度进行置信度评分,其中一位额外计算病灶CNR并测量ADC值。
关键影像表现/征象
- 肝转移瘤的显示清晰度在压缩SENSE DWI优于并行成像DWI,两位阅片者比较均P<.05。
诊断标准与关键数值
- 鉴别肝血管瘤与肝转移瘤的ADC阈值:并行成像DWI为1.38×10-3 mm2/s,压缩SENSE DWI为1.37×10-3 mm2/s。
- 两种序列的AUC(P=.86)、敏感度(P>.99)和特异度(P>.99)均无差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the diagnostic abilities of diffusion-weighted imaging (DWI) with parallel imaging (PI-DWI) and that with Compressed SENSE (EPICS-DWI) for differentiating hepatic hemangiomas (HHs) and liver metastases (LMs).
METHOD: This prospective study included 30 participants with HH and/or LM who underwent PI-DWI and EPICS-DWI. Two radiologists assessed the DWI images and assigned confidence scores for hepatic lesions conspicuity using 4-point scale. One of the radiologists additionally calculated the contrast-to-noise ratio (CNR) and measured ADC value of the hepatic lesions. The conspicuity, CNR, and ADC values were compared between the two sequences. A receiver operating characteristic (ROC) analysis was performed to assess the diagnostic abilities of the two sequences for differentiating HHs and LMs.
RESULTS: The conspicuity of LMs was better in EPICS-DWI than in PI-DWI (P < .05 in both radiologists). The CNR of LMs was higher in EPICS-DWI than in PI-DWI (P = .008). No difference was found in the CNR of HHs (P = .52), ADC values for HHs (P = .79), and LMs (P = .29) between the two sequences. To differentiate between HHs and LMs, the cutoff ADC values were 1.38 × 10-3 mm2/s in PI-DWI and 1.37 × 10-3 mm2/s in EPICS-DWI. The area under the ROC curve (P = .86), sensitivity (P > .99), and specificity (P > .99) did not vary.
CONCLUSIONS: The LMs were more visible in EPICS-DWI than in PI-DWI. However, the cutoff ADC values and diagnostic abilities for differentiating HHs and LMs were almost comparable between the two sequences.
引用
- Kaga T, Noda Y, Asano M, et al. Diagnostic ability of diffusion-weighted imaging using echo planar imaging with compressed SENSE (EPICS) for differentiating hepatic hemangioma and liver metastasis. Eur J Radiol. 2023. PMID: 37643558. doi:10.1016/j.ejrad.2023.111059
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。