前瞻性研究连续纳入78例结直肠癌患者,同日行超声、六氟化硫对比增强超声(SHF-CEUS)与全氟丁烷对比增强超声(PFB-CEUS),以对比增强MRI及随访影像为参考标准。结果显示两种微泡检测结直肠癌肝转移的准确率与廓清显影清晰度相当,PFB-CEUS在识别小于10 mm的肝转移灶方面更具优势,而SHF-CEUS对较大、高回声、深部或钙化病灶显示更佳。

要点

  • PFB-CEUS的库普弗期对小于10 mm的结直肠癌肝转移灶廓清显示优于SHF-CEUS的延迟期。
  • SHF-CEUS的延迟期(>120秒)对较大、高回声、深部(>80 mm)或钙化病灶的显示优于PFB-CEUS。
  • 两种微泡检测结直肠癌肝转移的准确率无显著差异(SHF 0.877 vs PFB 0.770,p=0.087)。

核心结论

  • SHF-CEUS与PFB-CEUS检测结直肠癌肝转移的总体准确率和廓清显影清晰度相当。
  • PFB-CEUS在识别小于10 mm的结直肠癌肝转移灶廓清方面具有优势。
  • 较大、高回声、深部或钙化病灶使用SHF-CEUS识别更佳。

研究设计与样本

  • 前瞻性研究,于2021年9月至11月连续纳入78例结直肠癌患者,同日行超声、SHF-CEUS和PFB-CEUS检查。
  • 以对比增强MRI和随访影像为参考标准,由两名盲法阅片者离线评估病灶数量及廓清表现。
  • 共评估230个病灶,其中结直肠癌肝转移219个,良性病灶11个。

关键影像表现/征象

  • 记录每个局灶性肝病灶的大小、深度、回声和钙化情况。
  • 基于延迟期(>120秒)/库普弗期的廓清表现评估结直肠癌肝转移的数量和显影清晰度。

诊断标准与关键数值

  • SHF-CEUS检测结直肠癌肝转移的准确率为0.877,PFB-CEUS为0.770,两者比较p=0.087。
  • 病灶显影清晰度在SHF-CEUS与PFB-CEUS间无显著差异(p=0.344),但PFB-CEUS的清晰度优于SHF-CEUS(p=0.027)。
  • SHF-CEUS延迟期较PFB-CEUS库普弗期识别更多≥10 mm的结直肠癌肝转移灶(p<0.001)。
  • PFB-CEUS库普弗期较SHF-CEUS延迟期识别更多<10 mm的结直肠癌肝转移灶(p<0.001)。
  • 在高回声病灶、深度>80 mm的病灶及钙化病灶中,PFB-CEUS对结直肠癌肝转移的显影清晰度劣于SHF-CEUS(p<0.05)。

临床应用与阅片要点

  • 对于疑似小肠转移灶(<10 mm),可优先选用PFB-CEUS库普弗期评估廓清。
  • 对于较大、高回声、深部(>80 mm)或钙化病灶,SHF-CEUS延迟期(>120秒)显示更优。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare contrast-enhanced ultrasound (CEUS) with microbubbles containing sulfur hexafluoride (SHF) and perfluorobutane (PFB) for the detection of colorectal liver metastasis (CRLM).

METHODS: In this prospective study, conducted from September to November 2021, patients with colorectal cancer were consecutively recruited and underwent same-day ultrasound, SHF-CEUS, and PFB-CEUS. The reference standard was contrast-enhanced MRI and follow-up imaging. The size, depth, echogenicity, and calcification of each focal liver lesion were recorded. The number and conspicuity of CRLMs, based on washout appearance during the late phase (LP) (> 120 s)/Kupffer phase (KP), were evaluated offsite by two blinded readers.

RESULTS: Overall, 230 lesions (CRLMs, n = 219; benign lesions, n = 11) in 78 patients were evaluated. Lesion conspicuity (p = 0.344) and accuracy in the detection of CRLM were comparable for SHF- and PFB-CEUS (0.877 for SHF vs. 0.770 for PFB, p = 0.087). More CRLMs ≥ 10 mm were identified by LP contrast washout in SHF-CEUS than in KP PFB-CEUS (p < 0.001). More CRLMs < 10 mm were identified by KP washout in PFB-CEUS than in LP SHF-CEUS (p < 0.001). Conspicuity was better on PFB-CEUS than on SHF-CEUS (p = 0.027). In hyperechoic lesions, lesions located deeper than 80 mm, and calcified lesions, CRLM conspicuity on PFB-CEUS was inferior to that on SHF-CEUS (p < 0.05).

CONCLUSIONS: The overall accuracy of detection and conspicuity of washout in CRLMs were comparable between SHF and PFB-CEUS. PFB-CEUS has the advantage of identifying washout in small CRLMs. However, larger, hyperechogenic, deep-seated, or calcified lesions were better identified using SHF-CEUS.

CLINICAL RELEVANCE STATEMENT: Accuracy of detection and conspicuity of washout in CRLMs were comparable between SHF- and PFB-CEUS. PFB-CEUS has the advantage in detecting small CRLMs, whereas SHF-CEUS is better for detecting larger, hyperechogenic, deep-seated, or calcified lesions.

KEY POINTS: Contrast-enhanced ultrasound with sulfur hexafluoride in the late phase and perfluorobutane microbubbles in the Kupffer phase were comparable in terms of accuracy in the detection and conspicuity of colorectal liver metastases. Small colorectal liver metastases (< 10 mm) were more often identified in the Kupffer phase contrast-enhanced ultrasound imaging when using perfluorobutane microbubbles. Larger, hyperechogenic, deep-seated, or calcified lesions were better identified in the late phase contrast-enhanced ultrasound imaging (> 120 s) when using sulfur hexafluoride microbubbles.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Qin S, Chen Y, Wang Y, et al. Contrast-enhanced ultrasound with microbubbles containing sulfur hexafluoride and perfluorobutane with Kupffer phase for the detection of colorectal liver metastases. Eur Radiol. 2023. PMID: 37566263. doi:10.1007/s00330-023-10051-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。