深度学习重建CT用于肝转移瘤:低剂量双能CT与标准剂量单能CT的对比
这项前瞻性研究纳入两组各40例受试者,分别接受全剂量单能CT(120-kVp图像,DLIR及IR算法)或降低剂量双能CT(40–60 keV虚拟单能图像,DLIR算法),对应122个和106个转移瘤。降低剂量双能CT联合DLIR在维持病灶检出率的同时实现34%的辐射剂量降低,感知图像质量与全剂量单能CT相当。
要点
- 降低剂量双能CT联合DLIR在肝转移瘤检出上实现34%剂量降低,观察者病灶检出率维持不变。
- 50-keV虚拟单能图像联合DLIR与120-kVp联合DLIR的感知图像质量和病灶显著性相当。
- 40-keV和50-keV虚拟单能图像联合DLIR较120-kVp联合IR改善病灶显著性,感知图像质量相似或更好。
核心结论
- 双能CT辅助DLIR可在检测肝转移瘤时将辐射剂量降低34%,同时保持与全剂量单能CT相当的感知图像质量。
研究设计与样本
- 前瞻性研究,两组各40例受试者,分别接受全剂量单能CT(120-kVp图像,DLIR和IR算法)或降低剂量双能CT(40–60 keV虚拟单能图像,DLIR算法),对应122个和106个转移瘤,两组按年龄、性别比、体重指数和横截面积匹配。
关键影像表现/征象
- 与120-kVp联合IR相比,40-和50-keV虚拟单能图像联合DLIR显示相似的噪声纹理和肝脏-病灶对比噪声比,相似或更高的图像噪声和低对比分辨率,改善的信噪比和病灶显著性,以及相似或更好的感知图像质量。
- 与120-kVp联合DLIR相比,50-keV虚拟单能图像联合DLIR具有相似的低对比分辨率、信噪比、肝脏-病灶对比噪声比、病灶显著性和感知图像质量,但频率噪声纹理更低、图像噪声更高。
- 降低剂量双能CT使辐射剂量降低34%,观察者病灶检出率维持不变。
临床应用与阅片要点
- 降低剂量双能CT联合DLIR在肝转移瘤检测中与全剂量单能CT准确性相当,可节省超过30%的辐射剂量。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess image quality and liver metastasis detection of reduced-dose dual-energy CT (DECT) with deep learning image reconstruction (DLIR) compared to standard-dose single-energy CT (SECT) with DLIR or iterative reconstruction (IR).
METHODS: In this prospective study, two groups of 40 participants each underwent abdominal contrast-enhanced scans with full-dose SECT (120-kVp images, DLIR and IR algorithms) or reduced-dose DECT (40- to 60-keV virtual monochromatic images [VMIs], DLIR algorithm), with 122 and 106 metastases, respectively. Groups were matched by age, sex ratio, body mass index, and cross-sectional area. Noise power spectrum of liver images and task-based transfer function of metastases were calculated to assess the noise texture and low-contrast resolution. The image noise, signal-to-noise ratios (SNR) of liver and portal vein, liver-to-lesion contrast-to-noise ratio (LLR), lesion conspicuity, lesion detection rate, and the subjective image quality metrics were compared between groups on 1.25-mm reconstructed images.
RESULTS: Compared to 120-kVp images with IR, 40- and 50-keV VMIs with DLIR showed similar noise texture and LLR, similar or higher image noise and low-contrast resolution, improved SNR and lesion conspicuity, and similar or better perceptual image quality. When compared to 120-kVp images with DLIR, 50-keV VMIs with DLIR had similar low-contrast resolution, SNR, LLR, lesion conspicuity, and perceptual image quality but lower frequency noise texture and higher image noise. For the detection of hepatic metastases, reduced-dose DECT by 34% maintained observer lesion detection rates.
CONCLUSION: DECT assisted with DLIR enables a 34% dose reduction for detecting hepatic metastases while maintaining comparable perceptual image quality to full-dose SECT.
CLINICAL RELEVANCE STATEMENT: Reduced-dose dual-energy CT with deep learning image reconstruction is as accurate as standard-dose single-energy CT for the detection of liver metastases and saves more than 30% of the radiation dose.
KEY POINTS: • The 40- and 50-keV virtual monochromatic images (VMIs) with deep learning image reconstruction (DLIR) improved lesion conspicuity compared with 120-kVp images with iterative reconstruction while providing similar or better perceptual image quality. • The 50-keV VMIs with DLIR provided comparable perceptual image quality and lesion conspicuity to 120-kVp images with DLIR. • The reduction of radiation by 34% by DLIR in low-keV VMIs is clinically sufficient for detecting low-contrast hepatic metastases.
引用
- Lyu P, Li Z, Chen Y, et al. Deep learning reconstruction CT for liver metastases: low-dose dual-energy vs standard-dose single-energy. Eur Radiol. 2023. PMID: 37532899. doi:10.1007/s00330-023-10033-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。