人工智能工具利用脾脏衰减检测静脉造影剂增强
在32,994例成人、65,449次腹部CT中评估自动AI工具以脾脏衰减判断静脉造影剂(IVCM)状态的能力;初筛61,783次CT的AUC为0.970,脾脏衰减阈值65 HU;最终61,377次CT的AUC为0.999、准确率99.3%;DICOM头信息错误率2.1%高于AI工具的0.7%。
要点
- 脾脏衰减阈值65 HU时,AI工具判断腹部CT有无静脉造影剂的AUC达0.999、准确率99.3%。
- DICOM头信息错误率为2.1%(1278/61,377),AI工具错误率为0.7%(410/61,377)。
- 人工复核2094次不一致检查,61.0%(1278次)为DICOM头错误,19.6%(410次)为AI误分类。
核心结论
- 自动脾脏衰减AI工具在65 HU阈值下检测静脉造影剂高度准确。
研究设计与样本
- 回顾性分析自动AI工具在32,994例成人(平均年龄61.9±14.7岁;男13,869例,女19,125例)的65,449次仰卧位腹部CT(DICOM头显示41,020次有IVCM、24,429次无IVCM)上的表现,检查时间2000年1月1日至2021年12月31日;以DICOM头为初始参考,对不一致检查行人工复核确定真实状态,并行ROC曲线与列联表分析。
诊断标准与关键数值
- 初筛61,783次CT的ROC分析AUC为0.970,Youden指数提示脾脏衰减最佳阈值为65 HU;最终61,377次CT在65 HU阈值下AUC为0.999、准确率99.3%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the ability of an automated AI tool to detect intravenous contrast material (IVCM) in abdominal CT examinations using spleen attenuation.
METHODS: A previously validated automated AI tool measuring the attenuation of the spleen was deployed on a sample of 32,994 adult (age ≥ 18) patients (mean age, 61.9 ± 14.7 years; 13,869 men, 19,125 women) undergoing 65,449 supine position CT examinations (41,020 with and 24,429 without IVCM by DICOM header) from January 1, 2000 to December 31, 2021. After exclusions, receiver operating characteristic (ROC) curve analysis was performed to determine the optimal threshold for binary classification of IVCM status (non-contrast vs IVCM enhanced), which was then applied to the sample. Discordant examinations (i.e., IVCM status determined by AI tool did not match DICOM header) were manually reviewed to establish ground truth. Repeat ROC curve and contingency table analysis were performed to assess AI tool performance.
RESULTS: ROC analysis of the initial study sample of 61,783 CT examinations yielded AUC of 0.970 with Youden index suggesting an optimal spleen attenuation threshold of 65 Hounsfield units (HU). Manual review of 2094 discordant CT examinations revealed discordance due to DICOM header error in 1278 (61.0%) and AI tool misclassification in 410 (19.6%), with 406 (9.4%) meeting exclusion criteria. Analysis of 61,377 CT examinations in the final study sample yielded AUC of 0.999 with accuracy of 99.3% at the 65 HU threshold. Error rate for DICOM header information was 2.1% (1278/61,377) versus 0.7% (410/61,377) for the AI tool.
CONCLUSION: The automated spleen attenuation AI tool was highly accurate for detection of IVCM at a threshold of 65 HU.
引用
- Pooler BD, Fleming CJ, Garrett JW, et al. Artificial intelligence tool detection of intravenous contrast enhancement using spleen attenuation. Abdom Radiol (NY). 2023. PMID: 37634138. doi:10.1007/s00261-023-04020-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。