部分体素插值法减少先天性心脏病患者心脏CT心室容积测量中的部分容积误差
本研究纳入55例先天性心脏病患者(中位年龄12.0岁),评估部分体素插值(PVI)法在心脏CT心室容积测量中减少部分容积误差的效果。结果显示PVI后心室容积指数显著减小(7.4-11.5%),心肌容积指数显著增大(6.2-27.7%),射血分数和心肌质量-容积比显著增大,且心肌质量在收缩末期与舒张末期高度相关(R 0.961-0.990)。PVI法可减少先心病患者心脏CT心室容积测量的部分容积误差,并影响心室肥厚的分类。
要点
- PVI后心室容积指数较前减小7.4-11.5%,心肌容积指数增大6.2-27.7%(P<0.001)。
- PVI后射血分数增大1.6-2.2%,心肌质量-容积比增大19.7-42.5%(P<0.001)。
- PVI使无肥厚比例显著降低(P<0.002),重度肥厚比例显著增加(P<0.032)。
核心结论
- PVI法可减少先天性心脏病患者心脏CT心室容积测量中的部分容积误差。
研究设计与样本
- 研究纳入55例先天性心脏病患者(中位年龄12.0岁),获取心脏CT心室容积测量数据,比较PVI法前后心室和心肌容积、射血分数及心肌质量-容积比。
诊断标准与关键数值
- PVI后心室容积指数较前减小7.4-11.5%(P<0.001)。
- PVI后心肌容积指数较前增大6.2-27.7%(P<0.001)。
- PVI后射血分数增大1.6-2.2%(P<0.001),心肌质量-容积比增大19.7-42.5%(P<0.001)。
- 收缩末期与舒张末期心肌质量指数高度相关(R 0.961-0.990;P<0.001)。
- PVI后无肥厚比例显著降低(P<0.002),重度肥厚比例显著增加(P<0.032)。
临床应用与阅片要点
- 在先天性心脏病患者心脏CT心室容积测量中,PVI法可减少部分容积误差,但会使心室容积指数减小、心肌容积指数增大,并影响心室肥厚分类。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Varying degrees of partial volume error depending on the complexity of the endocardial borders are inevitable in threshold-based cardiac computed tomography (CT) ventricular volumetry. These errors can potentially be reduced by using a partial voxel interpolation (PVI) method, but this has not been tested for cardiac CT ventricular volumetry.
OBJECTIVE: To evaluate the partial volume error-reducing effects of the PVI method in cardiac CT ventricular volumetry among patients with congenital heart disease (CHD).
MATERIALS AND METHODS: The cardiac CT ventricular volumetry data were obtained from 55 patients (median age 12.0 years) with CHD. The ventricular and myocardial volumes, ejection fraction and ventricular mass-volume ratio were quantified and compared before and after the PVI method. The correlation between the myocardial volumes in the end-systolic and end-diastolic phases was tested. The effect of the PVI method on the classification of ventricular hypertrophy was evaluated.
RESULTS: The indexed ventricular volumes after PVI were significantly smaller (7.4-11.5%) than those before PVI (P<0.001). In contrast, the indexed myocardial volumes were significantly larger (6.2-27.7%) after PVI (P<0.001). The ejection fractions and mass-volume ratios were significantly larger (1.6-2.2% and 19.7-42.5%, respectively) after PVI (P<0.001 and P<0.001, respectively). The indexed myocardial masses showed prominently high correlation between the end-systolic and end-diastolic phases (R, 0.961-0.990; P<0.001). The proportions of no and severe hypertrophy were significantly decreased (P<0.002) and increased (P<0.032), respectively, after the application of the PVI method.
CONCLUSION: The PVI method can reduce partial volume error in cardiac CT ventricular volumetry among patients with CHD.
引用
- Goo HW, Park SH. Partial voxel interpolation to reduce partial volume error of cardiac computed tomography ventricular volumetry in patients with congenital heart disease. Pediatr Radiol. 2023. PMID: 37603066. doi:10.1007/s00247-023-05734-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。