文献速递儿科影像心血管CT

部分体素插值法减少先天性心脏病患者心脏CT心室容积测量中的部分容积误差

Partial voxel interpolation to reduce partial volume error of cardiac computed tomography ventricular volumetry in patients with congenital heart disease.
PubMed 文献 · Pediatr Radiol · 2023-08-21

本研究纳入55例先天性心脏病患者(中位年龄12.0岁),评估部分体素插值(PVI)法在心脏CT心室容积测量中减少部分容积误差的效果。结果显示PVI后心室容积指数显著减小(7.4-11.5%),心肌容积指数显著增大(6.2-27.7%),射血分数和心肌质量-容积比显著增大,且心肌质量在收缩末期与舒张末期高度相关(R 0.961-0.990)。PVI法可减少先心病患者心脏CT心室容积测量的部分容积误差,并影响心室肥厚的分类。

要点

  • PVI后心室容积指数较前减小7.4-11.5%,心肌容积指数增大6.2-27.7%(P<0.001)。
  • PVI后射血分数增大1.6-2.2%,心肌质量-容积比增大19.7-42.5%(P<0.001)。
  • PVI使无肥厚比例显著降低(P<0.002),重度肥厚比例显著增加(P<0.032)。

核心结论

  • PVI法可减少先天性心脏病患者心脏CT心室容积测量中的部分容积误差。

研究设计与样本

  • 研究纳入55例先天性心脏病患者(中位年龄12.0岁),获取心脏CT心室容积测量数据,比较PVI法前后心室和心肌容积、射血分数及心肌质量-容积比。

诊断标准与关键数值

  • PVI后心室容积指数较前减小7.4-11.5%(P<0.001)。
  • PVI后心肌容积指数较前增大6.2-27.7%(P<0.001)。
  • PVI后射血分数增大1.6-2.2%(P<0.001),心肌质量-容积比增大19.7-42.5%(P<0.001)。
  • 收缩末期与舒张末期心肌质量指数高度相关(R 0.961-0.990;P<0.001)。
  • PVI后无肥厚比例显著降低(P<0.002),重度肥厚比例显著增加(P<0.032)。

临床应用与阅片要点

  • 在先天性心脏病患者心脏CT心室容积测量中,PVI法可减少部分容积误差,但会使心室容积指数减小、心肌容积指数增大,并影响心室肥厚分类。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Varying degrees of partial volume error depending on the complexity of the endocardial borders are inevitable in threshold-based cardiac computed tomography (CT) ventricular volumetry. These errors can potentially be reduced by using a partial voxel interpolation (PVI) method, but this has not been tested for cardiac CT ventricular volumetry.

OBJECTIVE: To evaluate the partial volume error-reducing effects of the PVI method in cardiac CT ventricular volumetry among patients with congenital heart disease (CHD).

MATERIALS AND METHODS: The cardiac CT ventricular volumetry data were obtained from 55 patients (median age 12.0 years) with CHD. The ventricular and myocardial volumes, ejection fraction and ventricular mass-volume ratio were quantified and compared before and after the PVI method. The correlation between the myocardial volumes in the end-systolic and end-diastolic phases was tested. The effect of the PVI method on the classification of ventricular hypertrophy was evaluated.

RESULTS: The indexed ventricular volumes after PVI were significantly smaller (7.4-11.5%) than those before PVI (P<0.001). In contrast, the indexed myocardial volumes were significantly larger (6.2-27.7%) after PVI (P<0.001). The ejection fractions and mass-volume ratios were significantly larger (1.6-2.2% and 19.7-42.5%, respectively) after PVI (P<0.001 and P<0.001, respectively). The indexed myocardial masses showed prominently high correlation between the end-systolic and end-diastolic phases (R, 0.961-0.990; P<0.001). The proportions of no and severe hypertrophy were significantly decreased (P<0.002) and increased (P<0.032), respectively, after the application of the PVI method.

CONCLUSION: The PVI method can reduce partial volume error in cardiac CT ventricular volumetry among patients with CHD.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Goo HW, Park SH. Partial voxel interpolation to reduce partial volume error of cardiac computed tomography ventricular volumetry in patients with congenital heart disease. Pediatr Radiol. 2023. PMID: 37603066. doi:10.1007/s00247-023-05734-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。