文献速递心血管MR

基于非对比电影心脏磁共振的影像组学预测ST段抬高型心肌梗死患者左心室不良重构

Non-Contrast Cine Cardiac Magnetic Resonance Derived-Radiomics for the Prediction of Left Ventricular Adverse Remodeling in Patients With ST-Segment Elevation Myocardial Infarction.
PubMed 文献 · Korean J Radiol · 2023-01-01

回顾性单中心队列研究纳入244例急性STEMI患者,于PCI后1周和6个月行CMR检查,从1周非对比电影图像提取影像组学特征。LASSO回归构建的RAD评分是LVAR的独立预测因子,训练集AUC为0.82,测试集为0.75;RAD评分加入LVEF后AUC从0.68升至0.82(P=0.018)。

要点

  • 非对比电影CMR影像组学RAD评分可独立预测STEMI后左心室不良重构。
  • RAD评分加入LVEF使AUC从0.68升至0.82(P=0.018)。
  • RAD评分联合梗死面积预测LVAR的AUC为0.84(0.72-0.95)。

核心结论

  • 基于非对比电影CMR的影像组学分析可独立且增量于LVEF预测STEMI后LVAR,并可能为传统CMR参数提供替代方案。

研究设计与样本

  • 回顾性单中心队列研究,纳入244例急性STEMI患者(88.5%男性,57.0±10.3岁),随机分为训练集170例和测试集74例,于PCI后1周和6个月行CMR检查,以6个月时左心室舒张末期容积增加20%定义LVAR,从1周电影图像提取影像组学特征并用LASSO回归分析。

诊断标准与关键数值

  • LVAR定义为急性STEMI后6个月左心室舒张末期容积增加20%。梗死面积OR为1.04(1.00-1.07),P=0.031;RAD评分OR为3.43(2.34-5.28),P<0.001。RAD评分预测LVAR的AUC在训练集为0.82(0.75-0.89),在测试集为0.75(0.62-0.89)。RAD评分联合梗死面积AUC为0.84(0.72-0.95)。RAD评分加入LVEF后AUC从0.68(0.52-0.84)升至0.82(0.70-0.93),P=0.018;与微血管阻塞、梗死面积和LVEF联合预测的AUC 0.79(0.65-0.94)相当(P=0.727)。

临床应用与阅片要点

  • 作者认为,基于非对比电影CMR的影像组学可独立且增量于LVEF预测STEMI后LVAR,并可能为传统CMR参数提供替代方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the predictive value of radiomics features based on cardiac magnetic resonance (CMR) cine images for left ventricular adverse remodeling (LVAR) after acute ST-segment elevation myocardial infarction (STEMI).

MATERIALS AND METHODS: We conducted a retrospective, single-center, cohort study involving 244 patients (random-split into 170 and 74 for training and testing, respectively) having an acute STEMI (88.5% males, 57.0 ± 10.3 years of age) who underwent CMR examination at one week and six months after percutaneous coronary intervention. LVAR was defined as a 20% increase in left ventricular end-diastolic volume 6 months after acute STEMI. Radiomics features were extracted from the one-week CMR cine images using the least absolute shrinkage and selection operator regression (LASSO) analysis. The predictive performance of the selected features was evaluated using receiver operating characteristic curve analysis and the area under the curve (AUC).

RESULTS: Nine radiomics features with non-zero coefficients were included in the LASSO regression of the radiomics score (RAD score). Infarct size (odds ratio [OR]: 1.04 (1.00-1.07); P = 0.031) and RAD score (OR: 3.43 (2.34-5.28); P < 0.001) were independent predictors of LVAR. The RAD score predicted LVAR, with an AUC (95% confidence interval [CI]) of 0.82 (0.75-0.89) in the training set and 0.75 (0.62-0.89) in the testing set. Combining the RAD score with infarct size yielded favorable performance in predicting LVAR, with an AUC of 0.84 (0.72-0.95). Moreover, the addition of the RAD score to the left ventricular ejection fraction (LVEF) significantly increased the AUC from 0.68 (0.52-0.84) to 0.82 (0.70-0.93) (P = 0.018), which was also comparable to the prediction provided by the combined microvascular obstruction, infarct size, and LVEF with an AUC of 0.79 (0.65-0.94) (P = 0.727).

CONCLUSION: Radiomics analysis using non-contrast cine CMR can predict LVAR after STEMI independently and incrementally to LVEF and may provide an alternative to traditional CMR parameters.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. A X, Liu M, Chen T, et al. Non-Contrast Cine Cardiac Magnetic Resonance Derived-Radiomics for the Prediction of Left Ventricular Adverse Remodeling in Patients With ST-Segment Elevation Myocardial Infarction. Korean J Radiol. 2023. PMID: 37634638. doi:10.3348/kjr.2023.0061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。