光子计数探测器与能量积分探测器CT系统冠状动脉图像质量的个体内比较
前瞻性纳入20例临床指征行CCTA的患者,在30天内分别用EID-CT和PCD-CT检查,比较冠状动脉客观与主观图像质量。PCD-CT单能和多能重建的CNR均显著高于EID-CT,肥胖者差异更大;55、60、70 keV主观评分显著更高。PCD-CT可能为包括高BMI患者在内的广泛人群提供更好的冠状动脉显示。
要点
- PCD-CT单能及多能重建的冠状动脉CNR均显著高于EID-CT(均p<0.008)。
- PCD-CT 55、60、70 keV主观评分显著高于EID-CT(均p<0.05)。
- 肥胖者中PCD-CT较EID-CT的CNR提升幅度更大。
核心结论
- PCD-CT较EID-CT改善的客观和主观图像质量可能为广泛患者尤其是高BMI者提供更好的冠状动脉显示。
研究设计与样本
- 前瞻性个体内比较研究,连续纳入20例临床指征行CCTA的患者,在EID-CT系统检查后30天内在PCD-CT系统行研究性CCTA;EID-CT和PCD-CT均重建多能图像,PCD-CT另生成40、45、50、55、60和70 keV虚拟单能图像(VMI)。
关键影像表现/征象
- PCD-CT单能和多能重建的冠状动脉CNR均显著高于EID-CT,肥胖者中差异递增(均p<0.008)。
- 所有VMI重建的主观图像噪声和血管锐利度均显著高于EID-CT(均p<0.008)。
- 55、60和70 keV PCD-CT的所有主观评分均显著高于EID-CT(均p<0.05)。
诊断标准与关键数值
- 两名盲法读者计算每条主要冠状动脉的对比噪声比(CNR)。
- 主观评分包括图像噪声、血管衰减、血管锐利度和整体质量,采用1-5 Likert量表。
- 按BMI分层:高(>30 kg/m2) vs 低(<30 kg/m2)。
临床应用与阅片要点
- PCD-CT的55、60、70 keV VMI在主观噪声、锐利度和整体质量上评分高于EID-CT。
- 高BMI(>30 kg/m2)患者中PCD-CT较EID-CT的CNR提升幅度更大。
局限性
- 样本量20例。
- 30天内的研究性CCTA为前瞻性额外检查。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT).
METHOD: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis.
RESULTS: A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05).
CONCLUSIONS: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.
引用
- Pinos D, Griffith J, Emrich T, et al. Intra-individual comparison of image quality of the coronary arteries between photon-counting detector and energy-integrating detector CT systems. Eur J Radiol. 2023. PMID: 37542817. doi:10.1016/j.ejrad.2023.111008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。