CT冠状动脉造影作为评估心输出量的替代影像方法及其与超声心动图的相关性
研究纳入100例接受前瞻性心电门控冠状动脉CT血管成像的患者,利用测试团注获得的时间-衰减曲线计算心输出量,并与随访二维超声心动图双平面Simpson法测得的心输出量比较。两种方法相关性良好(r=0.77,p<0.001),Bland-Altman分析未见显著差异。作者认为该心输出量估算方法似乎可行,但缺乏进一步临床和参考标准验证时其临床价值尚不确定。
要点
- 利用冠状动脉CT测试团注时间-衰减曲线可估算心输出量,与超声心动图双平面Simpson法相关性良好(r=0.77,p<0.001)。
- CT估算心输出量与超声心动图之间Bland-Altman分析未见显著差异。
- 心输出量与对比剂强化程度的线性回归为CO = -0.16(HUmax) + 7.65。
核心结论
- 利用测试团注估算心输出量的方法似乎可行,但在缺乏进一步临床和参考标准验证的情况下,该参数的临床价值尚不确定。
研究设计与样本
- 研究纳入100例平均年龄55±12岁、接受前瞻性心电门控单源冠状动脉CT血管成像的患者,扫描延迟通过测试团注评估。
关键影像表现/征象
- 利用测试团注获得的时间-衰减曲线计算患者心输出量。
- 心输出量与对比剂强化程度的线性回归为CO = -0.16(HUmax) + 7.65。
诊断标准与关键数值
- CT估算心输出量与二维超声心动图双平面修正Simpson法测得心输出量相关性良好,r=0.77,p<0.001。
- Bland-Altman分析显示两种方法间未见显著差异。
临床应用与阅片要点
- 冠状动脉CT血管成像中测试团注所得时间-衰减曲线可用于估算心输出量。
- 作者认为该心输出量估算方法似乎可行,但临床价值尚不确定,需进一步临床和参考标准验证。
局限性
- 作者指出,在缺乏进一步临床和参考标准验证的情况下,该参数的临床价值尚不确定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess the feasibility and accuracy of cardiac output (CO) obtained using a test bolus in patients scanned with single-source prospective-gated cardiac computed tomography (CT), and comparing it with CO obtained from unenhanced two-dimensional (2D) echocardiography using biplane Simpson's method.
MATERIALS AND METHODS: In the present study, 100 patients with a mean age of 55 ± 12 years who underwent coronary CT angiography with prospective electrocardiogram (ECG)-gated CT in which the scan delay was evaluated using a test bolus. The time-attenuation curves obtained from the test bolus were used to calculate the CO of the patients. The CO obtained was then compared with that obtained after follow-up 2D echocardiography using biplane modified Simpson method.
RESULTS: Linear regression was calculated between the CO and contrast enhancement: CO = -0.16(HUmax) + 7.65. The study showed good correlation between the two methods with r=0.77, p<0.001. On Bland-Altman analysis, no significant difference was noted between the two methods.
CONCLUSION: This less researched method for CO estimation appears feasible; however, the clinical usefulness of this parameter is uncertain in absence of further clinical and reference standard validation.