文献速递儿科影像妇产影像MR

产前MRI测量纵隔移位角作为右侧先天性膈疝风险分层的可行有效工具

Prenatal MRI assessment of mediastinal shift angle as a feasible and effective risk stratification tool in isolated right-sided congenital diaphragmatic hernia.
PubMed 文献 · Eur Radiol · 2023-08-30

本研究纳入27例孤立性右侧先天性膈疝胎儿和53例对照,在胎儿心脏四腔心层面轴位MRI上测量纵隔移位角(MSA),并验证其预测价值。MSA在右侧先天性膈疝组显著高于对照组,对出生后生存、肺动脉高压和ECMO治疗的AUC分别为0.901、0.828和0.813,预测效能与O/E TFLV相似,略优于TFLV、O/E LHR和LHR。作者首次建立右侧先天性膈疝的MSA测量方法,认为其可作为简单有效的风险分层工具。

要点

  • 在胎儿心脏四腔心层面轴位MRI上测量MSA,右侧先天性膈疝组显著高于对照组。
  • MSA预测出生后生存的AUC为0.901(95%CI 0.781-1.000),预测效能良好。
  • MSA对肺动脉高压和ECMO治疗的AUC分别为0.828和0.813,与O/E TFLV相似。

核心结论

  • 作者首次建立适用于右侧先天性膈疝的胎儿MRI纵隔移位角测量方法,并证明MSA可预测出生后生存、肺动脉高压和ECMO治疗。

研究设计与样本

  • 研究纳入27例孤立性右侧先天性膈疝胎儿和53例对照,在胎儿心脏四腔心层面轴位MRI图像上测量纵隔移位角(MSA)。

关键影像表现/征象

  • MSA为矢状中线标志线与触及左心室侧壁的左边界标志线之间的夹角,用于量化右侧先天性膈疝的纵隔移位。
  • MSA在右侧先天性膈疝组显著高于对照组。

诊断标准与关键数值

  • MSA预测出生后生存的AUC为0.901(95%CI 0.781-1.000)。
  • MSA预测肺动脉高压的AUC为0.828(95%CI 0.661-0.994)。
  • MSA预测ECMO治疗的AUC为0.813(95%CI 0.645-0.980)。
  • MSA、LHR、O/E LHR、TFLV和O/E TFLV均与出生后生存、肺动脉高压和ECMO治疗相关(p < 0.05)。
  • MSA预测效能与O/E TFLV相似,略优于TFLV、O/E LHR和LHR。

临床应用与阅片要点

  • 作者认为,新建立的右侧先天性膈疝胎儿MRI纵隔移位角评估方法为患者提供了简单有效的风险分层工具。
  • MSA可预测右侧先天性膈疝除生存外的更多预后信息,且预测效能良好。
  • MSA可作为右侧先天性膈疝简单有效的风险分层工具,以改善出生后管理规划。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a mediastinal shift angle (MSA) measurement method applicable to right-sided congenital diaphragmatic hernia (RCDH) in fetal MRI and to validate the predictive value of MSA in RCDH.

METHODS: Twenty-seven fetuses with isolated RCDH and 53 controls were included in our study. MSA was measured on MRI axial image at the level of four-chamber view of the fetal heart. The angle between the sagittal midline landmark line and the left boundary landmark line touching tangentially the lateral wall of the left ventricle was used to quantify MSA for RCDH. Appropriate statistical analyses were performed to determine whether MSA can be regarded as a valid predictive tool for postnatal outcomes. Furthermore, predictive performance of MSA was compared with that of lung area to head circumference ratio (LHR), observed/expected LHR (O/E LHR), total fetal lung volume (TFLV), and observed/expected TFLV (O/E TFLV).

RESULTS: MSA was significantly higher in the RCDH group than in the control group. MSA, LHR, O/E LHR, TFLV, and O/E TFLV were all correlated with postnatal survival, pulmonary hypertension (PH), and extracorporeal membrane oxygenation (ECMO) therapy (p < 0.05). Value of the AUC demonstrated good predictive performance of MSA for postnatal survival (0.901, 95%CI: (0.781-1.000)), PH (0.828, 95%CI: (0.661-0.994)), and ECMO therapy (0.813, 95%CI: (0.645-0.980)), which was similar to O/E TFLV but slightly better than TFLV, O/E LHR, and LHR.

CONCLUSIONS: We developed a measurement method of MSA for RCDH for the first time and demonstrated that MSA could be used to predict postnatal survival, PH, and ECMO therapy in RCDH.

CLINICAL RELEVANCE STATEMENT: Newly developed MRI assessment method of fetal MSA in RCDH offers a simple and effective risk stratification tool for patients with RCDH.

KEY POINTS: • We developed a measurement method of mediastinal shift angle for right-sided congenital diaphragmatic hernia for the first time and demonstrated its feasibility and reproducibility. • Mediastinal shift angle can predict more prognostic information other than survival in right-sided congenital diaphragmatic hernia with good performance. • Mediastinal shift angle can be used as a simple and effective risk stratification tool in right-sided congenital diaphragmatic hernia to improve planning of postnatal management.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ding W, Gu Y, Wang H, et al. Prenatal MRI assessment of mediastinal shift angle as a feasible and effective risk stratification tool in isolated right-sided congenital diaphragmatic hernia. Eur Radiol. 2023. PMID: 37644150. doi:10.1007/s00330-023-10178-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。