文献速递胸部头颈技术与安全PETCT

基于[18F]FDG最大强度投影图像的深度卷积神经网络鉴别结节病与淋巴瘤

Deep convolutional neural network for differentiating between sarcoidosis and lymphoma based on [18F]FDG maximum-intensity projection images.
PubMed 文献 · Eur Radiol · 2023-08-03

回顾性纳入56例结节病和62例淋巴瘤患者,比较治疗前[18F]FDG PET/CT表现并构建CNN模型。结节病纵隔淋巴结及肺病变FDG摄取更显著,淋巴瘤颈部淋巴结摄取更显著。基于正位和侧位MIP图像的CNN平均准确率0.890、敏感度0.898、特异度0.907、AUC 0.963。

要点

  • 结节病纵隔淋巴结(2、4、7、10站)及肺病变FDG摄取更显著,淋巴瘤颈部淋巴结摄取更显著。
  • 基于正位和侧位MIP PET图像的CNN鉴别结节病与淋巴瘤平均准确率0.890,AUC 0.963。
  • Grad-CAM显示模型关注异常FDG摄取部位,与视觉评估的分布差异一致。

核心结论

  • 基于FDG摄取部位差异的CNN模型在鉴别结节病与恶性淋巴瘤方面表现良好。

研究设计与样本

  • 回顾性收集初诊未经治疗的结节病和恶性淋巴瘤连续患者,均行[18F]FDG PET/CT;2名核医学放射科医师阅片;CNN模型基于MIP PET图像构建,采用k折交叉验证评估;结节病56例,淋巴瘤62例。

关键影像表现/征象

  • 结节病患者纵隔淋巴结和肺病变FDG积聚更显著(均p < 0.001)。
  • 恶性淋巴瘤患者颈部淋巴结FDG积聚更显著(p < 0.001)。
  • 结节病患者纵隔2、4、7、10站淋巴结FDG积聚显著(均p < 0.01)。
  • 恶性淋巴瘤患者纵隔1站淋巴结FDG积聚有倾向性(p = 0.08)。
  • Grad-CAM显示模型关注异常FDG积聚部位。

诊断标准与关键数值

  • 基于正位和侧位MIP图像的CNN模型:平均准确率0.890(95% CI: 0.804-0.977)。
  • 敏感度0.898(95% CI: 0.782-1.000),特异度0.907(95% CI: 0.799-1.000)。
  • AUC 0.963(95% CI: 0.899-1.000)。

临床应用与阅片要点

  • 阅片时可关注FDG积聚部位差异:结节病倾向纵隔淋巴结(2、4、7、10站)和肺病变,淋巴瘤倾向颈部淋巴结。
  • 基于正位和侧位MIP图像的CNN模型可能有助于鉴别全身多器官及淋巴结受累的疾病。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the [18F]FDG PET/CT findings of untreated sarcoidosis and malignant lymphoma (ML) and develop convolutional neural network (CNN) models to differentiate between these diseases using maximum intensity projection (MIP) [18F]FDG PET images.

METHODS: We retrospectively collected data on consecutive patients newly diagnosed with sarcoidosis and ML who underwent [18F]FDG PET/CT before treatment. Two nuclear radiologists reviewed the images. CNN models were created using MIP PET images and evaluated with k-fold cross-validation. The points of interest were visualized using gradient-weighted class activation mapping (Grad-CAM).

RESULTS: A total of 56 patients with sarcoidosis and 62 patients with ML were included. Patients with sarcoidosis had more prominent FDG accumulation in the mediastinal lymph nodes and lung lesions, while those with ML had more prominent accumulation in the cervical lymph nodes (all p < 0.001). For the mediastinal lymph nodes, sarcoidosis patients had significant FDG accumulation in the level 2, 4, 7, and 10 lymph nodes (all p < 0.01). Otherwise, the accumulation in ML patients tended to be in the level 1 lymph nodes (p = 0.08). The CNN model using frontal and lateral MIP images achieved an average accuracy of 0.890 (95% CI: 0.804-0.977), a sensitivity of 0.898 (95% CI: 0.782-1.000), a specificity of 0.907 (95% CI: 0.799-1.000), and an area under the curve of 0.963 (95% CI: 0.899-1.000). Grad-CAM showed that the model focused on the sites of abnormal FDG accumulation.

CONCLUSIONS: CNN models based on differences in FDG accumulation sites archive high performance in differentiating between sarcoidosis and ML.

CLINICAL RELEVANCE STATEMENT: We developed a CNN model using MIP images of [18F]FDG PET/CT to distinguish between sarcoidosis and malignant lymphoma. It achieved high performance and could be useful in diagnosing diseases with involvement across organs and lymph nodes.

KEY POINTS: • There are differences in FDG distribution when comparing whole-body [18F]FDG PET/CT findings in patients with sarcoidosis and malignant lymphoma before treatment. • Convolutional neural networks, a type of deep learning technique, trained with maximum-intensity projection PET images from two angles showed high performance. • A deep learning model that utilizes differences in FDG distribution may be helpful in differentiating between diseases with lesions that are characteristically widespread among organs and lymph nodes.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Aoki H, Miyazaki Y, Anzai T, et al. Deep convolutional neural network for differentiating between sarcoidosis and lymphoma based on [18F]FDG maximum-intensity projection images. Eur Radiol. 2023. PMID: 37535157. doi:10.1007/s00330-023-09937-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。