胎儿与新生儿死亡死后影像学:死后MRI与尸检对非心脏胸腹部异常的诊断价值比较
单中心回顾性研究纳入2015年1月至2021年12月间80例胎儿及围产期死亡病例,比较死后MRI与尸检对7项非心脏胸部及52项腹部异常的诊断一致性。死后MRI与尸检在非心脏胸部及腹部异常的一致性分别为83.1%(95%CI 71.3-83.3)和76.3%(95%CI 65.8-84.2%),Cohen's kappa分别为0.63和0.51。死后MRI对非心脏胸腹部异常总体诊断价值良好,尤其对大的结构异常,可能作为尸检的补充或替代选择。
要点
- 死后MRI与尸检对非心脏胸部异常一致性83.1%(kappa=0.63),对腹部异常一致性76.3%(kappa=0.51)。
- 死后MRI对大的结构异常诊断价值良好,可能作为尸检的补充甚至替代选择。
- 本研究为单中心回顾性研究,共纳入80例胎儿及围产期死亡病例。
核心结论
- 死后MRI对非心脏胸腹部异常总体诊断价值良好,尤其对大的结构异常,可能为家长和医生提供尸检之外的有价值补充,或在家长不同意尸检时作为替代选择。
研究设计与样本
- 单中心回顾性研究,纳入2015年1月至2021年12月间连续80例胎儿及围产期死亡病例,均为先做死后MRI后做尸检者;研究对象为胎龄>18周的胎儿及存活<24小时的早产和足月新生儿;对7项非心脏胸部异常和52项腹部异常进行评分,以尸检与死后MRI所见的一致性为主要结局。
关键影像表现/征象
- 死后MRI与尸检对非心脏胸部异常的一致性为83.1%(95%CI 71.3-83.3),Cohen's kappa=0.63,为实质性一致。
- 死后MRI与尸检对腹部异常的一致性为76.3%(95%CI 65.8-84.2%),Cohen's kappa=0.51,为中等强度一致。
诊断标准与关键数值
- 以尸检作为参考标准,死后MRI对非心脏胸部异常的一致性83.1%(95%CI 71.3-83.3),Cohen's kappa=0.63。
- 以尸检作为参考标准,死后MRI对腹部异常的一致性76.3%(95%CI 65.8-84.2%),Cohen's kappa=0.51。
- 共评估7项非心脏胸部异常和52项腹部异常,逐项评分后判定一致性。
临床应用与阅片要点
- 作者认为死后MRI对非心脏胸腹部异常总体诊断价值良好,尤其对大的结构异常。
- 作者认为死后MRI可能为家长和医生提供尸检之外的有价值补充,或在家长不同意尸检时作为替代选择。
局限性
- 本研究为单中心回顾性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare the diagnostic value and accuracy of post-mortem magnetic resonance imaging (PMMRI) and autopsy for non-cardiac thoracic and abdominal abnormalities in fetal death.
MATERIALS AND METHODS: This single-institution retrospective study included all consecutive cases of fetal and perinatal death between January 2015 and December 2021 for which PMMRI followed by autopsy was conducted. These cases comprised fetuses at >18 weeks of gestation and preterm and term neonates who lived for <24 h. All PMMRI and autopsy reports were re-assessed and scored for seven non-cardiac thoracic and 52 abdominal abnormalities, and concordance between autopsy and PMMRI findings was determined as the primary outcome.
RESULTS: Eighty cases were included in this study. Fetal loss was caused by termination of pregnancy in 80% of cases. Further, the mean gestational age was 166 days (23 weeks and 5 days, range 126-283 days). The concordance between PMMRI and autopsy for non-cardiac thoracic and abdominal abnormalities was 83.1% (95% confidence interval [CI] 71.3-83.3) and 76.3% (95% CI 65.8-84.2%), respectively, with a substantial and moderate strength of agreement (Cohen's kappa = 0.63 and 0.51 respectively).
CONCLUSION: PMMRI exhibited good overall diagnostic value for non-cardiac thoracic and abdominal abnormalities, specifically large structural abnormalities. PMMRI may offer parents and physicians a valuable addition to autopsy for the detection of non-cardiac thoracic and abdominal abnormalities, or even an alternative option when parents do not consent to autopsy.
引用
- Tijssen MPM, Gregoire CAS, Robben SGF, et al. Post-mortem radiology in fetal and neonatal death: the diagnostic value of post-mortem MRI versus autopsy regarding non-cardiac thoracic and abdominal abnormalities. Clin Radiol. 2023. PMID: 37633747. doi:10.1016/j.crad.2023.07.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。