文献速递胸部CT

多维度影像组学分析预测最大径≤3 cm肺腺癌脏层胸膜侵犯

Multi-dimensional radiomics analysis to predict visceral pleural invasion in lung adenocarcinoma of ≤3 cm maximum diameter.
PubMed 文献 · Clin Radiol · 2023-08-03

回顾性纳入391例最大径≤3 cm肺腺癌患者,其中脏层胸膜侵犯阳性142例、阴性249例,基于CT二维和三维感兴趣区提取影像组学特征并构建模型与列线图。二维与三维影像组学模型预测脏层胸膜侵犯的AUC无显著差异,二维列线图判别能力略优且临床效用稍好。

要点

  • 二维与三维影像组学模型预测≤3 cm肺腺癌脏层胸膜侵犯的AUC无显著差异。
  • 二维列线图在训练组和验证组的判别能力均略优于三维列线图。
  • 决策曲线分析和临床影响曲线显示二维列线图临床效用稍好。

核心结论

  • 二维影像组学模型与三维影像组学模型的判别能力相似。
  • 二维列线图对肺腺癌个体脏层胸膜侵犯的预测略优于三维列线图。

研究设计与样本

  • 回顾性纳入391例最大径≤3 cm的肺腺癌患者,其中脏层胸膜侵犯阳性142例、阴性249例。
  • 从CT图像的肿瘤二维和三维感兴趣区提取影像组学特征。
  • 采用逻辑回归机器学习方法结合最优影像组学特征构建二维和三维模型并计算影像组学评分。
  • 整合独立危险因素与影像组学评分构建列线图。
  • 采用受试者工作特征曲线、决策曲线分析、临床影响曲线及AUC评价各模型性能。

诊断标准与关键数值

  • 脏层胸膜侵犯预测:训练组二维模型AUC=0.835、三维模型AUC=0.836,P=0.896;验证组二维模型AUC=0.803、三维模型AUC=0.794,P=0.567。
  • 列线图判别能力:训练组二维AUC=0.867、三维AUC=0.862,P=0.409;验证组二维AUC=0.835、三维AUC=0.827,P=0.558。
  • 二维和三维列线图均优于其对应的影像组学模型和临床模型。

临床应用与阅片要点

  • 决策曲线分析和临床影响曲线显示二维列线图的临床效用稍好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To explore the value of radiomics analysis in preoperatively predicting visceral pleural invasion (VPI) of lung adenocarcinoma (LAC) with ≤3 cm maximum diameter and to compare the performance of two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) radiomics models.

MATERIALS AND METHODS: A total of 391 LAC patients were enrolled retrospectively, of whom 142 were VPI (+) and 249 were VPI (-). Radiomics features were extracted from 2D and 3D regions of interest (ROIs) of tumours in CT images. 2D and 3D radiomics models were developed combining the optimal radiomics features by using the logistic regression machine-learning method and radiomics scores (rad-scores) were calculated. Nomograms were constructed by integrating independent risk factors and rad-scores. The performance of each model was evaluated by using the receiver operator characteristic (ROC) curve, decision curve analysis (DCA), clinical impact curve (CIC), and calculating the area under the curve (AUC).

RESULTS: There was no difference in the VPI prediction between 2D and 3D radiomics models (training group: 2D AUC=0.835, 3D AUC=0.836, p=0.896; validation group: 2D AUC=0.803, 3D AUC=0.794, p=0.567). The 2D and 3D nomograms performed similarly regarding discrimination (training group: 2D AUC=0.867, 3D AUC=0.862, p=0.409, validation group: 2D AUC=0.835, 3D AUC=0.827, p=0.558), and outperformed their corresponding radiomics models and the clinical model. DCA and CIC revealed that the 2D nomogram had slightly better clinical utility.

CONCLUSION: The 2D radiomics model has a similar discrimination capability compared with the 3D radiomics model. The 2D nomogram performs slightly better for individual VPI prediction in LAC.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Huang S, Xu F, Zhu W, et al. Multi-dimensional radiomics analysis to predict visceral pleural invasion in lung adenocarcinoma of ≤3 cm maximum diameter. Clin Radiol. 2023. PMID: 37607844. doi:10.1016/j.crad.2023.07.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。