文献速递骨肌胸部CT

第7胸椎轴位与矢状位CT值在骨质疏松及骨量减少筛查中的价值

The axial and sagittal CT values of the 7th thoracic vertebrae in screening for osteoporosis and osteopenia.
PubMed 文献 · Clin Radiol · 2023-07-27

本研究回顾性纳入1338例同时接受常规胸部CT与双能X线吸收测定(DXA)检查的患者,比较第7胸椎不同平面CT衰减值的差异。矢状位中部测量值低于轴位中部(平均差9 HU,p<0.001,95%CI 7.8-10.1),矢状位中部CT值每降低1单位,骨量减少或骨质疏松风险增加3.6%。以矢状位中部113.7 HU为阈值区分骨质疏松与非骨质疏松,敏感度90%、特异度52.4%;作者认为T7矢状位CT值<113.7 HU者应进一步行DXA检查。

要点

  • T7矢状位中部CT衰减值低于轴位中部,平均差9 HU(95%CI 7.8-10.1,p<0.001)。
  • 矢状位中部CT值每降低1单位,骨量减少或骨质疏松风险增加3.6%。
  • 矢状位中部113.7 HU区分骨质疏松与非骨质疏松:敏感度90%、特异度52.4%。

核心结论

  • T7矢状位中部平面的CT衰减值预测骨质疏松的诊断效能高于轴位平面;矢状位CT值<113.7 HU的患者需进一步行DXA检查。

研究设计与样本

  • 回顾性研究,纳入1338例(平均年龄61.9±11.9岁,54%女性)在1个月内接受常规胸部CT与DXA检查的患者,比较不同平面CT衰减值,采用Logistic回归与ROC分析各平面的诊断差异。

关键影像表现/征象

  • CT衰减值在正常组、骨量减少组、骨质疏松组依次降低。
  • 配对t检验显示轴位中部测量值大于矢状位中部测量值,平均差9 HU,差异有统计学意义(p<0.001,95%CI 7.8-10.1)。

诊断标准与关键数值

  • 以矢状位中部113.7 HU为阈值区分骨质疏松与非骨质疏松(骨量减少+正常),敏感度90%、特异度52.4%。
  • 矢状位中部CT衰减值每降低1单位,骨量减少或骨质疏松风险增加3.6%。

临床应用与阅片要点

  • 作者认为,T7矢状位CT衰减值<113.7 HU的患者需进一步行DXA检查。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the difference in computed tomography (CT) attenuation value of different planes of the 7th thoracic vertebra and investigate the efficacy of axial and sagittal vertebral CT measurements in predicting osteoporosis.

MATERIALS AND METHODS: Patients who underwent routine chest CT and dual-energy X-ray absorptiometry (DXA) within 1 month were included in this retrospective study. The CT attenuation values of different planes were compared. Logistic regression and receiver operating characteristic (ROC) were used to analyse the difference of each plane in the diagnosis of osteoporosis.

RESULTS: The study included 1,338 patients (mean age of 61.9±11.9; 54% female). The CT attenuation values decreased successively in the normal group, osteopenia group, and osteoporosis group. The paired t-test results showed that the mid-axial measurements were greater than mid-sagittal measurements, with a mean difference of 9 HU, the difference was statistically significant (p<0.001, 95% confidence interval [CI] = 7.8-10.1). For each one-unit reduction in mid-sagittal CT attenuation value, the risk of osteopenia or osteoporosis increased by 3.6%. To distinguish osteoporosis from non-osteoporosis (osteopenia + normal), the sensitivity was 90% and the specificity was 52.4% at the mid-sagittal threshold of 113.7 HU.

CONCLUSIONS: The CT attenuation values of mid-sagittal plane have higher diagnostic efficacy than axial planes in predicting osteoporosis. For patients with a sagittal CT attenuation value of <113.7 HU in the T7, further DXA examination is warranted.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang J, Luo X, Zhou R, et al. The axial and sagittal CT values of the 7th thoracic vertebrae in screening for osteoporosis and osteopenia. Clin Radiol. 2023. PMID: 37573241. doi:10.1016/j.crad.2023.07.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。