儿童患者超短回波时间MRI气道管腔的半自动分割与分析
研究开发了儿童气管至三级支气管的超短回波时间(UTE)MRI气道半自动分割流程,29例7-18岁参与者(健康7例、囊性纤维化11例、哮喘6例、早产儿5例)在3T下行三维堆叠螺旋UTE扫描;观察者内与观察者间分割DSC分别为0.88和0.80,ICC分别为0.95和0.89;管腔直径与FEV1及FVC显著相关(P<.05)。
要点
- UTE MRI气道分割从气管至三级支气管在儿童中可行,观察者内DSC 0.88、观察者间DSC 0.80。
- 分割变异性从气管向三级支气管增大,观察者内DSC由0.91降至0.64,观察者间由0.84降至0.51。
- UTE MRI管腔直径与FEV1及FVC显著相关(P<.05)。
核心结论
- 儿童气管至三级支气管的UTE MRI气道分割可行,管腔测量可重复且与肺功能相关。
研究设计与样本
- 共29例7-18岁参与者(健康7例、囊性纤维化11例、哮喘6例、早产儿5例),在3T下行三维堆叠螺旋UTE扫描;两名独立观察者使用本院开发的流程分割,观察者1在1个月后重复分割;采用区域生长伴泄漏检测提取,必要时手动编辑,气道树经骨架化、修剪和标记,管腔直径用射线投射法测量。
关键影像表现/征象
- 气道分割与管腔直径的观察者内DSC为0.88,观察者间DSC为0.80。
- 观察者内ICC为0.95,观察者间ICC为0.89。
- 变异性从气管至三级支气管增大:观察者内DSC 0.91-0.64、ICC 0.91-0.49;观察者间DSC 0.84-0.51、ICC 0.89-0.21。
诊断标准与关键数值
- 观察者内重复性:分割与管腔直径DSC 0.88,ICC 0.95。
- 观察者间重复性:分割与管腔直径DSC 0.80,ICC 0.89。
- 观察者内从气管至三级支气管:DSC 0.91-0.64,ICC 0.91-0.49。
- 观察者间从气管至三级支气管:DSC 0.84-0.51,ICC 0.89-0.21。
临床应用与阅片要点
- UTE MRI可用于儿童气道从气管至三级支气管的分割与管腔直径测量,观察者内重复性优于观察者间。
- 越向三级支气管,分割与管腔测量的变异性越大,阅片与报告时需注意远端气道测量的可重复性下降。
- UTE MRI管腔直径与FEV1及FVC显著相关(P<.05),可作为肺功能相关的影像指标。
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Ultra short echo time (UTE) magnetic resonance imaging (MRI) pulse sequences have shown promise for airway assessment, but the feasibility and repeatability in the pediatric lung are unknown. The purpose of this work was to develop a semiautomated UTE MRI airway segmentation pipeline from the trachea-to-tertiary airways in pediatric participants and assess repeatability and lumen diameter correlations to lung function.
MATERIALS AND METHODS: A total of 29 participants (n = 7 healthy, n = 11 cystic fibrosis, n = 6 asthma, and n = 5 ex-preterm), aged 7-18 years, were imaged using a 3D stack-of-spirals UTE examination at 3 T. Two independent observers performed airway segmentations using a pipeline developed in-house; observer 1 repeated segmentations 1 month later. Segmentations were extracted using region-growing with leak detection, then manually edited if required. The airway trees were skeletonized, pruned, and labeled. Airway lumen diameter measurements were extracted using ray casting. Intra- and interobserver variability was assessed using the Sørensen-Dice coefficient (DSC) and intra-class correlation coefficient (ICC). Correlations between lumen diameter and pulmonary function were assessed using Spearman's correlation coefficient.
RESULTS: For airway segmentations and lumen diameter, intra- and interobserver DSCs were 0.88 and 0.80, while ICCs were 0.95 and 0.89, respectively. The variability increased from the trachea-to-tertiary airways for intra- (DSC: 0.91-0.64; ICC: 0.91-0.49) and interobserver (DSC: 0.84-0.51; ICC: 0.89-0.21) measurements. Lumen diameter was significantly correlated with forced expiratory volume in 1 second and forced vital capacity (P < .05).
CONCLUSION: UTE MRI airway segmentation from the trachea-to-tertiary airways in pediatric participants across a range of diseases is feasible. The UTE MRI-derived lumen measurements were repeatable and correlated with lung function.
引用
- Genkin D, Zanette B, Grzela P, et al. Semiautomated Segmentation and Analysis of Airway Lumen in Pediatric Patients Using Ultra Short Echo Time MRI. Acad Radiol. 2023. PMID: 37550154. doi:10.1016/j.acra.2023.07.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。