文献速递胸部外周血管CT

人工智能算法在减少常规门静脉期胸部CT中漏诊偶发性急性肺栓塞方面的附加价值

Added value of an artificial intelligence algorithm in reducing the number of missed incidental acute pulmonary embolism in routine portal venous phase chest CT.
PubMed 文献 · Eur Radiol · 2023-08-03

本研究回顾性分析2020年5月27日至12月31日连续3089例常规对比增强胸部CT,由CE认证和FDA批准的人工智能算法检测偶发性急性肺栓塞,并与初始报告比较。参考标准中偶发性急性肺栓塞患病率为2.2%(67/3089),人工智能敏感度95.5%显著高于初始报告62.7%(p<0.001),特异度两者均很高(99.6% vs 99.9%,p=0.012),人工智能额外检出25例初始未报告肺栓塞,占全部阳性病例的37.3%。

要点

  • 人工智能算法敏感度95.5%显著高于初始报告62.7%(p<0.001),额外检出25例初始未报告肺栓塞。
  • 人工智能假阳性仅轻度增加(11例 vs 2例),所致阳性预测值85.3%显著低于初始报告95.5%(p=0.047)。
  • 偶发性急性肺栓塞在常规门静脉期胸部CT中患病率为2.2%(67/3089),人工智能可减少漏诊。

核心结论

  • 人工智能算法在诊断偶发性肺栓塞方面表现出高诊断准确度,额外检出25例初始未报告肺栓塞,占全部阳性病例的37.3%。

研究设计与样本

  • 回顾性分析2020年5月27日至12月31日连续3089例因常规对比增强胸部CT转诊至放射科的患者,由CE认证和FDA批准的人工智能算法分析,并与初始报告比较诊断性能;不一致发现由两名阅片者独立评估确定参考标准,意见不一致时由另一名经验丰富的心胸放射科医师结合初始报告和人工智能输出裁定。

关键影像表现/征象

  • 偶发性急性肺栓塞在参考标准中的患病率为2.2%(67/3089例)。
  • 人工智能检出25例初始未报告的肺栓塞,其中3例为中心型/肺叶型肺栓塞。
  • 人工智能假阳性发现为11例,初始报告为2例。

诊断标准与关键数值

  • 人工智能算法检测偶发性急性肺栓塞的敏感度为95.5%,初始报告为62.7%(p<0.001)。
  • 人工智能算法特异度为99.6%,初始报告为99.9%(p=0.012)。
  • 人工智能算法阳性预测值为85.3%,初始报告为95.5%(p=0.047)。

临床应用与阅片要点

  • 在常规门静脉期胸部CT日常实践中,人工智能算法支持可防止漏诊偶发性急性肺栓塞,且不会带来高负担的假阳性病例。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to evaluate the incremental value of artificial intelligence (AI) compared to the diagnostic accuracy of radiologists alone in detecting incidental acute pulmonary embolism (PE) on routine portal venous contrast-enhanced chest computed tomography (CT).

METHODS: CTs of 3089 consecutive patients referred to the radiology department for a routine contrast-enhanced chest CT between 27-5-2020 and 31-12-2020, were retrospectively analysed by a CE-certified and FDA-approved AI algorithm. The diagnostic performance of the AI was compared to the initial report. To determine the reference standard, discordant findings were independently evaluated by two readers. In case of disagreement, another experienced cardiothoracic radiologist with knowledge of the initial report and the AI output adjudicated.

RESULTS: The prevalence of acute incidental PE in the reference standard was 2.2% (67 of 3089 patients). In 25 cases, AI detected initially unreported PE. This included three cases concerning central/lobar PE. Sensitivity of the AI algorithm was significantly higher than the outcome of the initial report (respectively 95.5% vs. 62.7%, p < 0.001), whereas specificity was very high for both (respectively 99.6% vs 99.9%, p = 0.012). The AI algorithm only showed a slightly higher amount of false-positive findings (11 vs. 2), resulting in a significantly lower PPV (85.3% vs. 95.5%, p = 0.047).

CONCLUSION: The AI algorithm showed high diagnostic accuracy in diagnosing incidental PE, detecting an additional 25 cases of initially unreported PE, accounting for 37.3% of all positive cases.

CLINICAL RELEVANCE STATEMENT: Radiologist support from AI algorithms in daily practice can prevent missed incidental acute PE on routine chest CT, without a high burden of false-positive cases.

KEY POINTS: • Incidental pulmonary embolism is often missed by radiologists in non-diagnostic scans with suboptimal contrast opacification within the pulmonary trunk. • An artificial intelligence algorithm showed higher sensitivity detecting incidental pulmonary embolism on routine portal venous chest CT compared to the initial report. • Implementation of artificial intelligence support in routine daily practice will reduce the number of missed incidental pulmonary embolism.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Langius-Wiffen E, de Jong PA, Mohamed Hoesein FA, et al. Added value of an artificial intelligence algorithm in reducing the number of missed incidental acute pulmonary embolism in routine portal venous phase chest CT. Eur Radiol. 2023. PMID: 37532902. doi:10.1007/s00330-023-10029-z