基于深度学习的自动临床靶区勾画的多部位肿瘤单中心临床评估
本研究纳入577例鼻咽癌、食管癌、保乳术后、乳腺癌根治术后、宫颈癌、前列腺癌和直肠癌患者,比较四种深度学习模型(Flexnet、Unet、Vnet、Segresnet)在CT图像上自动勾画临床靶区(CTV)的表现,以放疗科医生手动勾画为参考标准。独立测试集显示多数患者DSC>0.8,但食管癌DSC仅0.62-0.64;主观评审中82.65%的预测CTV被评为临床可接受(8.68%)或需微小修改(73.97%),无患者被评为拒绝。结论认为自动勾画可作为初始模板帮助肿瘤科医生节省CTV勾画时间。
要点
- 独立测试集中多数部位肿瘤自动勾画CTV的DSC>0.8,但食管癌DSC为0.62-0.64,明显低于其他部位。
- 主观评审中82.65%的预测CTV被评为临床可接受(8.68%)或需微小修改(73.97%),无患者被评为拒绝。
- 自动勾画轮廓可作为初始模板,帮助肿瘤科医生节省CTV勾画时间。
核心结论
- 基于深度学习的自动勾画在多种肿瘤的CTV勾画中达到可接受的精度,可作为初始模板帮助肿瘤科医生节省勾画时间,并显示出提高放疗临床效率的潜力。
研究设计与样本
- 单中心研究,纳入577例患者,包括鼻咽癌(n=34)、食管癌(n=40)、保乳术后(左侧n=71,右侧n=71)、乳腺癌根治术后(左侧n=43,右侧n=37)、宫颈癌(根治性放疗n=45,术后n=85)、前列腺癌(n=42)和直肠癌(n=109)。以放疗科医生手动勾画的CTV为参考标准,评估Flexnet、Unet、Vnet和Segresnet四种模型(均为医疗产品「AccuLearning AI模型训练平台」中的商用模型)。数据按5:1:4比例分为训练集、验证集和测试集。
诊断标准与关键数值
- 客观评价采用Dice相似系数(DSC)和Hausdorff距离(HD);独立测试集中多数患者DSC>0.8,食管癌患者DSC为0.62-0.64。主观评价由肿瘤科医生对测试集分割轮廓进行视觉评分,82.65%的预测CTV评分为临床可接受(8.68%)或需微小修改(73.97%),无患者被评为拒绝。
临床应用与阅片要点
- 作者认为自动生成的轮廓可作为初始模板,帮助肿瘤科医生节省CTV勾画时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The large variability in tumor appearance and shape makes manual delineation of the clinical target volume (CTV) time-consuming, and the results depend on the oncologists' experience. Whereas deep learning techniques have allowed oncologists to automate the CTV delineation, multi-site tumor analysis is often lacking in the literature. This study aimed to evaluate the deep learning models that automatically contour CTVs of tumors at various sites on computed tomography (CT) images from objective and subjective perspectives.
METHODS AND MATERIALS: 577 patients were selected for the present study, including nasopharyngeal (n = 34), esophageal (n = 40), breast-conserving surgery (BCS) (left-sided, n = 71; right-sided, n = 71), breast-radical mastectomy (BRM) (left-sided, n = 43; right-sided, n = 37), cervical (radical radiotherapy, n = 45; postoperative, n = 85), prostate (n = 42), and rectal (n = 109) carcinomas. Manually delineated CTV contours by radiation oncologists are served as ground truth. Four models were evaluated: Flexnet, Unet, Vnet, and Segresnet, which are commercially available in the medical product "AccuLearning AI model training platform". The data were divided into the training, validation, and testing set at a ratio of 5:1:4. The geometric metrics, including Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD), were calculated for objective evaluation. For subjective assessment, oncologists rated the segmentation contours of the testing set visually.
RESULTS: High correlations were observed between automatic and manual contours. Based on the results of the independent test group, most of the patients achieved satisfactory quantitative results (DSC > 0.8), except for patients with esophageal carcinoma (DSC: 0.62-0.64). The subjective review indicated that 82.65% of predicted CTVs scored either as clinically accepting (8.68%) or requiring minor revision (73.97%), and no patients were scored as rejected.
CONCLUSION: This experimental work demonstrated that auto-generated contours could serve as an initial template to help oncologists save time in CTV delineation. The deep learning-based auto-segmentations achieve acceptable accuracy and show the potential to improve clinical efficiency for radiotherapy of a variety of cancer.
引用
- Hou Z, Gao S, Liu J, et al. Clinical evaluation of deep learning-based automatic clinical target volume segmentation: a single-institution multi-site tumor experience. Radiol Med. 2023. PMID: 37597126. doi:10.1007/s11547-023-01690-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。