比较1.5 T与3 T磁共振血管成像使用深度学习计算机辅助检测软件检测脑动脉瘤
本研究为单中心回顾性研究,评估90例患者头MRA(1.5 T与3 T各45例)使用深度学习辅助检测软件EIRL_an检测脑动脉瘤的诊断性能。结果显示1.5 T与3 T的敏感度均高(0.875‒1),但3 T的每例假阳性数显著高于1.5 T(1.511 vs. 2.578,p < 0.001),假阳性最常见原因为血管起始/分叉处、血流相关伪影和动脉粥样硬化,两种场强相似。
要点
- 1.5 T与3 T MRA使用EIRL_an检测脑动脉瘤的敏感度均高(0.875‒1)。
- 3 T MRA的每例假阳性数显著高于1.5 T(1.511 vs. 2.578,p < 0.001)。
- 假阳性最常见原因为血管起始/分叉处、血流相关伪影和动脉粥样硬化,两种场强相似。
核心结论
- EIRL_an在3 T MRA上检测到的假阳性病灶显著多于1.5 T MRA;作者认为该数据可能帮助MRA经验有限的医师正确诊断动脉瘤。
研究设计与样本
- 单中心回顾性研究,纳入90例临床头MRA患者(1.5 T与3 T各45例),共51例患者有70个动脉瘤;使用非算法训练数据集厂商的MRI设备;由两名放射科医师确定参考标准、EIRL_an候选病灶的准确性及假阳性原因。
诊断标准与关键数值
- EIRL_an检测脑动脉瘤的敏感度在1.5 T和3 T MRA均为0.875‒1;每例假阳性数3 T MRA为2.578,1.5 T MRA为1.511,差异有统计学意义(p < 0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the diagnostic performance of 1.5 T versus 3 T magnetic resonance angiography (MRA) for detecting cerebral aneurysms with clinically available deep learning-based computer-assisted detection software (EIRL aneurysm® [EIRL_an]), which has been approved by the Japanese Pharmaceuticals and Medical Devices Agency. We also sought to analyze the causes of potential false positives.
METHODS: In this single-center, retrospective study, we evaluated the MRA scans of 90 patients who underwent head MRA (1.5 T and 3 T in 45 patients each) in clinical practice. Overall, 51 patients had 70 aneurysms. We used MRI from a vendor not included in the dataset used to create the EIRL_an algorithm. Two radiologists determined the ground truth, the accuracy of the candidates noted by EIRL_an, and the causes of false positives. The sensitivity, number of false positives per case (FPs/case), and the causes of false positives were compared between 1.5 T and 3 T MRA. Pearson's χ2 test, Fisher's exact test, and the Mann‒Whitney U test were used for the statistical analyses as appropriate.
RESULTS: The sensitivity was high for 1.5 T and 3 T MRA (0.875‒1), but the number of FPs/case was significantly higher with 3 T MRA (1.511 vs. 2.578, p < 0.001). The most common causes of false positives (descending order) were the origin/bifurcation of vessels/branches, flow-related artifacts, and atherosclerosis and were similar between 1.5 T and 3 T MRA.
CONCLUSION: EIRL_an detected significantly more false-positive lesions with 3 T than with 1.5 T MRA in this external validation study. Our data may help physicians with limited experience with MRA to correctly diagnose aneurysms using EIRL_an.
引用
- Tajima T, Akai H, Yasaka K, et al. Comparison of 1.5 T and 3 T magnetic resonance angiography for detecting cerebral aneurysms using deep learning-based computer-assisted detection software. Neuroradiology. 2023. PMID: 37646791. doi:10.1007/s00234-023-03216-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。