文献速递神经MR

前瞻性比较T1-SPACE与MPRAGE识别颅内黑色素瘤转移患者内在T1高信号的研究

Prospective Comparison of T1-SPACE and MPRAGE for the Identification of Intrinsic T1 Hyperintensity in Patients with Intracranial Melanoma Metastases.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-08-24

本研究前瞻性比较了增强前3D-TSE(T1-SPACE)与3D-GRE(MPRAGE)序列在颅内黑色素瘤转移患者中识别内在T1高信号的能力。20例检查共214个病灶显示内在T1高信号,两位神经放射科医生独立阅片发现,大多数病灶(两位读者平均81.8%)在T1-SPACE上内在T1高信号不如MPRAGE明显,仅1.4%的病灶在T1-SPACE上更明显。结论认为,增强前内在T1高信号在MPRAGE上比T1-SPACE更明显,在同时进行增强后3D-TSE和3D-GRE扫描或不使用静脉对比剂时,应优先选择3D-GRE作为增强前T1WI序列。

要点

  • 增强前内在T1高信号在MPRAGE上比T1-SPACE更明显,两位读者平均81.8%的病灶如此。
  • 仅1.4%的病灶内在T1高信号在T1-SPACE上更明显。
  • 黑色素和血产物导致的内在T1高信号在T1-SPACE上均不如MPRAGE明显。

核心结论

  • 增强前内在T1高信号在MPRAGE上比T1-SPACE更明显;在颅内黑色素瘤转移患者中,当增强后同时进行3D-TSE和3D-GRE扫描或不使用静脉对比剂时,应优先选择3D-GRE作为增强前T1WI序列。

研究设计与样本

  • 前瞻性研究,纳入既往报告有内在T1高信号的转移性黑色素瘤患者,在3T设备上进行MRI检查,包括增强前3D-GRE(MPRAGE)和3D-TSE T1-SPACE序列,由2名神经放射科医生独立阅片,共20例检查、214个显示内在T1高信号的病灶。

关键影像表现/征象

  • 两位读者均发现,大多数评估的病灶(两位读者平均81.8%)在T1-SPACE上内在T1高信号不如MPRAGE明显。
  • 内在T1高信号归因于黑色素和血产物的病灶,在T1-SPACE上均不如MPRAGE明显。
  • 内在T1高信号在T1-SPACE上更明显的病灶仅占1.4%。

诊断标准与关键数值

  • 采用5分制比较两种序列上每个病灶的明显程度。
  • 评估内在T1高信号归因于黑色素、血产物或两者。

临床应用与阅片要点

  • 在颅内黑色素瘤转移患者中,当增强后同时进行3D-TSE和3D-GRE扫描或不使用静脉对比剂时,应优先选择3D-GRE作为增强前T1WI序列以识别内在T1高信号。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Volumetric TSE (3D-TSE) techniques are increasingly replacing volumetric magnetization-prepared gradient recalled-echo (3D-GRE) sequences due to improved metastasis detection. In addition to providing a baseline for assessing postcontrast enhancement, precontrast T1WI also identifies intrinsic T1 hyperintensity, for example, reflecting melanin or blood products. The ability of precontrast 3D-TSE to demonstrate intrinsic T1 hyperintensity is not clear from the literature; thus, this study compares precontrast 3D-TSE and 3D-GRE sequences for identifying intrinsic T1 hyperintensity in patients with metastatic melanoma.

MATERIALS AND METHODS: Patients with metastatic melanoma and previously reported intrinsic T1 hyperintensity were identified. MRIs were performed at 3T including both 3D-GRE (MPRAGE) and 3D-TSE T1 sampling perfection with application-optimized contrasts by using different flip angle evolution (T1-SPACE) sequences precontrast. Axial 1-mm slices of both T1WI sequences were independently reviewed by 2 neuroradiologists, comparing the conspicuity of each lesion between the 2 sequences according to a 5-point scale and assessing whether the intrinsic T1 hyperintensity was attributable to melanin, blood products, or both.

RESULTS: Twenty examinations were performed, with a total of 214 lesions demonstrating intrinsic T1 hyperintensity. Both readers found that intrinsic T1 hyperintensity was less conspicuous with T1-SPACE compared with MPRAGE for most lesions assessed (81.8%, averaged across both readers), including for lesions with intrinsic T1 hyperintensity attributable to melanin and blood products. Intrinsic T1 hyperintensity was rarely more conspicuous on T1-SPACE (1.4%).

CONCLUSIONS: Precontrast intrinsic T1 hyperintensity is more conspicuous with MPRAGE than T1-SPACE. In patients with metastatic melanoma, 3D-GRE should be preferred as the precontrast T1WI sequence when both 3D-TSE and 3D-GRE are performed postcontrast and when not administering IV contrast.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Lasocki A, Stuckey SL, Caspersz L, et al. Prospective Comparison of T1-SPACE and MPRAGE for the Identification of Intrinsic T1 Hyperintensity in Patients with Intracranial Melanoma Metastases. AJNR Am J Neuroradiol. 2023. PMID: 37620155. doi:10.3174/ajnr.A7975

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。