压缩SENSE对图像质量和缩短MRI采集时间的评估:一项临床验证研究
本研究对95例不同解剖区域的MRI扫描分别采用标准序列和压缩SENSE(CS)加速序列,由6名盲法亚专科放射科医师进行配对评估。CS使总扫描时间减少32%,图像质量在关节和体部扫描中与标准序列等效,在脑和脊柱扫描中略低但仍可诊断,总体临床接受度为88%。
要点
- CS使总扫描时间减少32%,脊柱平均节省68秒(减少44%),脑平均节省86秒(减少37%)。
- 颅内3D-TOF MRA时间节省最多(202秒,减少56%)。
- CS在关节和体部扫描的整体图像质量与标准序列等效(P>.05),脑和脊柱略低但仍可诊断。
核心结论
- CS显著缩短MR采集时间,同时维持可接受的图像质量;CS的应用可能改善科室工作流程并提升患者诊疗。
研究设计与样本
- 临床验证研究,纳入95例不同解剖区域的MRI扫描,每例均采集标准协议序列(SS)和CS加速序列,由6名盲法亚专科放射科医师对匿名配对序列进行随机展示和评分。
诊断标准与关键数值
- 采用五点Likert量表评估感知锐利度、感知信噪比、病灶可见度和伪影(1:SS优;3:等效;5:CS优),采用四点Likert量表评估整体图像质量(1:最低质量;4:最高质量)。
临床应用与阅片要点
- CS使总扫描时间减少32%,脊柱平均节省68秒(减少44%),脑平均节省86秒(减少37%),颅内3D-TOF MRA节省202秒(减少56%);CS在感知锐利度、感知信噪比和病灶可见度上略逊于SS(平均评分2.32-2.96,P<.001);关节和体部扫描整体图像质量CS与SS等效(CS=3.02-3.37,SS=3.04-3.68,P>.05);脑和脊柱扫描整体图像质量CS略低(CS平均2.79-3.05,SS平均3.13-3.43,P=.021)但仍可诊断;CS总体临床接受度88%,体部扫描完全接受(100%),其他区域接受度68%-95%。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To evaluate the effect of compressed SENSE (CS) in clinical settings on scan time reduction and image quality.
MATERIALS AND METHODS: Ninety-five magnetic resonance imaging (MRI) scans from different anatomical regions were acquired, consisting of a standard protocol sequence (SS) and sequence accelerated with CS. Anonymized paired sequences were randomly displayed and rated by six blinded subspecialty radiologists. Side-by-side evaluation on perceived sharpness, perceived signal-to-noise-ratio (SNR), lesion conspicuity, and artifacts were compared and scored on a five-point Likert scale, and individual image quality was evaluated on a four-point Likert scale.
RESULTS: CS reduced overall scan time by 32% while maintaining acceptable MRI quality for all regions. The largest time savings were seen in the spine (mean = 68 seconds, 44% reduction) followed by the brain (mean = 86 seconds, 37% reduction). The sequence with maximum time savings was intracranial 3D-time-of-flight magnetic resonance angiography (202 seconds, 56% reduction). CS was mildly inferior to SS on perceived sharpness, perceived SNR, and lesion conspicuity (mean scores = 2.32-2.96, P < .001 [1: SS superior; 3: equivalent; 5: CS superior]). CS was equivalent to SS for joint and body scans on overall image quality (CS = 3.02-3.37, SS = 3.04-3.68, P > .05, [1: lowest quality and 4: highest quality]). The overall image quality of CS was slightly less for brain and spine scans (mean CS = 2.79-3.05, mean SS = 3.13-3.43, P = .021) but still diagnostic. Good overall clinical acceptance for CS (88%) was noted with full clinical acceptance for body scans (100%) and high acceptance for other regions (68%-95%).
CONCLUSION: CS significantly reduced MR acquisition time while maintaining acceptable image quality. The implementation of CS may improve departmental workflows and enhance patient care.
引用
- Seow P, Kheok SW, Png MA, et al. Evaluation of Compressed SENSE on Image Quality and Reduction of MRI Acquisition Time: A Clinical Validation Study. Acad Radiol. 2023. PMID: 37648581. doi:10.1016/j.acra.2023.07.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。