文献速递神经MR

基于标准MRI和图像到图像转换技术定量合成脑肿瘤脑血容量图

Quantitative Cerebral Blood Volume Image Synthesis from Standard MRI Using Image-to-Image Translation for Brain Tumors.
PubMed 文献 · Radiology · 2023-01-01

本研究基于756例回顾性MRI检查,训练两种图像到图像转换算法从标准MRI序列合成脑血容量图,以bookend技术DSC MRI生成的定量CBV图为参考标准。采用三维编码器-解码器网络(输入T1WI、增强T1WI和ADC图)合成性能最高,SSIM为86.29%±4.30。合成CBV图联合标准MRI可提高胶质瘤分级、预后预测及肿瘤复发与治疗反应鉴别诊断的AUC。

要点

  • 三维编码器-解码器网络以T1WI、增强T1WI和ADC图为输入时合成CBV性能最高,SSIM为86.29%±4.30。
  • 两名神经放射科医师对合成CBV图的平均定性评分为2.63分(4分Likert量表)。
  • 合成CBV图联合标准MRI可提高胶质瘤分级、预后预测及复发与治疗反应鉴别的AUC。

核心结论

  • GAN图像到图像转换技术可从标准MRI扫描生成准确的合成CBV图,可用于改善脑肿瘤的临床评估。

研究设计与样本

  • 回顾性研究,共纳入756例MRI检查,包含bookend DSC MRI生成的定量CBV图;训练两种算法(特征一致性生成对抗网络和仅用平均绝对误差损失的三维编码器-解码器网络)合成CBV图;使用多中心数据集(4个外部和1个内部)评估临床价值。

诊断标准与关键数值

  • 以bookend技术DSC MRI生成的定量CBV图为参考标准;合成性能以结构相似性指数(SSIM)定量评价,三维编码器-解码器网络(输入T1WI、增强T1WI和ADC图)SSIM为86.29%±4.30;两名神经放射科医师采用四点Likert量表定性评分,合成CBV图平均评分为2.63。

临床应用与阅片要点

  • 合成CBV图联合标准MRI可提高胶质瘤分级(标准MRI AUC 0.707 vs 联合CBV AUC 0.857,z=15.17,P<.001)、胶质瘤预后预测(标准MRI AUC 0.654 vs 联合CBV AUC 0.793,z=9.62,P<.001)、胶质瘤复发与治疗反应鉴别(标准MRI AUC 0.778 vs 联合CBV AUC 0.853,z=4.86,P<.001)及脑转移瘤复发与治疗反应鉴别(标准MRI AUC 0.749 vs 联合CBV AUC 0.857,z=6.13,P<.001)的AUC。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Cerebral blood volume (CBV) maps derived from dynamic susceptibility contrast-enhanced (DSC) MRI are useful but not commonly available in clinical scenarios. Purpose To test image-to-image translation techniques for generating CBV maps from standard MRI sequences of brain tumors using the bookend technique DSC MRI as ground-truth references. Materials and Methods A total of 756 MRI examinations, including quantitative CBV maps produced from bookend DSC MRI, were included in this retrospective study. Two algorithms, the feature-consistency generative adversarial network (GAN) and three-dimensional encoder-decoder network with only mean absolute error loss, were trained to synthesize CBV maps. The performance of the two algorithms was evaluated quantitatively using the structural similarity index (SSIM) and qualitatively by two neuroradiologists using a four-point Likert scale. The clinical value of combining synthetic CBV maps and standard MRI scans of brain tumors was assessed in several clinical scenarios (tumor grading, prognosis prediction, differential diagnosis) using multicenter data sets (four external and one internal). Differences in diagnostic and predictive accuracy were tested using the z test. Results The three-dimensional encoder-decoder network with T1-weighted images, contrast-enhanced T1-weighted images, and apparent diffusion coefficient maps as the input achieved the highest synthetic performance (SSIM, 86.29% ± 4.30). The mean qualitative score of the synthesized CBV maps by neuroradiologists was 2.63. Combining synthetic CBV with standard MRI improved the accuracy of grading gliomas (standard MRI scans area under the receiver operating characteristic curve [AUC], 0.707; standard MRI scans with CBV maps AUC, 0.857; z = 15.17; P < .001), prediction of prognosis in gliomas (standard MRI scans AUC, 0.654; standard MRI scans with CBV maps AUC, 0.793; z = 9.62; P < .001), and differential diagnosis between tumor recurrence and treatment response in gliomas (standard MRI scans AUC, 0.778; standard MRI scans with CBV maps AUC, 0.853; z = 4.86; P < .001) and brain metastases (standard MRI scans AUC, 0.749; standard MRI scans with CBV maps AUC, 0.857; z = 6.13; P < .001). Conclusion GAN image-to-image translation techniques produced accurate synthetic CBV maps from standard MRI scans, which could be used for improving the clinical evaluation of brain tumors. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Branstetter in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Wang B, Pan Y, Xu S, et al. Quantitative Cerebral Blood Volume Image Synthesis from Standard MRI Using Image-to-Image Translation for Brain Tumors. Radiology. 2023. PMID: 37581504. doi:10.1148/radiol.222471

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。