文献速递神经MR

多发性硬化患者血清神经丝轻链与T2病灶体积的相关性强于与T2病灶数量的相关性

Serum neurofilament light chain is more strongly associated with T2 lesion volume than with number of T2 lesions in patients with multiple sclerosis.
PubMed 文献 · Eur J Radiol · 2023-07-31

研究纳入52例临床孤立综合征/复发缓解型多发性硬化患者,比较脑T2病灶总体积与病灶数量同血清及脑脊液神经丝轻链、胶质纤维酸性蛋白的相关性。结果显示血清神经丝轻链与病灶体积的相关性(r=0.6,p<0.001)强于与病灶数量的相关性(r=0.4,p<0.01),两者比较z=-2.0,p<0.05;脑脊液神经丝轻链与两者均呈中度正相关(r=0.5,p<0.01);磁共振指标与胶质纤维酸性蛋白无显著关联。

要点

  • 血清神经丝轻链与T2病灶体积相关性(r=0.6,p<0.001)强于与病灶数量相关性(r=0.4,p<0.01)。
  • 脑脊液神经丝轻链与T2病灶数量及体积均呈中度正相关(r=0.5,p<0.01)。
  • 磁共振病灶指标与胶质纤维酸性蛋白水平无显著关联。

核心结论

  • 研究提示血清神经丝轻链与T2病灶体积的关联强于与T2病灶数量的关联。

研究设计与样本

  • 共纳入52例临床孤立综合征/复发缓解型多发性硬化患者,在神经影像检查时评估3D DIR/FLAIR序列上半自动勾画的脑T2病灶总体积、病灶数量、血清及脑脊液生物标志物和临床参数。

诊断标准与关键数值

  • 血清神经丝轻链与T2病灶体积:r=0.6,p<0.001。
  • 血清神经丝轻链与T2病灶数量:r=0.4,p<0.01。
  • 两者相关系数比较:z=-2.0,p<0.05。
  • 脑脊液神经丝轻链与T2病灶数量及体积:r=0.5,p<0.01。
  • 磁共振病灶指标与胶质纤维酸性蛋白水平无显著关联。

临床应用与阅片要点

  • 作者认为,提高全自动病灶体积分割工具的稳健性和准确性可加速其进入临床常规和试验。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: MR imaging provides information on the number and extend of focal lesions in multiple sclerosis (MS) patients. This study explores whether total brain T2 lesion volume or lesion number shows a better correlation with serum and cerebrospinal fluid (CSF) biomarkers of disease activity.

MATERIALS AND METHODS: In total, 52 patients suffering from clinically isolated syndrome (CIS)/relapsing-remitting multiple sclerosis (RRMS) were assessed including MRI markers (total brain T2 lesion volume semi-automatically outlined on 3D DIR/FLAIR sequences, number of lesions), serum and CSF biomarkers at the time of neuroimaging (neurofilament light chain (NfL), glial fibrillary acidic protein (GFAP)), and clinical parameters. After log-transformation and partial correlations adjusted for the covariates patients' age, BMI, EDSS-score and diagnosis, the Fisher's r-to-Z transformation was used to compare different correlation coefficients.

RESULTS: The correlation between lesion volume and serum NfL (r = 0.6, p < 0.001) was stronger compared to the association between the number of T2 lesions and serum NfL (r = 0.4, p < 0.01) (z = -2.0, p < 0.05). With regard to CSF NfL, there was a moderate, positive relationship for both number of T2 lesions and lesion volume (r = 0.5 respectively, p < 0.01). We found no significant association between MRI markers and GFAP levels.

CONCLUSION: Our findings suggest that there is a stronger association between serum NfL and T2 lesion volume, than there is between serum NfL and T2 lesion number. Improving robustness and accuracy of fully-automated lesion volume segmentation tools can expedite implementation into clinical routine and trials.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wenger KJ, Hoelter MC, Yalachkov Y, et al. Serum neurofilament light chain is more strongly associated with T2 lesion volume than with number of T2 lesions in patients with multiple sclerosis. Eur J Radiol. 2023. PMID: 37549559. doi:10.1016/j.ejrad.2023.111019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。