文献速递神经MR

MP2RAGE 7T序列在多发性硬化颈髓病灶中的贡献

Contribution of the MP2RAGE 7T Sequence in MS Lesions of the Cervical Spinal Cord.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-08-10

17例多发性硬化患者分别在3T和7T接受扫描,比较优化MAGNIMS方案与不同分辨率MP2RAGE序列对颈髓病灶的检出。共检出55个病灶,两种7T MP2RAGE序列各检出51个(92.7%),高于3T优化MAGNIMS方案的41个(74.5%)和3T各向同性MP2RAGE的35个(63.6%)。结论认为7T MP2RAGE序列较3T序列检出更多病灶,各向同性与各向异性采集表现相当。

要点

  • 两种7T MP2RAGE序列各检出51个颈髓病灶(92.7%),为四组中最高。
  • 3T优化MAGNIMS方案检出41个(74.5%),3T各向同性MP2RAGE检出35个(63.6%)。
  • 7T各向同性与各向异性MP2RAGE序列的病灶检出表现相当。

核心结论

  • 7T MP2RAGE序列较3T各序列检出更多颈髓病灶,各向同性与各向异性采集表现相当,超高分辨率7T序列有助于多发性硬化颈髓病灶的识别与勾画。

研究设计与样本

  • 研究纳入17例多发性硬化患者,在同一批患者中于3T和7T分别扫描;3T采用包含轴位T2*WI梯度回波序列的MAGNIMS优化方案及0.9 mm各向同性3D MP2RAGE序列,7T采用0.7 mm各向同性和0.3 mm面内分辨率各向异性3D MP2RAGE序列;每个数据集由放射科医生、神经科医生和神经科学家共识判读。

关键影像表现/征象

  • 共检出55个颈髓病灶,四组序列可见病灶绝对数差异有统计学意义(线性混合效应方差分析,P = .020)。
  • 两种7T MP2RAGE序列各检出51个病灶(占总数的92.7%),为检出最高的序列。
  • 3T优化MAGNIMS方案检出41个病灶(74.5%),3T各向同性MP2RAGE序列检出35个病灶(63.6%)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The detection of spinal cord lesions in patients with MS is challenging. Recently, the 3D MP2RAGE sequence demonstrated its usefulness at 3T. Benefiting from the high spatial resolution provided by ultra-high-field MR imaging systems, we aimed to evaluate the contribution of the 3D MP2RAGE sequence acquired at 7T for the detection of MS lesions in the cervical spine.

MATERIALS AND METHODS: Seventeen patients with MS participated in this study. They were examined at both 3T and 7T. The MR imaging examination included a Magnetic Imaging in MS (MAGNIMS) protocol with an axial T2*-WI gradient recalled-echo sequence ("optimized MAGNIMS protocol") and a 0.9-mm isotropic 3D MP2RAGE sequence at 3T, as well as a 0.7-mm isotropic and 0.3-mm in-plane-resolution anisotropic 3D MP2RAGE sequences at 7T. Each data set was read by a consensus of radiologists, neurologists, and neuroscientists. The number of lesions and their topography, as well as the visibility of the lesions from one set to another, were carefully analyzed.

RESULTS: A total of 55 lesions were detected. The absolute number of visible lesions differed among the 4 sequences (linear mixed effect ANOVA, P = .020). The highest detection was observed for the two 7T sequences with 51 lesions each (92.7% of the total). The optimized 3T MAGNIMS protocol and the 3T MP2RAGE isotropic sequence detected 41 (74.5%) and 35 lesions (63.6%), respectively.

CONCLUSIONS: The 7T MP2RAGE sequences detected more lesions than the 3T sets. Isotropic and anisotropic acquisitions performed comparably. Ultra-high-resolution sequences obtained at 7T improve the identification and delineation of lesions of the cervical spinal cord in MS.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Testud B, Fabiani N, Demortière S, et al. Contribution of the MP2RAGE 7T Sequence in MS Lesions of the Cervical Spinal Cord. AJNR Am J Neuroradiol. 2023. PMID: 37562829. doi:10.3174/ajnr.A7964

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。