磁共振影像组学衍生的球形度与脑动静脉畸形癫痫发作相关
该回顾性研究纳入2010至2020年111例幕上脑动静脉畸形患者,按首发癫痫分组,基于TOF-MRA勾画畸形团、T2WI勾画瘤周脑实质行影像组学分析。多因素分析显示低球形度(OR 2012.07,p=.04)和血管生成(OR 5.30,p=.01)与癫痫高风险独立相关;影像组学模型AUC 0.817,优于血管构筑模型0.672。
要点
- 低畸形团球形度与脑动静脉畸形患者癫痫高风险独立相关(OR 2012.07,p=.04)。
- MR影像组学模型诊断癫痫性BAVM的AUC为0.817,优于血管构筑模型的0.672。
- 影像组学或可作为无创、客观评估BAVM癫痫风险的方法。
核心结论
- 低畸形团球形度和血管生成与BAVM患者癫痫高风险相关,MR影像组学工具或可用于无创、客观评估BAVM所致癫痫风险。
研究设计与样本
- 回顾性研究,纳入2010至2020年111例幕上BAVM患者,按首发癫痫表现分组,分析血管造影和MR影像以确定血管构筑,在TOF-MRA上勾画畸形团、T2WI上勾画瘤周脑实质行影像组学分析。
诊断标准与关键数值
- 多因素分析中低球形度OR 2012.07(p=.04)、血管生成OR 5.30(p=.01)与癫痫高风险独立相关;血管构筑模型AUC 0.672,MR影像组学模型AUC 0.817,联合模型AUC 0.794;DCA证实影像组学模型和联合模型具有临床效用。
临床应用与阅片要点
- 作者认为MR影像组学或可作为无创、客观的测量方法用于评估BAVM患者的癫痫风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Angioarchitectural analysis of brain arteriovenous malformations (BAVMs) is qualitative and subject to interpretation. This study quantified the morphology of and signal changes in the nidal and perinidal areas by using MR radiomics and compared the performance of MR radiomics and angioarchitectural analysis in detecting epileptic BAVMs.
MATERIALS AND METHODS: From 2010 to 2020, a total of 111 patients with supratentorial BAVMs were retrospectively included and grouped in accordance with the initial presentation of seizure. Patients' angiograms and MR imaging results were analyzed to determine the corresponding angioarchitecture. The BAVM nidus was contoured on time-of-flight MR angiography images. The perinidal brain parenchyma was contoured on T2-weighted images, followed by radiomic analysis. Logistic regression analysis was performed to determine the independent risk factors for seizure. ROC curve analysis, decision curve analysis (DCA), and calibration curve were performed to compare the performance of angioarchitecture-based and radiomics-based models in diagnosing epileptic BAVMs.
RESULTS: In multivariate analyses, low sphericity (OR: 2012.07, p = .04) and angiogenesis (OR: 5.30, p = .01) were independently associated with a high risk of seizure after adjustment for age, sex, temporal location, and nidal volume. The AUC for the angioarchitecture-based, MR radiomics-based, and combined models was 0.672, 0.817, and 0.794, respectively. DCA confirmed the clinical utility of the MR radiomics-based and combined models.
CONCLUSIONS: Low nidal sphericity and angiogenesis were associated with high seizure risk in patients with BAVMs. MR radiomics-derived tools may be used for noninvasive and objective measurement for evaluating the risk of seizure due to BAVM.
CLINICAL RELEVANCE STATEMENT: Low nidal sphericity was associated with high seizure risk in patients with brain arteriovenous malformation and MR radiomics may be used as a noninvasive and objective measurement method for evaluating seizure risk in patients with brain arteriovenous malformation.
KEY POINTS: • Low nidal sphericity was associated with high seizure risk in patients with brain arteriovenous malformation. • The performance of MR radiomics in detecting epileptic brain arteriovenous malformations was more satisfactory than that of angioarchitectural analysis. • MR radiomics may be used as a noninvasive and objective measurement method for evaluating seizure risk in patients with brain arteriovenous malformation.
引用
- Lin JY, Lu CF, Hu YS, et al. Magnetic resonance radiomics-derived sphericity correlates with seizure in brain arteriovenous malformations. Eur Radiol. 2023. PMID: 37553487. doi:10.1007/s00330-023-09982-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。