指南与共识外周血管儿科影像技术与安全US

遵循共识的B型超声与射频回声跟踪测量儿童颈动脉内中膜厚度的正常值:一项系统综述

Normal pediatric values of carotid artery intima-media thickness measured by B-mode ultrasound and radiofrequency echo tracking respecting the consensus: a systematic review.
指南 / 共识 · Eur Radiol · 2023-08-05

该系统综述依据PRISMA指南,检索至2023年2月的2298篇英文文献,纳入88项B型超声研究(6184名儿童)和6项射频回声跟踪研究(766名儿童)。IMT与年龄无显著关系(P=0.83),性别对IMT无显著影响(B型超声P=0.82,射频P=0.62);IMT具有技术特异性,正常值应按公认共识解读。

要点

  • 无危险因素儿童中IMT与年龄无显著关系(P=0.83),健康男孩与女孩IMT无差异。
  • IMT测量具有技术特异性,正常值应按照公认共识推荐解读。

核心结论

  • 基于所选文献,无法得出男孩与女孩平均IMT存在显著差异的结论,年龄与IMT之间未证实存在关系;IMT具有技术特异性,正常值应按公认共识推荐解读,以应对当前文献中的异质性。

研究设计与样本

  • 系统综述,按PRISMA指南执行,检索2298篇英文文献(起自建库至2023年2月);纳入基于美国心脏协会、欧洲儿科心脏病学协会、Mannheim共识和美国超声心动图学会推荐的B型超声与射频IMT测量研究;对汇总数据进行Meta分析,采用95%置信水平获得IMT的置信区间。

临床应用与阅片要点

  • 作者认为,技术与儿童特异性内中膜厚度测量有助于临床医生和科学家评估儿童动脉粥样硬化风险;正常值应按照公认共识的推荐解读。

局限性

  • 基于所选文献,无法得出男孩与女孩平均IMT存在显著差异的结论。
  • 年龄与IMT之间未证实存在关系。
  • 即使研究遵循官方共识,文献中仍存在异质性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Carotid artery intima-media thickness (IMT) is a sub-clinical radiologic marker of atherosclerosis in children. It is associated with adult-onset vascular disease.

OBJECTIVE: To determine normal pediatric values of IMT from results observed in the literature.

METHODS: Our systematic review was conducted according to PRISMA guidelines. We reviewed 2298 English articles from inception to February 2023. Inclusion criteria included studies evaluating B-mode and radiofrequency (RF)-based IMT measurements based on the American Heart Association, the Association for European Pediatric Cardiology, the Mannheim Consensus, and the American Society of Echocardiography recommendations. A meta-analysis of aggregate data was conducted to obtain the confidence interval (CI) for IMT, using a 95% confidence level.

RESULTS: We obtained 88 B-mode-based IMT measurement studies with 6184 children and six radiofrequency echo-tracking-based studies with 766 children. Mean IMT in the pediatric population was 0.43 mm, 95% [CI] 0,42 to 0.44, using the B-mode technique, and 0.41 mm, 95% [CI] 0.36 to 0.45 using the radiofrequency technique. No significant relationship was detected between IMT and age (p value = 0.83). Finally, no significant effect of sex on IMT was found (p value = 0.82 for B-mode and p value = 0.62 for RF).

CONCLUSION: Based on the studies selected in this literature review, we were unable to conclude that there was a significant difference between the average IMT of boys and girls. No relationship was demonstrated between age and IMT. IMT is technique-specific, and normal values should be interpreted according to recommendations of recognized consensus to counteract the current heterogeneity in literature.

CLINICAL RELEVANCE STATEMENT: Technique and children-specific Intima media thickness measurements help clinicians and scientists to assess the risk of atherosclerosis in children.

KEY POINTS: • Intima-media thickness (IMT) does not correlate with age in children without risk factors. • According to current literature, there is no difference in IMT between healthy boys and girls. • There is heterogeneity, even with studies abiding by the official consensus.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Moretti JB, Michael R, Gervais S, et al. Normal pediatric values of carotid artery intima-media thickness measured by B-mode ultrasound and radiofrequency echo tracking respecting the consensus: a systematic review. Eur Radiol. 2023. PMID: 37542654. doi:10.1007/s00330-023-09994-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。