在1.5T下使用深度学习重建弥散加权成像缩短盆腔MRI采集时间并提高图像质量
这项回顾性单中心研究连续纳入55例患者,在1.5T下比较标准弥散加权成像(DWI)与深度学习重建DWI(DWIDL)的图像质量与采集时间。四名放射科医生用5分Likert量表评估,DWIDL在b=0、b=800 s/mm²及ADC图上的整体图像质量和噪声均显著优于标准DWI(P<.05、P<.001),伪影、病灶可检测性、器官锐利度和诊断信心无显著差异;标准DWI采集时间为2分06秒,DWIDL模拟采集时间为1分12秒。作者结论认为深度学习重建可改善图像质量,模拟结果提示缩短盆腔1.5T弥散加权MRI采集时间是可能的。
要点
- DWIDL在b=0、b=800 s/mm²及ADC图上整体图像质量显著优于标准DWI(P<.05)。
- DWIDL噪声显著少于标准DWI(P<.001),伪影与诊断信心无显著差异。
- 标准DWI采集2分06秒,DWIDL模拟采集1分12秒,提示缩短采集时间可能。
核心结论
- 深度学习图像重建可改善图像质量,模拟结果提示缩短1.5T盆腔弥散加权MRI采集时间是可能的。
研究设计与样本
- 回顾性单中心研究,2022年2月至11月连续纳入55例患者(平均年龄61±13岁,范围27-89岁;男20例、女35例),均行1.5T临床指征MRI并包含标准DWI和深度学习重建DWI,采用b=0和800 s/mm²两个b值并计算ADC图。
诊断标准与关键数值
- 图像质量由四名放射科医生用5分Likert量表(5分为最佳)定性评估整体图像质量、噪声水平、伪影范围、锐利度和诊断信心。
- DWIDL在b=0 s/mm²、b=800 s/mm²和ADC图上的整体图像质量均显著优于标准DWI(P<.05)。
- DWIDL在b=0 s/mm²、b=800 s/mm²和ADC图上的噪声均显著少于标准DWI(P<.001)。
- 伪影、病灶可检测性、器官锐利度和诊断信心在两种DWI间无显著差异(P>.05)。
- 标准DWI采集时间为2分06秒,DWIDL模拟采集时间为1分12秒。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To determine the impact on acquisition time reduction and image quality of a deep learning (DL) reconstruction for accelerated diffusion-weighted imaging (DWI) of the pelvis at 1.5 T compared to standard DWI.
MATERIALS AND METHODS: A total of 55 patients (mean age, 61 ± 13 years; range, 27-89; 20 men, 35 women) were consecutively included in this retrospective, monocentric study between February and November 2022. Inclusion criteria were (1) standard DWI (DWIS) in clinically indicated magnetic resonance imaging (MRI) at 1.5 T and (2) DL-reconstructed DWI (DWIDL). All patients were examined using the institution's standard MRI protocol according to their diagnosis including DWI with two different b-values (0 and 800 s/mm2) and calculation of apparent diffusion coefficient (ADC) maps. Image quality was qualitatively assessed by four radiologists using a visual 5-point Likert scale (5 = best) for the following criteria: overall image quality, noise level, extent of artifacts, sharpness, and diagnostic confidence. The qualitative scores for DWIS and DWIDL were compared with the Wilcoxon signed-rank test.
RESULTS: The overall image quality was evaluated to be significantly superior in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .05). The extent of noise was evaluated to be significantly less in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .001). No significant differences were found regarding artifacts, lesion detectability, sharpness of organs, and diagnostic confidence (P > .05). Acquisition time for DWIS was 2:06 minutes, and simulated acquisition time for DWIDL was 1:12 minutes.
CONCLUSION: DL image reconstruction improves image quality, and simulation results suggest that a reduction in acquisition time for diffusion-weighted MRI of the pelvis at 1.5 T is possible.
引用
- Herrmann J, Benkert T, Brendlin A, et al. Shortening Acquisition Time and Improving Image Quality for Pelvic MRI Using Deep Learning Reconstruction for Diffusion-Weighted Imaging at 1.5 T. Acad Radiol. 2023. PMID: 37500416. doi:10.1016/j.acra.2023.06.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。