基于全自动深度学习量化流程准确测量磁共振帕金森指数
研究提出全自动深度学习流程,用nnUNet分割脑干、HRNet识别中脑与脑桥分界及小脑中脚端点,并在斜冠状面测量小脑上脚宽度以计算磁共振帕金森指数(MRPI)。在训练集和三个外部数据集上平均绝对百分比误差分别为17.21%、18.17%、20.83%和22.83%,前两个外部数据集上两位阅片者间平均绝对百分比误差为11.31%;该流程显著优于一种代表性传统方法(p < 0.001)。
要点
- 全自动流程可测量MRPI,训练集平均绝对百分比误差17.21%。
- 三个外部验证集平均绝对百分比误差分别为18.17%、20.83%、22.83%。
- 前两个外部数据集阅片者间平均绝对百分比误差为11.31%。
核心结论
- 所提出的全自动流程能较准确地预测MRPI,与人工测量具有可比性。
研究设计与样本
- 研究论文;使用400张T1加权磁共振图像训练nnUNet和HRNet模型,采用五折交叉验证评估训练数据集性能,并在三个外部数据集上评估;其中两个外部数据集由两位阅片者手动测量MRPI值。
诊断标准与关键数值
- MRPI定义为脑桥面积与中脑面积比值乘以小脑中脚宽度与小脑上脚宽度比值。
- 训练数据集平均绝对百分比误差为17.21%。
- 三个外部验证数据集平均绝对百分比误差分别为18.17%、20.83%和22.83%。
- 前两个外部验证数据集阅片者间平均绝对百分比误差为11.31%。
临床应用与阅片要点
- 该自动测量工具可分析大量磁共振图像,提高帕金森叠加综合征诊断效率、减少临床医生工作量并减少人为因素对诊断的影响。
局限性
- 训练数据集平均绝对百分比误差为17.21%,高于前两个外部验证数据集阅片者间平均绝对百分比误差11.31%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aims at a fully automatic pipeline for measuring the magnetic resonance parkinsonism index (MRPI) using deep learning methods.
METHODS: MRPI is defined as the product of the pons area to the midbrain area ratio and the middle cerebellar peduncle (MCP) width to the superior cerebellar peduncle (SCP) width ratio. In our proposed pipeline, we first used nnUNet to segment the brainstem and then employed HRNet to identify two key boundary points so as to sub-divide the whole brainstem into midbrain and pons. HRNet was also employed to predict the MCP endpoints for measuring the MCP width. Finally, we segmented the SCP on an oblique coronal plane and calculated its width. A total of 400 T1-weighted magnetic resonance images (MRIs) were used to train the nnUNet and HRNet models. Five-fold cross-validation was conducted to evaluate our proposed pipeline's performance on the training dataset. We also evaluated the performance of our proposed pipeline on three external datasets. Two of them had two raters manually measuring the MRPI values, providing insights into automatic accuracy versus inter-rater variability.
RESULTS: We obtained average absolute percentage errors (APEs) of 17.21%, 18.17%, 20.83%, and 22.83% on the training dataset and the three external validation datasets, while the inter-rater average APE measured on the first two external validation datasets was 11.31%. Our proposed pipeline significantly improved the MRPI quantification accuracy over a representative state-of-the-art traditional approach (p < 0.001).
CONCLUSION: The proposed automatic pipeline can accurately predict MRPI that is comparable with manual measurement.
CLINICAL RELEVANCE STATEMENT: This study presents an automated magnetic resonance parkinsonism index measurement tool that can analyze large amounts of magnetic resonance images, enhance the efficiency of Parkinsonism-Plus syndrome diagnosis, reduce the workload of clinicians, and minimize the impact of human factors on diagnosis.
KEY POINTS: • We propose an automatic pipeline for measuring the magnetic resonance parkinsonism index from magnetic resonance images. • The effectiveness of the proposed pipeline is successfully established on multiple datasets and comparisons with inter-rater measurements. • The proposed pipeline significantly outperforms a state-of-the-art quantification approach, being much closer to ground truth.
引用
- Sun F, Lyu J, Jian S, et al. Accurate measurement of magnetic resonance parkinsonism index by a fully automatic and deep learning quantification pipeline. Eur Radiol. 2023. PMID: 37480547. doi:10.1007/s00330-023-09979-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。