文献速递神经儿科影像MR

儿童烟雾病前循环血运重建术后动态磁敏感对比增强灌注MRI监测后循环灌注变化

Monitoring Posterior Cerebral Perfusion Changes With Dynamic Susceptibility Contrast-Enhanced Perfusion MRI After Anterior Revascularization Surgery in Pediatric Moyamoya Disease.
PubMed 文献 · Korean J Radiol · 2023-01-01

回顾性纳入73例完成前循环血运重建术后随访期间出现新发症状的儿童烟雾病患者,行DSC灌注MRI,分为新确认大脑后动脉受累的PCA狭窄组30例和无PCA受累组43例;PCA狭窄组PCA及PCA-MCA交界区nTTP和MTT显著延迟、nCBV增高,TTPPCA判别PCA狭窄的ROC曲线下面积最高(0.895)。

要点

  • 前循环血运重建术后随访中出现视觉障碍等症状的儿童烟雾病患者需关注PCA狭窄。
  • PCA狭窄组PCA及PCA-MCA交界区nTTP、MTT显著延迟,nCBV增高。
  • TTPPCA判别PCA狭窄的ROC曲线下面积最高(0.895;95%CI 0.803-0.986)。

核心结论

  • nTTP可有效诊断PCA狭窄,DSC灌注MRI可能成为监测烟雾病患者PCA狭窄的有价值工具。

研究设计与样本

  • 回顾性纳入2016年1月至2020年12月期间完成前循环血运重建术后随访中出现新发临床症状的73例烟雾病患者(年龄12.2±6.1岁),行DSC灌注MRI,使用NordicICE软件分析MCA、PCA及PCA-MCA交界区灌注参数。

关键影像表现/征象

  • PCA狭窄组平均随访时间为前循环血运重建术后5.3年,视觉障碍为常见症状。
  • PCA狭窄组PCA及PCA-MCA交界区nCBV增高,nTTP和MTT值较无PCA狭窄组显著延迟。

诊断标准与关键数值

  • TTPPCA与PCA狭窄独立相关(OR=6.745;95%CI 2.665-17.074;P<0.001)。
  • CBVPCA-MCA与PCA狭窄独立相关(OR=1.567;95%CI 1.021-2.406;P=0.040)。
  • TTPPCA判别PCA狭窄的ROC曲线下面积最高(0.895;95%CI 0.803-0.986)。

临床应用与阅片要点

  • 对前循环血运重建术后随访中出现视觉障碍等症状的儿童烟雾病患者,可关注DSC灌注MRI上PCA及PCA-MCA交界区的nTTP改变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine whether dynamic susceptibility contrast-enhanced (DSC) perfusion magnetic resonance imaging (MRI) can be used to evaluate posterior cerebral circulation in pediatric patients with moyamoya disease (MMD) who underwent anterior revascularization.

MATERIALS AND METHODS: This study retrospectively included 73 patients with MMD who underwent DSC perfusion MRI (age, 12.2 ± 6.1 years) between January 2016 and December 2020, owing to recent-onset clinical symptoms during the follow-up period after completion of anterior revascularization. DSC perfusion images were analyzed using a dedicated software package (NordicICE; Nordic NeuroLab) for the middle cerebral artery (MCA), posterior cerebral artery (PCA), and posterior border zone between the two regions (PCA-MCA). Patients were divided into two groups; the PCA stenosis group included 30 patients with newly confirmed PCA involvement, while the no PCA stenosis group included 43 patients without PCA involvement. The relationship between DSC perfusion parameters and PCA stenosis, as well as the performance of the parameters in discriminating between groups, were analyzed.

RESULTS: In the PCA stenosis group, the mean follow-up duration was 5.3 years after anterior revascularization, and visual disturbances were a common symptom. Normalized cerebral blood volume was increased, and both the normalized time-to-peak (nTTP) and mean transit time values were significantly delayed in the PCA stenosis group compared with those in the no PCA stenosis group in the PCA and PCA-MCA border zones. TTPPCA (odds ratio [OR] = 6.745; 95% confidence interval [CI] = 2.665-17.074; P < 0.001) and CBVPCA-MCA (OR = 1.567; 95% CI = 1.021-2.406; P = 0.040) were independently associated with PCA stenosis. TTPPCA showed the highest receiver operating characteristic curve area in discriminating for PCA stenosis (0.895; 95% CI = 0.803-0.986).

CONCLUSION: nTTP can be used to effectively diagnose PCA stenosis. Therefore, DSC perfusion MRI may be a valuable tool for monitoring PCA stenosis in patients with MMD.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Seo YS, Lee S, Choi YH, et al. Monitoring Posterior Cerebral Perfusion Changes With Dynamic Susceptibility Contrast-Enhanced Perfusion MRI After Anterior Revascularization Surgery in Pediatric Moyamoya Disease. Korean J Radiol. 2023. PMID: 37500579. doi:10.3348/kjr.2023.0035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。