文献速递骨肌MR

大型患者队列中冈上肌腱腱膜扩张与肱二头肌腱异常的二维和三维MR关节造影描述

The 2D and 3D MR arthrographic description of aponeurotic expansion of supraspinatus tendon and biceps tendon anomaly in a large patient cohort.
PubMed 文献 · Skeletal Radiol · 2023-07-31

回顾性分析2010年5月至2022年1月700例肩关节MR关节造影,在3D VIBE序列上识别冈上肌腱腱膜扩张(AEST)并分型,检出率9%(63/700),最常见为1型(39/63),最常见远端止点为肱骨颈中段LHBT腱鞘(31/63);仅10例肱二头肌腱异常(4例缺如、6例纵裂)。

要点

  • 3D VIBE MR关节造影可显示AEST,检出率9%(63/700),最常见为1型。
  • AEST最常见走行为前正中线,最常见止点为肱骨颈中段LHBT腱鞘(31/63)。
  • 肱二头肌腱异常仅10例:4例缺如、6例纵裂,需与AEST鉴别。

核心结论

  • 二维和高分辨率三维MR关节造影可显示肱二头肌沟周围解剖细节,有助于鉴别肱二头肌腱异常与AEST。

研究设计与样本

  • 回顾性研究,纳入2010年5月至2022年1月700例肩关节MR关节造影,采用3D脂肪抑制T1加权VIBE序列行直接MR关节造影。

关键影像表现/征象

  • AEST在3D VIBE MR关节造影图像上于肩关节前部被识别,共63例(9%)。
  • AEST最常见关节造影类型为1型,63例中39例。
  • AEST最常见走行为前正中线,最常见远端止点为肱骨颈中段LHBT腱鞘,63例中31例。
  • 肱二头肌腱异常共10例,包括4例肱二头肌腱缺如和6例纵裂。

诊断标准与关键数值

  • 基于形态将AEST分为四型:肱二头肌沟滑膜表面无腱性厚度或滑膜内腱样结构;肱二头肌滑膜薄而平的腱性厚度≥1 mm;卵圆形腱性结构小于相邻肱二头肌腱一半大小;卵圆形腱性结构大于相邻肱二头肌腱一半大小;以及卵圆形腱性结构大于相邻肱二头肌腱。
  • 基于起点和止点将腱膜扩张分为三型:近端滑车区、肱骨颈中段区和远端肌腱连接处区。
  • 根据与肱二头肌滑膜的关系将AEST分为三型:滑膜内、滑膜外和跨滑膜。

临床应用与阅片要点

  • 在3D VIBE MR关节造影上,AEST倾向于位于肱二头肌滑膜的前正中线和前内侧部分,走行可为滑膜内、滑膜外或跨滑膜,并具有三种不同止点类型。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To describe the aponeurotic expansion of supraspinatus tendon (AEST) and biceps tendon abnormalities with magnetic resonance (MR) arthrographic examinations and determine their prevalence in patients, we performed a high-resolution 3D direct MR arthrography.

MATERIALS AND METHODS: This was a retrospective study of 700 shoulder MR arthrograms performed between May 2010 and January 2022. Extension in the coronal plane of an AEST on 3D fat-suppressed T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography was identified. Based on its morphology, the AEST on MR arthrography was divided into four subtypes: absence of tendinous thickness in the bicipital synovial surface or intra-synovial tendon-like structure in the bicipital groove, thin and flat tendinous thickness ≥1 mm of bicipital synovium, oval tendinous structure less than half the size of the adjacent biceps tendon, oval tendinous structure more than half the size of the adjacent biceps tendon, and oval tendinous structure larger than the adjacent biceps tendon. Based on its origin and termination, aponeurotic expansions can be divided into three subtypes: proximal pulley zone, middle humeral neck zone, and distal myotendinous junction zone. Association with the biceps synovium of the AEST was categorized into three types: intra-synovial, extra-synovial, and trans-synovial.

RESULTS: An AEST in the anterior shoulder joint in 3D VIBE MR arthrography images was identified in 63 (9%) of 700 arthrograms. The most common arthrographic type of AEST was type 1-this was detected in 39 of 63 patients. The most common course type of the AEST was anteriorly midline. The most common distal insertion type was at the tenosynovial sheath of the long head of the biceps tendon (LHBT) in the middle humeral neck zone-this was detected in 31 of 63 patients. There were only 10 MR arthrograms biceps tendon abnormality, including 4 biceps agenesis and 6 split ruptures.

CONCLUSION: A 2D and high-resolution 3D MR arthrography can demonstrate the anatomical detail around the bicipital groove and facilitate the differentiation between a biceps tendon anomaly and an AEST. On high-resolution 3D MR arthrographic images, the AEST tends to be in the anterior midline and anteromedial portions of the biceps synovium with intra-synovial, extra-synovial, and trans-synovial courses and its three different insertion types.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Guclu D, Ogul H, Unlu EN, et al. The 2D and 3D MR arthrographic description of aponeurotic expansion of supraspinatus tendon and biceps tendon anomaly in a large patient cohort. Skeletal Radiol. 2023. PMID: 37522946. doi:10.1007/s00256-023-04409-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。