文献速递乳腺MR

磁共振成像特征及肿瘤至乳头距离诊断乳腺癌乳头乳晕复合体受累的准确性:系统评价与Meta分析

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis.
PubMed 文献 · Korean J Radiol · 2023-01-01

该系统评价与Meta分析纳入15项研究共4002个乳腺病灶,评估术前乳腺MRI特征及肿瘤至乳头距离(TND)对隐匿性乳头乳晕复合体(NAC)受累的诊断准确性。结果显示,与NAC相连的汇总敏感度71%、特异度94%,单侧NAC强化分别为58%和97%,非肿块强化类型分别为55%和83%,肿块大小(>20 mm)分别为88%和58%;TND的SROC曲线下面积为0.799,TND 11.5 mm达到预设特异度85%时敏感度64%,12.3 mm达到预设特异度83%时敏感度65%。作者认为与NAC相连和单侧NAC强化可能有助于预测隐匿性NAC受累,使用TND时应考虑合适的截断值。

要点

  • 与NAC相连诊断NAC受累的汇总敏感度71%、特异度94%。
  • 单侧NAC强化汇总敏感度58%、特异度97%,特异度高而敏感度低。
  • 肿块大小>20 mm汇总敏感度88%、特异度58%,阳性时需结合其他征象。

核心结论

  • 与NAC相连和单侧NAC强化可能有助于预测乳腺癌隐匿性NAC受累;使用TND时需考虑合适的截断值以达到期望的诊断性能。

研究设计与样本

  • 系统评价与Meta分析,检索MEDLINE、Embase和Cochrane数据库截至2022年3月20日的文献,排除临床明显NAC受累或接受新辅助化疗的患者,纳入15项研究共4002个乳腺病灶,采用QUADAS-2工具评价研究质量,由两名评价者独立评估,采用随机效应模型计算汇总敏感度、特异度及SROC曲线。

关键影像表现/征象

  • 与NAC相连:汇总敏感度71%(95%CI 58-81),特异度94%(95%CI 91-96)。
  • 单侧NAC强化:汇总敏感度58%(95%CI 45-70),特异度97%(95%CI 95-99)。
  • 非肿块强化类型:汇总敏感度55%(95%CI 46-64),特异度83%(95%CI 75-88)。
  • 肿块大小>20 mm:汇总敏感度88%(95%CI 68-96),特异度58%(95%CI 40-75)。

诊断标准与关键数值

  • TND诊断NAC受累的SROC曲线下面积为0.799。
  • TND 11.5 mm达到预设特异度85%,对应敏感度64%。
  • TND 12.3 mm达到预设特异度83%,对应敏感度65%。
  • MRI特征包括与NAC相连、单侧NAC强化、非肿块强化类型、肿块大小>20 mm及TND。

临床应用与阅片要点

  • 阅片时可关注与NAC相连和单侧NAC强化,二者可能有助于预测隐匿性NAC受累。
  • 使用TND评估NAC受累时,需考虑合适的截断值以达到期望的诊断性能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer.

MATERIALS AND METHODS: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values.

RESULTS: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%.

CONCLUSION: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Byon JH, Hwang S, Choi H, et al. Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis. Korean J Radiol. 2023. PMID: 37500575. doi:10.3348/kjr.2022.0846

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。