文献速递乳腺MR

使用连续时间随机游走MR扩散模型评估乳腺癌恶性程度、预后因素和分子亚型

Evaluation of breast cancer malignancy, prognostic factors and molecular subtypes using a continuous-time random-walk MR diffusion model.
PubMed 文献 · Eur J Radiol · 2023-07-22

本回顾性研究纳入85例患者(70个恶性、18个良性病灶),用3.0T MRI多b值DWI拟合连续时间随机游走(CTRW)模型,比较其参数与ADC在良恶性鉴别及与病理预后因素、分子亚型关联中的价值。结果显示恶性病灶ADC、Dm、α、β均显著低于良性(P<0.05),CTRW三参数联合AUC最高(0.833)、敏感度最佳(94.3%),β与ER、PR、Ki-67表达相关(P<0.05)。

要点

  • 恶性病灶的ADC、Dm、α、β均显著低于良性病灶(P<0.05)。
  • CTRW三参数(Dm、α、β)联合鉴别恶性状态的AUC最高为0.833,敏感度最佳为94.3%。
  • β与ER、PR、Ki-67表达显著相关(P<0.05),高Ki-67者Dm和ADC显著更低(P<0.05)。

核心结论

  • CTRW参数可作为无创定量影像标志物用于评估乳腺病灶。

研究设计与样本

  • 回顾性研究,纳入85例患者(70个恶性病灶、18个良性病灶),行3.0T MRI检查,DWI采集16个b值拟合CTRW模型。

诊断标准与关键数值

  • 恶性病灶ADC、Dm、α、β均显著低于良性病灶(P<0.05)。
  • CTRW三参数(Dm、α、β)联合鉴别恶性状态的AUC为0.833,敏感度为94.3%。
  • ER、PR阳性者β显著低于阴性者(P<0.05)。
  • Ki-67高表达者Dm和ADC值显著更低(P<0.05)。
  • β与ER、PR、Ki-67表达显著相关(P<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the continuous-time random-walk (CTRW) model's diagnostic value in breast lesions and to explore the associations between the CTRW parameters and breast cancer pathologic factors.

METHOD: This retrospective study included 85 patients (70 malignant and 18 benign lesions) who underwent 3.0T MRI examinations. Diffusion-weighted images (DWI) were acquired with 16b-values to fit the CTRW model. Three parameters (Dm, α, and β) derived from CTRW and apparent diffusion coefficient (ADC) from DWI were compared among the benign/malignant lesions, molecular prognostic factors, and molecular subtypes by Mann-Whitney U test. Spearman correlation was used to evaluate the associations between the parameters and prognostic factors. The diagnostic performance was assessed by the area under the receiver operating characteristic curve (AUC) based on the diffusion parameters.

RESULTS: All parameters, ADC, Dm, α, and β were significantly lower in the malignant than benign lesions (P < 0.05). The combination of all the CTRW parameters (Dm, α, and β) provided the highest AUC (0.833) and the best sensitivity (94.3%) in differentiating malignant status. And the positive status of estrogen receptor (ER) and progesterone receptor (PR) showed significantly lower β compared with the negative counterparts (P < 0.05). The high Ki-67 expression produced significantly lower Dm and ADC values (P < 0.05). Additionally, combining multiple CTRW parameters improved the performance of diagnosing molecular subtypes of breast cancer. Moreover, Spearman correlations analysis showed that β produced significant correlations with ER, PR and Ki-67 expression (P < 0.05).

CONCLUSIONS: The CTRW parameters could be used as non-invasive quantitative imaging markers to evaluate breast lesions.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chang H, Wang D, Li Y, et al. Evaluation of breast cancer malignancy, prognostic factors and molecular subtypes using a continuous-time random-walk MR diffusion model. Eur J Radiol. 2023. PMID: 37506477. doi:10.1016/j.ejrad.2023.111003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。