文献速递乳腺MR

基于深度学习的新型扩散加权成像序列在1.5 T乳腺MRI中的应用

Novel deep-learning-based diffusion weighted imaging sequence in 1.5 T breast MRI.
PubMed 文献 · Eur J Radiol · 2023-06-25

回顾性分析55例在1.5 T行乳腺DWI的女性患者,比较标准DWI序列与深度学习重建图像(仅用部分采集平均值重建以缩短采集时间)。深度学习重建使采集时间缩短40%,在保持对比度、伪影水平和诊断信心的同时改善噪声与锐利度;ADC及b50、b800信号强度值及病灶评估无差异。

要点

  • 深度学习重建DWI较标准DWI采集时间缩短40%,图像噪声与锐利度改善,对比度、伪影与诊断信心相当。
  • 标准与深度学习图像的ADC值(p=0.955)、b50值(p=0.070)、b800值(p=0.415)信号强度无差异。
  • ADC与DWI序列病灶数目(均p=1.000)及DWI、ADC病灶直径(p=0.961;0.972)评估无差异。

核心结论

  • 新型深度学习重建算法显著缩短乳腺DWI采集时间,同时改善锐利度、降低噪声,并保持与标准序列相当的图像质量、伪影、对比度和诊断信心,且不影响可量化参数。

研究设计与样本

  • 回顾性分析55例在1.5 T行乳腺DWI的女性患者,将原始数据用深度学习重建算法在部分采集平均值上重建以缩短采集时间,比较临床使用的标准DWI序列(DWIStd)与深度学习重建图像(DWIDL)。

关键影像表现/征象

  • DWIDL较DWIStd噪声改善、锐利度提高,同时保持对比度、伪影水平和诊断信心。
  • b800与ADC图像由两名放射科医师采用1至5分Likert量表评分,5分为理想图像质量。
  • 在同一位置放置感兴趣区测量信号强度,标准与深度学习图像的ADC值(p=0.955)、b50值(p=0.070)、b800值(p=0.415)无差异。

诊断标准与关键数值

  • 图像质量采用Likert量表1至5分评分,5分为理想图像质量,由两名放射科医师对b800和ADC图像评分。
  • ADC值标准与深度学习图像比较p=0.955,b50值p=0.070,b800值p=0.415。
  • 病灶数目ADC与DWI均p=1.000,病灶直径DWI p=0.961;0.972、ADC p=0.961;0.972。

临床应用与阅片要点

  • DWIDL可在缩短40%采集时间的同时保持与标准DWI相当的图像质量、伪影、对比度和诊断信心。
  • DWIDL不影响ADC、b50、b800信号强度值及病灶数目与直径评估,可量化参数与标准序列可比。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aimed to assess the technical feasibility, the impact on image quality, and the acquisition time (TA) of a new deep-learning-based reconstruction algorithm in diffusion weighted imaging (DWI) of breast magnetic resonance imaging (MRI).

METHODS: Retrospective analysis of 55 female patients who underwent breast DWI at 1.5 T. Raw data were reconstructed using a deep-learning (DL) reconstruction algorithm on a subset of the acquired averages, therefore a reduction of TA. Clinically used standard DWI sequence (DWIStd) and the DL-reconstructed images (DWIDL) were compared. Two radiologists rated the image quality of b800 and ADC images, using a Likert-scale from 1 to 5 with 5 being considered perfect image quality. Signal intensities were measured by placing a region of interest (ROI) at the same position in both sequences.

RESULTS: TA was reduced by 40 % in DWIDL, compared to DWIStd, DWIDL improved noise and sharpness while maintaining contrast, the level of artifacts, and diagnostic confidence. There were no differences regarding the signal intensity values of the apparent diffusion coefficient (ADC), (p = 0.955), b50-values (p = 0.070) and b800-values (p = 0.415) comparing standard and DL-imaging. Lesion assessment showed no differences regarding the number of lesions in ADC and DWI (both p = 1.000) and regarding the lesion diameter in DWI (p = 0.961;0.972) and ADC (p = 0.961;0.972).

CONCLUSIONS: The novel deep-learning-based reconstruction algorithm significantly reduces TA in breast DWI, while improving sharpness, reducing noise, and maintaining a comparable level of image quality, artifacts, contrast, and diagnostic confidence. DWIDL does not influence the quantifiable parameters.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wessling D, Gassenmaier S, Olthof SC, et al. Novel deep-learning-based diffusion weighted imaging sequence in 1.5 T breast MRI. Eur J Radiol. 2023. PMID: 37481831. doi:10.1016/j.ejrad.2023.110948

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。