文献速递妇产影像儿科影像神经US

单胎妊娠胎儿前复合体的神经超声测量

Neurosonographic Measurements of the Fetal Anterior Complex in Singleton Pregnancies.
PubMed 文献 · J Ultrasound Med · 2023-07-25

在低风险妊娠中经腹超声于轴位经室平面和冠状位经尾状核平面测量胎儿前复合体,包括侧脑室指数、侧脑室前角宽度和透明隔腔宽度,共395例胎儿;五个参数均随孕龄呈二次函数变化,建立均值与标准差模型及百分位图,模型拟合良好,观察者内与观察者间一致性极佳,所建参考范围可用于临床。

要点

  • 于轴位经室平面和冠状位经尾状核平面测量侧脑室指数、前角宽度和透明隔腔宽度。
  • 近探头侧与远探头侧大脑半球分别定义,五个参数均随孕龄呈二次函数变化。
  • 已建立各参数均值与标准差模型及百分位图,模型拟合良好,一致性极佳。

核心结论

  • 已建立泰国胎儿前复合体包括侧脑室指数、前角宽度和透明隔腔宽度在轴位经室平面与冠状位经尾状核平面的参考范围,可供临床使用。

研究设计与样本

  • 前瞻性招募低风险妊娠,经腹超声于轴位经室平面和冠状位经尾状核平面测量胎儿前复合体,共395例胎儿,采用回归分析构建均值与标准差随孕龄变化的最佳拟合模型。

关键影像表现/征象

  • 远探头侧大脑半球定义为 downside hemisphere,近探头侧定义为 upside hemisphere,分别测量 downside/upside 侧脑室指数、downside/upside 前角宽度及透明隔腔宽度共五个变量。
  • 所有参数随孕龄呈二次函数变化。
  • 基于孕龄的各数值 Z 分数分布用于评估模型拟合度,所有模型拟合良好。

诊断标准与关键数值

  • 构建了五个参数预测均值与标准差随孕龄变化的模型及百分位图。
  • 观察者内与观察者间可靠性系数显示所有数值一致性极佳。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To construct reference ranges of the fetal cerebral anterior complex, including ventricular index (VI), anterior horn of lateral ventricle width (AW), and cavum septi pellucidi (CSP) width, as a function of gestational age (GA), in Thai fetuses.

METHODS: Low-risk pregnancies were recruited to measure fetal anterior complex on axial transventricular and coronal transcaudate planes using transabdominal ultrasound. The downside and upside hemisphere were defined as cerebral hemisphere located distal and proximal to the transducer, respectively. The five variables, downside/upside VI, downside/upside AW and CSP width, were measured from each fetus. Best-fit models in predicting mean and standard deviation for each value as a function of GA were constructed, using regression analysis. Distributions of Z-scores of all values based on GA were created to evaluate the fitness of models. Intraclass correlation coefficients were used to assess inter-/intraobserver variability.

RESULTS: A total of 395 fetuses were measured for anterior complex. All parameters changed with GA with quadratic function. The models for predicting means and standard deviation of the five parameters as well as percentile charts were created. All models were proven well-fitted. The intra-/interobserver reliability coefficients of all values showed excellent agreement.

CONCLUSION: The reference ranges of the fetal anterior complex, including VI, AW, and CSP, in axial transventricular and coronal transcaudate planes have been established and available for clinical use.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Kaewnin J, Dulyaphat W, Tongsong T, et al. Neurosonographic Measurements of the Fetal Anterior Complex in Singleton Pregnancies. J Ultrasound Med. 2023. PMID: 37490581. doi:10.1002/jum.16307

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。