使用焦点法获取切面以提高胎儿生物测量的可重复性
研究纳入80例孕18至37周单胎非畸形孕妇,由两名不同经验超声医师盲法各采集四次头围、腹围和股骨长切面,比较标准图像参照与焦点法获取切面的可重复性。焦点法使观察者内和观察者间95%一致性界限均缩小,且不依赖医师资历和切面类型,作者建议将该方法用于临床实践和培训。
要点
- 焦点法定义:头围切面取透明隔腔,腹围切面取脐静脉三分之二处,股骨长切面取骨干两端之一。
- 焦点法较标准技术改善观察者内可重复性(95%LoA <4% vs <6%)。
- 焦点法较标准技术改善观察者间可重复性(95%LoA <7% vs <8%)。
核心结论
- 使用焦点法获取切面可改善胎儿生物测量的可重复性,且不依赖超声医师经验;作者建议将该方法应用于临床实践和胎儿生物测量培训项目。
研究设计与样本
- 前瞻性研究纳入80例孕18至37周单胎非畸形妊娠孕妇,于伦敦大学学院医院(University College London Hospital)进行;两名经验不同(培训中或拥有超过3000次扫描经验)的超声医师盲法互相独立,各采集四次头围、腹围和股骨长切面,第一组图像参照标准图像获取,第二组使用焦点法获取;采用Bland-Altman图评估观察者内和观察者间可重复性,报告平均差及95%一致性界限(LoA)的绝对值和百分比。
诊断标准与关键数值
- 焦点法定义为每个切面中一个独特的胎儿解剖标志:头围切面为透明隔腔,腹围切面为脐静脉三分之二处,股骨长切面为骨干两端之一;识别后保持焦点在视野内,沿x、y、z三轴旋转探头以获取相关切面。总体可重复性良好,所有95%LoA <8%;观察者内比较中焦点法95%LoA <4% vs 标准技术<6%,观察者间比较中焦点法95%LoA <7% vs 标准技术<8%。
临床应用与阅片要点
- 作者建议将焦点法应用于临床实践和胎儿生物测量培训项目;该方法改善可重复性且不依赖超声医师资历和所获取切面。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the reproducibility of ultrasound measurements of fetal biometry using a 'focus point' to assist the acquisition of the relevant plane.
METHODS: This was a study of 80 women with a singleton non-anomalous pregnancy who attended University College London Hospital, London, UK, between 18 and 37 weeks' gestation. Planes to measure head circumference (HC), abdominal circumference (AC) and femur length (FL) were obtained four times by two different sonographers with different levels of experience, who were blinded to one another; the first set of images was obtained with reference to a standard image, and the second set of images was obtained using the focus point technique. The focus point was defined as a unique fetal anatomical landmark in each plane (cavum septi pellucidi for HC, two-thirds of the umbilical vein for AC and one of the two extremities of the diaphysis for FL). Once identified, the focus point was maintained in view while the sonographer rotated the probe along three axes (x, y, z) to acquire the relevant plane. Sonographers were either in training or had > 3000 scans worth of experience. Intra- and interobserver reproducibility were assessed using Bland-Altman plots, and absolute values and percentages for mean difference and 95% limits of agreement (LoA) were reported.
RESULTS: Overall reproducibility was good, with all 95% LoA < 8%. Reproducibility was improved by use of the focus point compared with the standard technique for both intraobserver comparison (95% LoA, < 4% vs < 6%) and interobserver comparison (95% LoA, < 7% vs < 8%). These findings were independent of sonographer seniority and plane acquired.
CONCLUSIONS: Reproducibility of fetal biometry assessment is improved with use of the focus point for plane acquisition, regardless of sonographer experience. We propose that this method should be implemented in clinical practice and training programs in fetal biometry. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Vignola S, Donadono V, Cavalli C, et al. Use of focus point for plane acquisition to improve reproducibility in fetal biometry. Ultrasound Obstet Gynecol. 2024. PMID: 37519218. doi:10.1002/uog.27436