心脏MRI晚期钆增强图像上不同心肌瘢痕定量阈值对植入型心律转复除颤器患者的预后价值
这项回顾性两中心观察性队列研究纳入374例缺血性或非缺血性心肌病患者,在植入ICD前接受心脏MRI检查,比较不同瘢痕定量阈值对恰当ICD放电和死亡的预测价值。中位随访61个月,有LGE者恰当ICD放电或死亡发生率高于无LGE者(37.5% vs 26.6%,log-rank P=0.04);多变量分析中各种瘢痕定量阈值均非显著预测因子,而灰区范围是独立预测因子(每1g调整HR=1.025,95%CI 1.008-1.043,P=0.005)。
要点
- 有LGE者恰当ICD放电或死亡发生率高于无LGE者(37.5% vs 26.6%,log-rank P=0.04)。
- 各种瘢痕定量阈值均非死亡或恰当ICD放电的显著预测因子。
- 灰区范围是独立预测因子(每1g调整HR=1.025,95%CI 1.008-1.043,P=0.005)。
核心结论
- LGE存在与恰当ICD放电或死亡发生率较高相关;各种瘢痕定量技术均未预测结局,但梗死性和非缺血性瘢痕中的灰区均为独立预测因子,可能细化风险分层。
研究设计与样本
- 回顾性两中心观察性队列研究,纳入374例连续合格患者(平均年龄61岁±13,平均左心室射血分数32%±14,二级预防62.7%),缺血性或非缺血性心肌病患者在ICD植入前接受心脏MRI。
关键影像表现/征象
- LGE先由视觉判定,再由盲法心脏MRI阅片者使用高于正常心肌平均信号的不同SD、全宽半最大值和手动阈值进行定量。
- 中间信号「灰区」计算为不同SD之间的差值。
诊断标准与关键数值
- 有LGE者恰当ICD放电或死亡发生率为37.5%,无LGE者为26.6%(log-rank P=0.04),中位随访61个月。
- 多变量分析中各种瘢痕定量阈值均非死亡或恰当ICD放电的显著预测因子。
- 灰区范围每1g调整HR=1.025(95%CI 1.008,1.043;P=0.005),无论是否存在缺血性心脏病(交互作用P=0.57)。
- 包含灰区(2 SD至4 SD之间)的模型判别能力最高。
临床应用与阅片要点
- 视觉判定LGE存在与否可用于识别恰当ICD放电或死亡风险较高的患者。
- 灰区范围(2 SD至4 SD之间)是独立预测因子,作者认为可能细化风险分层。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the predictive value of different myocardial scar quantification thresholds using cardiac MRI for appropriate implantable cardioverter defibrillator (ICD) shock and mortality.
MATERIALS AND METHODS: In this retrospective, two-center observational cohort study, patients with ischemic or nonischemic cardiomyopathy underwent cardiac MRI prior to ICD implantation. Late gadolinium enhancement (LGE) was first determined visually and then quantified by blinded cardiac MRI readers using different SDs above the mean signal of normal myocardium, full-width half-maximum, and manual thresholding. The intermediate signal "gray zone" was calculated as the differences between different SDs.
RESULTS: Among 374 consecutive eligible patients (mean age, 61 years ± 13 [SD]; mean left ventricular ejection fraction, 32% ± 14; secondary prevention, 62.7%), those with LGE had a higher rate of appropriate ICD shock or death than those without (37.5% vs 26.6%, log-rank P = .04) over a median follow-up of 61 months. In multivariable analysis, none of the thresholds for quantifying scar was a significant predictor of mortality or appropriate ICD shock, while the extent of gray zone was an independent predictor (adjusted hazard ratio per 1 g = 1.025; 95% CI: 1.008, 1.043; P = .005) regardless of the presence or absence of ischemic heart disease (P interaction = .57). Model discrimination was highest for the model incorporating the gray zone (between 2 SD and 4 SD).
CONCLUSION: Presence of LGE was associated with a higher rate of appropriate ICD shock or death. Although none of the scar quantification techniques predicted outcomes, the gray zone both in infarct and nonischemic scar was an independent predictor and may refine risk stratification.Keywords: MRI, Scar Quantification, Implantable Cardioverter Defibrillator, Sudden Cardiac Death Supplemental material is available for this article. © RSNA, 2023.
引用
- Shalmon T, Hamad FMD, Jimenez-Juan L, et al. Prognostic Value of Different Thresholds for Myocardial Scar Quantification on Cardiac MRI Late Gadolinium Enhancement Images in Patients Receiving Implantable Cardioverter Defibrillators. Radiol Cardiothorac Imaging. 2023. PMID: 37404790. doi:10.1148/ryct.210247
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。