文献速递心血管MR

基于MR特征追踪的心肌应变测量:性别、年龄、场强和厂商的影响

Myocardial Strain Measurements Derived From MR Feature-Tracking: Influence of Sex, Age, Field Strength, and Vendor.
PubMed 文献 · JACC Cardiovasc Imaging · 2023-07-19

该系统综述与Meta分析纳入44项研究共3359名健康成人,汇总了心脏磁共振特征追踪(CMR-FT)测量的四腔室心肌应变正常值,并发现FT厂商是左室整体纵向应变、左室整体环向应变、左房主动应变和右室整体纵向应变异质性的显著来源,而性别、年龄和MR厂商对正常值无影响。

要点

  • 健康成人左室整体纵向应变汇总均值为-18.4%(95%CI:-19.2%至-17.6%)。
  • FT厂商是左室整体纵向应变、左室整体环向应变、左房主动应变和右室整体纵向应变异质性的显著来源。
  • 性别、年龄和MR厂商对CMR-FT应变正常值无影响。

核心结论

  • 本研究展示了健康受试者四腔室CMR-FT应变参数的正常值,FT厂商的差异导致了左室整体纵向应变、左室整体环向应变、左房主动应变和右室整体纵向应变的异质性,而性别、年龄和MR厂商对正常值无影响。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Embase和Scopus,纳入44项研究共3359名健康成人,采用随机效应模型汇总所有应变参数的均值,并进行亚组分析和Meta回归以识别变异来源。

诊断标准与关键数值

  • 左室整体纵向应变汇总均值为-18.4%(95%CI:-19.2%至-17.6%),左室整体径向应变为43.7%(95%CI:40.0%-47.4%),左室整体环向应变为-21.4%(95%CI:-22.3%至-20.6%);左房整体纵向应变(对应总应变、被动应变和主动应变)分别为34.9%(95%CI:29.6%-40.2%)、21.3%(95%CI:16.6%-26.1%)和14.3%(95%CI:11.8%-16.8%);右室整体纵向应变和右房整体纵向总应变分别为-24.0%(95%CI:-25.8%至-22.1%)和36.3%(95%CI:15.5%-57.0%)。

临床应用与阅片要点

  • Meta回归识别场强(P < 0.001;I2 = 98.6%)和FT厂商(P < 0.001;I2 = 98.5%)为左室整体纵向应变异质性的显著混杂因素;左房主动应变变异与地区分布(P < 0.001;I2 = 97.3%)和FT厂商(P < 0.001;I2 = 97.4%)相关;FT厂商差异归因于左室整体环向应变和右室整体纵向应变的变异(P = 0.02;I2 = 98.8%和P = 0.01;I2 = 93.8%)。

局限性

  • 左室整体纵向应变异质性I2 = 98.6%。
  • FT厂商对左室整体纵向应变异质性I2 = 98.5%。
  • 左房主动应变地区分布异质性I2 = 97.3%。
  • 左房主动应变FT厂商异质性I2 = 97.4%。
  • 左室整体环向应变FT厂商异质性I2 = 98.8%,右室整体纵向应变FT厂商异质性I2 = 93.8%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Cardiac magnetic resonance feature tracking (CMR-FT) is a novel technique for assessing myocardial deformation and dysfunction. However, a comprehensive assessment of normal values of strain parameters in all 4 cardiac chambers using different vendors is lacking.

OBJECTIVES: This study aimed to characterize the normal values for myocardial strain in all 4 cardiac chambers and identify factors that contribute to variations in FT strain through a systematic review and meta-analysis of the CMR-FT published reports.

METHODS: The investigators searched PubMed, Embase, and Scopus for myocardial strains of all 4 chambers measured by CMR-FT in healthy adults. The pooled means of all strain parameters were generated using a random-effects model. Subgroup analyses and meta-regressions were performed to identify the sources of variations.

RESULTS: This meta-analysis included 44 studies with a total of 3,359 healthy subjects. The pooled means of left ventricular global longitudinal strain (LV-GLS), LV global radial strain, and LV global circumferential strain (GCS) were -18.4% (95% CI: -19.2% to -17.6%), 43.7% (95% CI: 40.0%-47.4%), and -21.4% (95% CI: -22.3% to -20.6%), respectively. The pooled means of left atrial (LA)-GLS (corresponding to total strain, passive strain, and active strain) were 34.9% (95% CI: 29.6%-40.2%), 21.3% (95% CI: 16.6%-26.1%) and 14.3% (95% CI: 11.8%-16.8%), respectively. The pooled means of right ventricular (RV)-GLS and right atrial global longitudinal total strain were -24.0% (95% CI: -25.8% to -22.1%) and 36.3% (95% CI: 15.5%-57.0%), respectively. Meta-regression identified field strength (P < 0.001; I2 = 98.6%) and FT vendor (P < 0.001; I2 = 98.5%) as significant confounders contributing to heterogeneity of LV-GLS. The variations of LA-GLSactive were associated with regional distribution (P < 0.001; I2 = 97.3%) and FT vendor (P < 0.001; I2 = 97.4%). Differences in FT vendor were attributed to variations of LV-GCS and RV-GLS (P = 0.02; I2 = 98.8% and P = 0.01; I2 = 93.8%).

CONCLUSIONS: This study demonstrated the normal values of CMR-FT strain parameters in all 4 cardiac chambers in healthy subjects. Differences in FT vendor contributed to the heterogeneity of LV-GLS, LV-GCS, LA-GLSactive, and RV-GLS, whereas sex, age, and MR vendor had no effect on the normal values of CMR-FT strain measurements.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Yang W, Xu J, Zhu L, et al. Myocardial Strain Measurements Derived From MR Feature-Tracking: Influence of Sex, Age, Field Strength, and Vendor. JACC Cardiovasc Imaging. 2023. PMID: 37480906. doi:10.1016/j.jcmg.2023.05.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。