基于深度学习的胸片肺结节自动检测:与背景肺部状况、结节特征及位置的关系
本研究纳入388例临床疑似肺癌患者,评估商用深度学习自动检测(DLAD)软件在胸片肺结节检测中的独立性能。DLAD对322个可见结节检出222个,敏感度0.689,假阳性率0.168;对小、亚实性及与重叠结构相关的结节检出敏感度显著降低,背景肺部评分与检出关系不明确。
要点
- DLAD对胸片肺结节的敏感度为0.689,假阳性率0.168。
- DLAD对小、亚实性及与重叠结构相关的结节检出敏感度显著降低。
- 结节可见度评分与DLAD检出敏感度呈正相关。
核心结论
- DLAD独立检测肺结节的敏感度为0.689、假阳性率为0.168;理解DLAD特性对辅助解读胸片至关重要。
研究设计与样本
- 单中心研究,纳入2020年6月至2022年5月临床疑似肺癌、在CT扫描前后一个月内行胸片检查的患者388例;以两位放射科医生参考CT标注的边界框为参考标准;使用商用深度学习自动检测软件EIRL Chest X-ray Lung Nodule。
关键影像表现/征象
- DLAD对322个手动评估可见结节中的222个检出,敏感度0.689,假阳性率0.168。
- DLAD对小、亚实性及与重叠结构相关的结节检出敏感度显著降低。
- 结节可见度评分与DLAD检出敏感度呈正相关。
- 背景肺部评分与DLAD检出的关系不明确。
诊断标准与关键数值
- DLAD检测肺结节的敏感度为0.689,假阳性率为0.168。
- 小、亚实性及与重叠结构相关的结节DLAD检出敏感度显著降低。
- 结节可见度评分与DLAD检出敏感度呈正相关。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Computer-aided diagnosis (CAD), which assists in the interpretation of chest radiographs, is becoming common. However, few studies have evaluated the benefits and pitfalls of CAD in the real world. This study aimed to evaluate the independent performance of commercially available deep learning-based automatic detection (DLAD) software, EIRL Chest X-ray Lung Nodule, in a cohort that included patients with background pulmonary abnormalities often encountered in clinical situations.
METHODS: Patients with clinically suspected lung cancer for whom chest radiography was performed within a month before or after CT scan between June 2020 and May 2022 in our institution were enrolled. The reference standard was created using a bounding box annotated by two radiologists with reference to the CT. The visibility score, characteristics, location of the pulmonary nodules, presence of overlapping structures or pulmonary disease, and background lung score were manually determined.
RESULTS: We included 388 patients. The DLAD software detected 222 of the 322 nodules visible on manual evaluation, with a sensitivity of 0.689 and a false-positive rate of 0.168. The detectability of the DLAD software was significantly lower for small and subsolid and nodules with overlapping structures. The visibility score and sensitivity of detection by the DLAD software were positively correlated. The relationship between the background lung score and detection by the DLAD software was unclear.
CONCLUSION: The standalone performance of DLAD in detecting pulmonary nodules exhibited a sensitivity of 0.689 and a false-positive rate of 0.168. Understanding the characteristics of DLAD is crucial when interpreting chest radiographs with the assistance of the DLAD.
引用
- Ueno M, Yoshida K, Takamatsu A, et al. Deep learning-based automatic detection for pulmonary nodules on chest radiographs: The relationship with background lung condition, nodule characteristics, and location. Eur J Radiol. 2023. PMID: 37499478. doi:10.1016/j.ejrad.2023.111002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。