文献速递胸部CT

利用肺功能检查数据评估肺癌患者基于个体化生物力学模型生成的肺部四维CT应力图

Assessing four-dimensional CT stress maps derived from patient-specific biomechanical models of the lung with pulmonary function test data in lung cancer patients.
PubMed 文献 · Br J Radiol · 2023-07-04

本研究回顾性分析25例肺癌患者的治疗前四维CT和肺功能检查数据,利用生物力学模型可变形图像配准生成肺部应力图,并与肺功能指标对比。结果显示全肺平均应力与FEV1占预计值百分比及FEV1/FVC均呈显著强相关(R分别为0.833和0.805,p均<0.001),鉴别肺功能正常与异常的AUC为0.94,最佳截断值为510.8 Pa。研究表明基于生物力学模型可变形图像配准的应力图有潜力准确评估肺功能。

要点

  • 全肺平均应力与FEV1占预计值百分比呈显著强相关(R=0.833,p<0.001)。
  • 全肺平均应力与FEV1/FVC呈显著强相关(R=0.805,p<0.001)。
  • 鉴别肺功能正常与异常的全肺应力AUC为0.94,最佳截断值510.8 Pa。

核心结论

  • 基于生物力学模型可变形图像配准的肺部应力图通过与肺功能检查数据对比,显示出准确评估肺功能的潜力。

研究设计与样本

  • 回顾性分析25例肺癌患者治疗前四维CT和肺功能检查数据,采用四维CT和生物力学模型可变形图像配准获取肺部应力图,以肺功能检查指标诊断阻塞性肺疾病。

诊断标准与关键数值

  • 全肺平均应力与FEV1占预计值百分比显著强相关(R=0.833,p<0.001),与FEV1/FVC显著强相关(R=0.805,p<0.001);鉴别肺功能正常与异常的全肺应力AUC为0.94,最佳截断值为510.8 Pa。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aims to retrospectively compare the stress map of the lung with pulmonary function test (PFT) results in lung cancer patients and to evaluate the potential of the stress map as an imaging biomarker for chronic obstructive pulmonary disease (COPD).

METHODS: 25 lung cancer patients with pre-treatment four-dimensional CT (4DCT) and PFT data were retrospectively analysed. PFT metrics were used to diagnose obstructive lung disease. For each patient, forced expiratory volume in 1 s (FEV1 % predicted) and the ratio of FEV1 and forced vital capacity (FEV1/FVC) were recorded. 4DCT and biomechanical model-deformable image registration (BM-DIR) were used to obtain the lung stress map. The relationship between the mean of the total lung stress and PFT data was evaluated, and the COPD classification grade was also evaluated.

RESULTS: The mean values of the total lung stress and FEV1 % predicted showed a significant strong correlation [R = 0.833, (p < 0.001)]. The mean values and FEV1/FVC showed a significant strong correlation [R = 0.805, (p < 0.001)]. For the total lung stress, the area under the curve and the optimal cut-off value were 0.94 and 510.8 Pa for the classification of normal or abnormal lung function, respectively.

CONCLUSION: This study has demonstrated the potential of lung stress maps based on BM-DIR to accurately assess lung function by comparing them with PFT data.

ADVANCES IN KNOWLEDGE: The derivation of stress map directly from 4DCT is novel method. The BM-DIR-based lung stress map can provide an accurate assessment of lung function.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Shiinoki T, Fujimoto K, Kawazoe Y, et al. Assessing four-dimensional CT stress maps derived from patient-specific biomechanical models of the lung with pulmonary function test data in lung cancer patients. Br J Radiol. 2023. PMID: 37393529. doi:10.1259/bjr.20221149

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。