基于生成对抗网络在不同CT协议和厂商间进行图像转换:对间质性肺病区域病变模式量化准确性和变异性的影响
本研究纳入150例间质性肺病患者共350层薄层CT,使用RouteGAN将不同厂商、剂量和重建核的CT图像转换为目标风格(厂商A、标准剂量、锐利核),再用深度学习软件量化间质性肺病。转换后总体异常量化的重叠准确度提高,纤维化评分、蜂窝影和网状的Dice相似系数显著增加,而磨玻璃影、实变和肺气肿无显著变化或略降低;放射科医师对转换后CT的量化准确性评分显著更高且变异更小。
要点
- RouteGAN转换可提高不同扫描参数和厂商CT在深度学习量化间质性肺病时的总体异常重叠准确度。
- 转换后纤维化评分、蜂窝影和网状的Dice相似系数显著提高,磨玻璃影、实变和肺气肿无显著变化或略降低。
- 放射科医师对转换后CT的量化准确性评分显著更高且变异更小。
核心结论
- 使用RouteGAN进行CT转换可提高不同扫描参数和厂商CT图像在深度学习量化间质性肺病时的准确性和变异性。
研究设计与样本
- 研究纳入接受薄层CT的间质性肺病患者,将来自四家厂商(A-D)、标准或低辐射剂量、锐利或中等核的不匹配CT图像按采集条件分为1-7组,用RouteGAN将2-7组转换为目标CT风格(1组:厂商A、标准剂量、锐利核),并用深度学习软件(Aview,Coreline Soft)对原始和转换后CT进行间质性肺病量化。
诊断标准与关键数值
- 以放射科医师手动量化为参考,用Dice相似系数(DSC)和像素级重叠准确度指标分析量化准确性;五位放射科医师用10分视觉评分系统评估量化准确性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software.
MATERIALS AND METHODS: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system.
RESULTS: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT.
CONCLUSION: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.
引用
- Hwang HJ, Kim H, Seo JB, et al. Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease. Korean J Radiol. 2023. PMID: 37500581. doi:10.3348/kjr.2023.0088
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。