基于深度学习的CT重建核转换在间质性肺疾病定量分析中的可重复性影响
回顾性纳入194例间质性肺疾病或间质性肺异常患者,比较B30f、B50f、B60f三种重建核对方格状影、蜂窝影及纤维化评分自动定量的影响。不同重建核导致各模式定量范围差异,深度学习核转换后测量变异性降低,从B50f转换的B60f图像纤维化评分与原始B60f几乎等效。
要点
- 不同重建核会影响间质性肺疾病各模式的自动定量范围。
- B30f图像低估、B50f图像高估方格状影和蜂窝影。
- 深度学习核转换可降低不同重建核间的定量测量变异性。
核心结论
- 间质性肺疾病的CT定量分析受不同重建核影响,但基于深度学习的核转换有效降低了测量变异性,提高了定量的可重复性。
研究设计与样本
- 回顾性纳入2022年6月至2022年9月接受平扫高分辨率CT的间质性肺疾病或间质性肺异常患者194例,图像以B30f、B50f、B60f三种核重建,以B60f为定量参考标准,用商业软件定量各间质性肺疾病模式和纤维化评分,以组内相关系数(ICC)和Bland-Altman法评估核转换对测量变异性的影响。
关键影像表现/征象
- 不同重建核导致各间质性肺疾病模式定量范围出现差异。
- 方格状影和蜂窝影在B30f图像上被低估、在B50f图像上被高估。
诊断标准与关键数值
- 核转换后测量变异性降低:平均差值从-2.0至3.9%变为-0.3至0.4%,95%一致性界限从[-5.0, 12.7]变为[-2.7, 2.1]。
- 从B50f转换的B60f图像纤维化评分与原始B60f几乎等效:ICC为1.000,平均差值0.0,95%一致性界限[-0.4, 0.4]。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The effect of different computed tomography (CT) reconstruction kernels on the quantification of interstitial lung disease (ILD) has not been clearly demonstrated. The study aimed to investigate the effect of reconstruction kernels on the quantification of ILD on CT and determine whether deep learning-based kernel conversion can reduce the variability of automated quantification results between different CT kernels.
MATERIALS AND METHODS: Patients with ILD or interstitial lung abnormality who underwent noncontrast high-resolution CT between June 2022 and September 2022 were retrospectively included. Images were reconstructed with three different kernels: B30f, B50f, and B60f. B60f was regarded as the reference standard for quantification, and B30f and B50f images were converted to B60f images using a deep learning-based algorithm. Each disease pattern of ILD and the fibrotic score were quantified using commercial software. The effect of kernel conversion on measurement variability was estimated using intraclass correlation coefficient (ICC) and Bland-Altman method.
RESULTS: A total of 194 patients were included in the study. Application of different kernels induced differences in the quantified extent of each pattern. Reticular opacity and honeycombing were underestimated on B30f images and overestimated on B50f images. After kernel conversion, measurement variability was reduced (mean difference, from -2.0 to 3.9 to -0.3 to 0.4%, and 95% limits of agreement [LOA], from [-5.0, 12.7] to [-2.7, 2.1]). The fibrotic score for converted B60f from B50f images was almost equivalent to the original B60f (ICC, 1.000; mean difference, 0.0; and 95% LOA [-0.4, 0.4]).
CONCLUSION: Quantitative CT analysis of ILD was affected by the application of different kernels, but deep learning-based kernel conversion effectively reduced measurement variability, improving the reproducibility of quantification.
引用
- Ahn Y, Lee SM, Nam Y, et al. Deep Learning-Based CT Reconstruction Kernel Conversion in the Quantification of Interstitial Lung Disease: Effect on Reproducibility. Acad Radiol. 2023. PMID: 37516583. doi:10.1016/j.acra.2023.06.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。