初次肺癌筛查中偶发发现报告方式的差异及其与临床医师评估的关系
回顾性分析2015至2018年明尼阿波利斯退伍军人医疗系统901例初次肺癌筛查患者的健康记录,量化偶发发现的分布、频率与临床意义,并分析报告特征与后续评估的关系。偶发发现极为常见(93.9%),放射科医师对显著偶发发现的报告差异较大,放射科医师建议、高风险发现及在印象中报告与显著偶发发现被处理的相关性增加。
要点
- 初次肺癌筛查中偶发发现极为常见(93.9%),平均每例扫描2.6个偶发发现。
- 放射科医师对显著偶发发现的报告差异大:印象中至少提及一个显著偶发发现的比例为24%至78%,S修饰符使用率为0%至51%。
- 放射科医师建议、高风险发现及在印象中报告与显著偶发发现被处理的相关性增加。
核心结论
- 放射科医师在肺癌筛查中对偶发发现的报告存在差异;进一步标准化显著偶发发现的报告可能改善这一过程,同时实现需要时生成适当检查与减少低价值医疗的目标。
研究设计与样本
- 回顾性研究,纳入2015至2018年明尼阿波利斯退伍军人医疗系统初次肺癌筛查患者901例,复核健康记录中的 demographics、肺部CT筛查报告与数据系统编码、偶发发现及后续临床评估;采用混合效应模型分析结局。
诊断标准与关键数值
- 偶发发现若可能需要任何随访则视为潜在显著;高风险显著偶发发现为可能恶性;显著偶发发现被处理为主要结局。偶发发现93.9%,平均每例扫描2.6个(n=2,296);786个偶发发现(34.2%)被认为可能为显著偶发发现,其中58个(7.4%)为高风险;222个(28.2%)被临床医师处理,其中104个(13.2%)接受了检查。放射科医师建议(调整OR 4.67;95%CI 2.23-9.76)、高风险发现(调整OR 4.35;95%CI 1.81-10.45)及在印象中报告(调整OR 2.58;95%CI 1.28-5.18)与显著偶发发现被处理的 odds 增加相关。
临床应用与阅片要点
- 作者认为进一步标准化显著偶发发现的报告可能改善这一过程,同时实现需要时生成适当检查与减少低价值医疗的目标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study was to quantify the distribution, frequency, and clinical significance of incidental findings (IFs) on initial lung cancer screening (LCS) and the association of report characteristics with subsequent assessment.
METHODS: Health records of patients undergoing initial LCS from 2015 to 2018 in the Minneapolis VA Health Care System were retrospectively reviewed for demographics, Lung CT Screening Reporting & Data System coding, IFs, and subsequent clinical assessment. IFs were considered potentially significant if they were likely to require any follow-up. High-risk significant IFs (SIFs) were potentially malignant. The primary outcome was the SIF being addressed. Outcomes were analyzed using a mixed-effects model.
RESULTS: Patients (n = 901) were primarily male (94.1%) smokers (62.1%) with a mean age of 65.2 years. IFs were extremely common (93.9%), with an average of 2.6 IFs per scan (n = 2,296). Seven hundred eighty-six IFs (34.2%) were deemed likely SIFs, of which 58 (7.4%) were high risk. Two hundred twenty-two (28.2%) were addressed by clinicians, of which 104 (13.2%) underwent testing. Reporting of SIFs varied among radiologists, with at least one SIF in the impression in 24% to 78% of low-dose CT studies with the S modifier, used to indicate the presence of a SIF, applied to 0% to 51% of reports. In the mutually adjusted model, radiologist recommendation (adjusted odds ratio [OR], 4.67; 95% confidence interval [CI], 2.23-9.76), high-risk finding (adjusted OR, 4.35; 95% CI, 1.81-10.45), and reporting in the impression (adjusted OR, 2.58; 95% CI, 1.28-5.18) were associated with increased odds of the SIF's being addressed.
CONCLUSIONS: Radiologists vary in their reporting of IFs on LCS. Further standardization of reporting of SIFs may improve this process, with the simultaneous goals of generating appropriate testing when needed and minimizing low-value care.
引用
- Melzer AC, Atoma B, Fabbrini AE, et al. Variation in Reporting of Incidental Findings on Initial Lung Cancer Screening and Associations With Clinician Assessment. J Am Coll Radiol. 2023. PMID: 37516160. doi:10.1016/j.jacr.2023.03.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。