文献速递胸部儿科影像CTMR

利用超短回波时间肺部MRI生成高分辨率合成CT:在囊性纤维化中的初步评估

Generating High-Resolution Synthetic CT from Lung MRI with Ultrashort Echo Times: Initial Evaluation in Cystic Fibrosis.
PubMed 文献 · Radiology · 2023-01-01

本研究为回顾性研究,纳入2018年1月至2022年12月六家机构中同日接受超短回波时间(UTE)MRI与CT的囊性纤维化(CF)患者,用生成对抗网络(GAN)由UTE MRI生成合成CT,并评估其图像质量与临床适用性。结果显示合成CT与真实CT在CF相关肺部改变显示上几乎完全一致(组内相关系数≥0.92),图像质量优于UTE MRI。

要点

  • 合成CT与真实CT的Bhalla评分一致性几乎完美(组内相关系数≥0.92)。
  • 合成CT的信噪比与真实CT相似(中位数88 vs 88,P=0.96)。
  • 合成CT噪声评分低于真实CT(中位数26 vs 42,P<0.001),伪影评分最低(中位数0,P<0.001)。

核心结论

  • 由UTE MRI生成的合成CT图像在显示CF相关肺部改变方面与真实CT几乎完全一致,且图像质量优于UTE MRI。

研究设计与样本

  • 回顾性研究,纳入2018年1月至2022年12月六家机构中同日接受UTE MRI与CT的CF患者;训练集82例(平均年龄21岁±11,男42例),测试集28例(平均年龄18岁±11,男16例),外部数据集46例(平均年龄20岁±11,男24例);采用二维GAN算法以配对MRI与CT层面训练,并与外部数据集一同测试。

关键影像表现/征象

  • 测试集中合成CT的表观对比噪声比中位数303(IQR 221-382),高于UTE MRI的9.3(IQR 6.6-35)(P<0.001)。
  • 合成CT与真实CT的表观信噪比中位数相似(88 [IQR 84-92] vs 88 [IQR 86-91];P=0.96)。
  • 合成CT噪声评分中位数26(IQR 22-30),低于真实CT的42(IQR 32-50)(P<0.001)。
  • 合成CT伪影评分中位数0(IQR 0-0),为最低水平(P<0.001)。

诊断标准与关键数值

  • 两名阅片者评估CF相关结构异常并据此计算临床Bhalla评分,合成CT与真实CT的Bhalla评分组内相关系数≥0.92。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Lung MRI with ultrashort echo times (UTEs) enables high-resolution and radiation-free morphologic imaging; however, its image quality is still lower than that of CT. Purpose To assess the image quality and clinical applicability of synthetic CT images generated from UTE MRI by a generative adversarial network (GAN). Materials and Methods This retrospective study included patients with cystic fibrosis (CF) who underwent both UTE MRI and CT on the same day at one of six institutions between January 2018 and December 2022. The two-dimensional GAN algorithm was trained using paired MRI and CT sections and tested, along with an external data set. Image quality was assessed quantitatively by measuring apparent contrast-to-noise ratio, apparent signal-to-noise ratio, and overall noise and qualitatively by using visual scores for features including artifacts. Two readers evaluated CF-related structural abnormalities and used them to determine clinical Bhalla scores. Results The training, test, and external data sets comprised 82 patients with CF (mean age, 21 years ± 11 [SD]; 42 male), 28 patients (mean age, 18 years ± 11; 16 male), and 46 patients (mean age, 20 years ± 11; 24 male), respectively. In the test data set, the contrast-to-noise ratio of synthetic CT images (median, 303 [IQR, 221-382]) was higher than that of UTE MRI scans (median, 9.3 [IQR, 6.6-35]; P < .001). The median signal-to-noise ratio was similar between synthetic and real CT (88 [IQR, 84-92] vs 88 [IQR, 86-91]; P = .96). Synthetic CT had a lower noise level than real CT (median score, 26 [IQR, 22-30] vs 42 [IQR, 32-50]; P < .001) and the lowest level of artifacts (median score, 0 [IQR, 0-0]; P < .001). The concordance between Bhalla scores for synthetic and real CT images was almost perfect (intraclass correlation coefficient, ≥0.92). Conclusion Synthetic CT images showed almost perfect concordance with real CT images for the depiction of CF-related pulmonary alterations and had better image quality than UTE MRI. Clinical trial registration no. NCT03357562 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Schiebler and Glide-Hurst in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Longuefosse A, Raoult J, Benlala I, et al. Generating High-Resolution Synthetic CT from Lung MRI with Ultrashort Echo Times: Initial Evaluation in Cystic Fibrosis. Radiology. 2023. PMID: 37404152. doi:10.1148/radiol.230052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。