初步临床研究采用超声振动弹性成像(UVE)在100、150、200 Hz下测量特发性颅内高压所致视乳头水肿患者与对照者的视神经和巩膜剪切波速度、弹性与黏性。6例患者与6例对照的右眼巩膜剪切波速度在100 Hz时显著高于对照,视神经无显著差异;弹性在视神经和巩膜均见显著差异。结论提示UVE有望无创评估视乳头水肿。

要点

  • 右眼巩膜剪切波速度100 Hz时患者5.91±0.54 m/s vs 对照3.86±0.56 m/s,p<0.0001。
  • 右眼视神经剪切波速度100 Hz时患者与对照无显著差异(p=0.1100)。
  • 右眼弹性患者视神经14.42±6.59 kPa vs 对照6.5±5.71 kPa,p=0.0065;巩膜33.04±10.62 vs 9.16±7.15 kPa,p<0.0001。

核心结论

  • UVE系统可无创评估眼部不同组织硬度,视乳头水肿患者后巩膜比视神经更硬,UVE可能成为评估视乳头水肿的无创技术。

研究设计与样本

  • 初步临床研究,纳入6例特发性颅内高压所致视乳头水肿患者和6例对照,对每名参与者视神经和后巩膜两个位置进行UVE测量,剪切波速度在100、150、200 Hz三个频率下测量,采用直径1.5 mm×3.0 mm的圆形感兴趣区二维速度图分析,通过三个频率的波速色散分析弹性和黏性。

诊断标准与关键数值

  • 右眼巩膜剪切波速度100 Hz时患者5.91±0.54 m/s vs 对照3.86±0.56 m/s,p<0.0001。
  • 右眼视神经剪切波速度100 Hz时患者3.62±0.39 m/s vs 对照3.36±0.35 m/s,p=0.1100。
  • 右眼弹性:视神经患者14.42±6.59 kPa vs 对照6.5±5.71 kPa,p=0.0065;巩膜患者33.04±10.62 kPa vs 对照9.16±7.15 kPa,p<0.0001。
  • 左眼黏性:视神经患者8.89±4.37 Pa·s vs 对照7.27±5.01 Pa·s,p=0.3790;巩膜患者16.05±10.79 Pa·s vs 对照8.49±6.09 Pa·s,p<0.0194。

临床应用与阅片要点

  • 作者认为UVE可能成为评估视乳头水肿的无创技术,本研究仅为初步可行性验证。
  • 本研究中后巩膜黏弹性高于视神经,视乳头水肿患者后巩膜比视神经更硬。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to evaluate our novel ultrasound vibro-elastography (UVE) technique for assessing patients with papilledema by non-invasively measuring shear wave speed (SWS), elasticity and viscosity properties of the optic nerve and sclera.

METHODS: Shear wave speeds were measured at three frequencies-100, 150 and 200 Hz-on the optic nerve and sclera tissues for assessing patients with papilledema resulting from idiopathic intracranial hypertension (IIH). The method was evaluated in six papilledema patients and six controls on two separate locations for each participant (i.e., optic nerve and posterior sclera). SWSs of the optic nerve and sclera were analyzed by using a 2-D speed map technique within a circular region of interest (ROI) (i.e., the diameter of the ROI was 1.5 mm × 3.0 mm at the optic nerve and sclera, respectively). Elasticity and viscosity were then analyzed using the wave speed dispersion over the three frequencies.

RESULTS: We measured values of SWS at both locations, optic nerve and sclera, of the right eye and left eye at three different frequencies in IIH patients and controls. The SWS (mean ± standard deviation [m/s]) of the right eye was significantly higher at the sclera in IIH patients compared with controls (i.e., patients vs. controls: 5.91 ± 0.54 vs. 3.86 ± 0.56, p < 0.0001 at 100 Hz), but there was no significant difference at the optic nerve (i.e., patients vs. controls: 3.62 ± 0.39 vs. 3.36 ± 0.35, p = 0.1100 at 100Hz). We observed increased elasticity (kPa) in IIH patients, indicating there are significant differences in elasticity between patients and controls at the optic nerve and sclera (i.e., right eye [patients vs. controls]: 14.42 ± 6.59 vs. 6.5 ± 5.71, p = 0.0065 [optic nerve]; 33.04 ± 10.62 vs. 9.16 ± 7.15, p < 0.0001 [sclera]). Viscosity was also (Pa·s) higher in the sclera and optic nerve of the left eye (i.e., left eye [patient vs. control]: 8.89 ± 4.37 vs. 7.27 ± 5.01, p = 0.3790 (optic nerve); 16.05 ± 10.79 vs. 8.49 ± 6.09, p < 0.0194 [sclera]).

CONCLUSION: This research illustrates the feasibility of using our UVE system to evaluate stiffness of different tissues in the eye non-invasively. It suggests that the viscoelasticity of the posterior sclera is higher than that of the optic nerve. We found that the posterior sclera is stiffer than the optic nerve in patients with papilledema resulting from IIH, making UVE a potential non-invasive technique for assessing papilledema.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Bui NT, Kazemi A, Sit AJ, et al. Non-invasive Measurement of the Viscoelasticity of the Optic Nerve and Sclera for Assessing Papilledema: A Pilot Clinical Study. Ultrasound Med Biol. 2023. PMID: 37517885. doi:10.1016/j.ultrasmedbio.2023.07.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。