文献速递神经CT

自动化ASPECTS软件的性能及其作为计算机辅助检测工具的价值

Performance of Automated ASPECTS Software and Value as a Computer-Aided Detection Tool.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-07-27

本研究回顾性纳入175例接受取栓的大血管闭塞急性缺血性卒中患者,比较常规与自动化ASPECTS评分同共识标准的一致性。自动化ASPECTS与共识标准的一致性为中等(加权κ=0.59),与常规评分相似;软件辅助后各评分者与共识标准的一致性及评分者间一致性均改善。

要点

  • 自动化ASPECTS与共识标准一致性中等(加权κ=0.59),与常规评分相似。
  • 软件辅助可提高各评分者与共识标准的一致性及评分者间一致性。
  • 软件辅助可能使临床实践中的ASPECTS评分更统一。

核心结论

  • 自动化ASPECTS与共识标准的一致性同常规ASPECTS相似,但在NCCT评估中纳入自动化ASPECTS可改善与共识标准的一致性及评分者间一致性,可能使临床评分更统一。

研究设计与样本

  • 回顾性收集连续接受取栓的大血管闭塞急性缺血性卒中患者影像数据,共175例,由5名评分者在基线NCCT上行常规ASPECTS评分,同一NCCT经RAPID软件处理获得自动化ASPECTS,以共识标准为参考。

诊断标准与关键数值

  • 常规ASPECTS各评分者与共识标准的一致性加权κ=0.38~0.76(一般至良好),自动化ASPECTS加权κ=0.59(中等);按指南取栓资格二分为ASPECTS 0-5 vs 6-10时,软件辅助后总体Fleiss κ=0.15-0.23(P<.001)改善至0.39~0.55(P=.01)。

临床应用与阅片要点

  • 在急性卒中NCCT评估中纳入自动化ASPECTS输出,可改善与共识标准的一致性及评分者间一致性,可能使临床实践中的评分更统一。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: ASPECTS quantifies early ischemic changes in anterior circulation stroke on NCCT but has interrater variability. We examined the agreement of conventional and automated ASPECTS and studied the value of computer-aided detection.

MATERIALS AND METHODS: We retrospectively collected imaging data from consecutive patients with acute ischemic stroke with large-vessel occlusion undergoing thrombectomy. Five raters scored conventional ASPECTS on baseline NCCTs, which were also processed by RAPID software. Conventional and automated ASPECTS were compared with a consensus criterion standard. We determined the agreement over the full ASPECTS range as well as dichotomized, reflecting thrombectomy eligibility according to the guidelines (ASPECTS 0-5 versus 6-10). Raters subsequently scored ASPECTS on the same NCCTs with assistance of the automated ASPECTS outputs, and agreement was obtained.

RESULTS: For the total of 175 cases, agreement among raters individually and the criterion standard varied from fair to good (weighted κ = between 0.38 and 0.76) and was moderate (weighted κ = 0.59) for the automated ASPECTS. The agreement of all raters individually versus the criterion standard improved with software assistance, as did the interrater agreement (overall Fleiss κ = 0.15-0.23; P < .001 and .39 to .55; P = .01 for the dichotomized ASPECTS).

CONCLUSIONS: Automated ASPECTS had agreement with the criterion standard similar to that of conventional ASPECTS. However, including automated ASPECTS during the evaluation of NCCT in acute stroke improved the agreement with the criterion standard and improved interrater agreement, which could, therefore, result in more uniform scoring in clinical practice.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Lambert J, Demeestere J, Dewachter B, et al. Performance of Automated ASPECTS Software and Value as a Computer-Aided Detection Tool. AJNR Am J Neuroradiol. 2023. PMID: 37500286. doi:10.3174/ajnr.A7956

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。