多模态超声与甲状腺影像报告和数据系统标准在推荐甲状腺结节细针穿刺中的比较
前瞻性研究纳入9家三级医院445例甲状腺结节患者,比较常规超声、应变弹性成像和对比增强超声组成的多模态超声与ACR TI-RADS在推荐细针穿刺中的诊断性能。多模态超声模型AUC最高为0.85,TI-RADS最低为0.63(P < .001);50%风险阈值下多模态超声可避免31%的FNA,TI-RADS为15%(P < .001)。
要点
- 多模态超声模型推荐FNA的AUC为0.85,高于TI-RADS的0.63(P < .001)。
- 50%风险阈值下多模态超声可避免31%的FNA,TI-RADS为15%(P < .001)。
- 多模态模型纳入患者年龄及常规超声、弹性成像和CEUS特征。
核心结论
- 多模态超声在推荐FNA以避免不必要的活检方面性能优于TI-RADS。
研究设计与样本
- 前瞻性研究,2020年10月至2021年5月连续纳入9家三级转诊医院的445例甲状腺结节患者,最终分析434例参与者(平均年龄45岁±12[SD],307例女性)的434个经病理证实的甲状腺结节(259个恶性)。
诊断标准与关键数值
- 多模态超声模型推荐FNA的AUC为0.85(95%CI:0.81,0.89),TI-RADS的AUC为0.63(95%CI:0.59,0.68),两者比较P < .001。
临床应用与阅片要点
- 多模态超声模型纳入参与者年龄、常规超声特征(囊性成分比例、回声、边缘、形状、点状强回声灶)、弹性成像特征(硬度)和CEUS特征(血容量)。
- 50%风险阈值下,多模态超声可避免31%(95%CI:26,38)的FNA操作,TI-RADS可避免15%(95%CI:12,19),P < .001。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Current guidelines recommend the use of conventional US for risk stratification and management of thyroid nodules. However, fine-needle aspiration (FNA) is often recommended in benign nodules. Purpose To compare the diagnostic performance of multimodality US (including conventional US, strain elastography, and contrast-enhanced US [CEUS]) with the American College of Radiology Thyroid Imaging Reporting and Data System (TI-RADS) in the recommendation of FNA for thyroid nodules to reduce unnecessary biopsies. Materials and Methods In this prospective study, 445 consecutive participants with thyroid nodules from nine tertiary referral hospitals were recruited between October 2020 and May 2021. With univariable and multivariable logistic regression, the prediction models incorporating sonographic features, evaluated with interobserver agreement, were constructed and internally validated with bootstrap resampling technique. In addition, discrimination, calibration, and decision curve analysis were performed. Results A total of 434 thyroid nodules confirmed at pathologic analysis (259 malignant thyroid nodules) in 434 participants (mean age, 45 years ± 12 [SD]; 307 female participants) were included. Four multivariable models incorporated participant age, nodule features at US (proportion of cystic components, echogenicity, margin, shape, punctate echogenic foci), elastography features (stiffness), and CEUS features (blood volume). In recommending FNA in thyroid nodules, the highest area under the receiver operating characteristic curve (AUC) was 0.85 (95% CI: 0.81, 0.89) for the multimodality US model, and the lowest AUC was 0.63 (95% CI: 0.59, 0.68) for TI-RADS (P < .001). At the 50% risk threshold, 31% (95% CI: 26, 38) of FNA procedures could be avoided with multimodality US compared with 15% (95% CI: 12, 19) with TI-RADS (P < .001). Conclusion Multimodality US had better performance in recommending FNA to avoid unnecessary biopsies than the TI-RADS. Clinical trial registration no. NCT04574258 © RSNA, 2023 Supplemental material is available for this article.
引用
- Xiao F, Li JM, Han ZY, et al. Multimodality US versus Thyroid Imaging Reporting and Data System Criteria in Recommending Fine-Needle Aspiration of Thyroid Nodules. Radiology. 2023. PMID: 37367448. doi:10.1148/radiol.221408
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。