文献速递乳腺乳腺X线

乳腺X线摄影人工智能算法与临床风险模型预测5年乳腺癌风险的比较:一项观察性研究

Comparison of Mammography AI Algorithms with a Clinical Risk Model for 5-year Breast Cancer Risk Prediction: An Observational Study.
PubMed 文献 · Radiology · 2023-01-01

该回顾性病例队列研究纳入2016年在Kaiser Permanente北加州接受阴性筛查乳腺X线检查、随访至2021年的女性,比较五种乳腺X线摄影人工智能算法与BCSC风险模型预测0至5年乳腺癌风险的表现。结果显示,AI算法的时依AUC为0.63至0.67,高于BCSC的0.61(95%CI:0.60,0.62);AI联合BCSC模型的时依AUC为0.66至0.68,略高于单用AI。

要点

  • 阴性筛查乳腺X线检查中,AI算法预测0至5年乳腺癌风险的时依AUC为0.63至0.67,高于BCSC的0.61。
  • AI联合BCSC模型的时依AUC为0.66至0.68,较单用AI略有提高。
  • 该研究为回顾性病例队列设计,结果基于阴性筛查人群。

核心结论

  • 在阴性筛查乳腺X线检查中,AI算法预测0至5年乳腺癌风险的表现优于BCSC风险模型;AI联合BCSC模型进一步改善预测。

研究设计与样本

  • 回顾性病例队列研究,纳入2016年阴性筛查乳腺X线检查、随访至2021年的女性,排除既往乳腺癌或高外显率基因突变者;从324 009名合格女性中随机选取子队列(无论癌症状态),并加入所有额外乳腺癌患者;以索引筛查乳腺X线检查为输入,比较五种AI算法连续评分与BCSC临床风险评分。

诊断标准与关键数值

  • BCSC预测0至5年 incident 乳腺癌的时依AUC为0.61(95%CI:0.60,0.62);AI算法时依AUC为0.63至0.67(Bonferroni校正P < .0016);AI联合BCSC模型时依AUC为0.66至0.68(Bonferroni校正P < .0016)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Although several clinical breast cancer risk models are used to guide screening and prevention, they have only moderate discrimination. Purpose To compare selected existing mammography artificial intelligence (AI) algorithms and the Breast Cancer Surveillance Consortium (BCSC) risk model for prediction of 5-year risk. Materials and Methods This retrospective case-cohort study included data in women with a negative screening mammographic examination (no visible evidence of cancer) in 2016, who were followed until 2021 at Kaiser Permanente Northern California. Women with prior breast cancer or a highly penetrant gene mutation were excluded. Of the 324 009 eligible women, a random subcohort was selected, regardless of cancer status, to which all additional patients with breast cancer were added. The index screening mammographic examination was used as input for five AI algorithms to generate continuous scores that were compared with the BCSC clinical risk score. Risk estimates for incident breast cancer 0 to 5 years after the initial mammographic examination were calculated using a time-dependent area under the receiver operating characteristic curve (AUC). Results The subcohort included 13 628 patients, of whom 193 had incident cancer. Incident cancers in eligible patients (additional 4391 of 324 009) were also included. For incident cancers at 0 to 5 years, the time-dependent AUC for BCSC was 0.61 (95% CI: 0.60, 0.62). AI algorithms had higher time-dependent AUCs than did BCSC, ranging from 0.63 to 0.67 (Bonferroni-adjusted P < .0016). Time-dependent AUCs for combined BCSC and AI models were slightly higher than AI alone (AI with BCSC time-dependent AUC range, 0.66-0.68; Bonferroni-adjusted P < .0016). Conclusion When using a negative screening examination, AI algorithms performed better than the BCSC risk model for predicting breast cancer risk at 0 to 5 years. Combined AI and BCSC models further improved prediction. © RSNA, 2023 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Arasu VA, Habel LA, Achacoso NS, et al. Comparison of Mammography AI Algorithms with a Clinical Risk Model for 5-year Breast Cancer Risk Prediction: An Observational Study. Radiology. 2023. PMID: 37278627. doi:10.1148/radiol.222733

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。