文献速递乳腺技术与安全乳腺X线

评估一种人工智能模型用于预测未来乳腺癌风险

Evaluation of an AI Model to Assess Future Breast Cancer Risk.
PubMed 文献 · Radiology · 2023-01-01

本研究利用英国国家医疗服务体系乳腺筛查计划的OPTIMAM乳腺摄影图像数据库(2010年2月至2019年9月),回顾性配对病例对照设计,评估深度学习模型基于阴性筛查后乳腺摄影预测3年乳腺癌风险的表现;模型总体AUC为0.68(95%CI:0.66,0.70),对晚期癌风险预测AUC为0.72(≥II期)对比0.66(<II期),差异有统计学意义(P=0.037)。

要点

  • AI模型基于筛查前乳腺摄影预测3年乳腺癌风险总体AUC为0.68(95%CI:0.66,0.70)。
  • 模型对晚期癌(≥II期)风险预测AUC为0.72,高于早期癌(<II期)的0.66(P=0.037)。
  • 筛查间期癌与筛查检出癌的预测AUC分别为0.69和0.67,差异无统计学意义(P=0.085)。

核心结论

  • AI模型是乳腺摄影筛查阴性后3至6年乳腺癌风险的强预测因子。

研究设计与样本

  • 回顾性观察性配对病例对照研究,使用英国国家医疗服务体系乳腺筛查计划OPTIMAM乳腺摄影图像数据库2010年2月至2019年9月数据。

诊断标准与关键数值

  • AI模型预测3年乳腺癌风险总体AUC为0.68(95%CI:0.66,0.70)。
  • 筛查间期癌AUC为0.69,筛查检出癌AUC为0.67(P=0.085)。
  • 浸润性癌AUC为0.68,导管原位癌(DCIS)AUC为0.66(P=0.057)。
  • 晚期癌(≥II期)AUC为0.72,早期癌(<II期)AUC为0.66(P=0.037)。
  • 诊断时乳腺摄影检测乳腺癌的AUC为0.89(95%CI:0.88,0.91)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Accurate breast cancer risk assessment after a negative screening result could enable better strategies for early detection. Purpose To evaluate a deep learning algorithm for risk assessment based on digital mammograms. Materials and Methods A retrospective observational matched case-control study was designed using the OPTIMAM Mammography Image Database from the National Health Service Breast Screening Programme in the United Kingdom from February 2010 to September 2019. Patients with breast cancer (cases) were diagnosed following a mammographic screening or between two triannual screening rounds. Controls were matched based on mammography device, screening site, and age. The artificial intelligence (AI) model only used mammograms at screening before diagnosis. The primary objective was to assess model performance, with a secondary objective to assess heterogeneity and calibration slope. The area under the receiver operating characteristic curve (AUC) was estimated for 3-year risk. Heterogeneity according to cancer subtype was assessed using a likelihood ratio interaction test. Statistical significance was set at P < .05. Results Analysis included patients with screen-detected (median age, 60 years [IQR, 55-65 years]; 2044 female, including 1528 with invasive cancer and 503 with ductal carcinoma in situ [DCIS]) or interval (median age, 59 years [IQR, 53-65 years]; 696 female, including 636 with invasive cancer and 54 with DCIS) breast cancer and 1:1 matched controls, each with a complete set of mammograms at the screening preceding diagnosis. The AI model had an overall AUC of 0.68 (95% CI: 0.66, 0.70), with no evidence of a significant difference between interval and screen-detected (AUC, 0.69 vs 0.67; P = .085) cancer. The calibration slope was 1.13 (95% CI: 1.01, 1.26). There was similar performance for the detection of invasive cancer versus DCIS (AUC, 0.68 vs 0.66; P = .057). The model had higher performance for advanced cancer risk (AUC, 0.72 ≥stage II vs 0.66 <stage II; P = .037). The AUC for detecting breast cancer in mammograms at diagnosis was 0.89 (95% CI: 0.88, 0.91). Conclusion The AI model was found to be a strong predictor of breast cancer risk for 3-6 years following a negative mammographic screening. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Mann and Sechopoulos in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Damiani C, Kalliatakis G, Sreenivas M, et al. Evaluation of an AI Model to Assess Future Breast Cancer Risk. Radiology. 2023. PMID: 37310244. doi:10.1148/radiol.222679

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。