离散化与插值参数对胰腺癌手术队列CT影像组学特征预测能力的影响有限
研究纳入144例术前行高对比CT的胰腺癌患者,按IBSI指南处理图像,改变15组插值/离散化参数(体素0.21–27 mm³、灰度级32–128),评估80个影像组学特征的变化及其对早期远处复发(EDR,<10个月)的判别能力;结果显示特征变异性大但AUC变化有限,判别能力相对稳定。
要点
- 80个CT影像组学特征中仅30个在插值/离散化参数变化下%COV<20,但特征变异性大并未显著削弱其判别EDR的能力。
- 与EDR显著相关的30个特征AUC约0.60–0.70,AUC标准差均值0.02、极差均值0.05,仅16/30特征AUC极差≤0.05。
- 排除灰度级32和128的极端值后AUC极差进一步缩小(均值0.04,范围0.00–0.08),提示参数选择对预测影响有限。
核心结论
- CT影像组学特征在预测胰腺癌 upfront手术后的早期远处复发时,在较大体素尺寸和灰度级分箱范围内对图像插值/离散化参数相对不敏感。
研究设计与样本
- 单中心回顾性研究?原文未明确说明研究设计类型和中心数;纳入144例术前高对比CT的胰腺癌手术患者,按IBSI指南处理图像,设置15组插值/离散化参数(立方体素0.21–27 mm³、灰度级32–128),排除ICC<0.80及扫描仪间变异不可忽略的特征后分析80个影像组学特征。
诊断标准与关键数值
- 早期远处复发(EDR)定义为术后<10个月复发(按复发时间第一四分位数预先评估);与EDR显著相关的30个特征AUC值约0.60–0.70,AUC标准差均值0.02、极差均值0.05,极差范围0.00–0.11,16/30特征AUC极差≤0.05;排除灰度级32和128后AUC极差均值0.04、范围0.00–0.08。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the variation of the discriminative power of CT (Computed Tomography) radiomic features (RF) against image discretization/interpolation in predicting early distant relapses (EDR) after upfront surgery.
MATERIALS AND METHODS: Data of 144 patients with pre-surgical high contrast CT were processed consistently with IBSI (Image Biomarker Standardization Initiative) guidelines. Image interpolation/discretization parameters were intentionally changed, including cubic voxel size (0.21-27 mm3) and binning (32-128 grey levels) in a 15 parameter's sets. After excluding RF with poor inter-observer delineation agreement (ICC < 0.80) and not negligible inter-scanner variability, the variation of 80 RF against discretization/interpolation was first quantified. Then, their ability in classifying patients with early distant relapses (EDR, < 10 months, previously assessed at the first quartile value of time-to-relapse) was investigated in terms of AUC (Area Under Curve) variation for those RF significantly associated to EDR.
RESULTS: Despite RF variability against discretization/interpolation parameters was large and only 30/80 RF showed %COV < 20 (%COV = 100*STDEV/MEAN), AUC changes were relatively limited: for 30 RF significantly associated with EDR (AUC values around 0.60-0.70), the mean values of SD of AUC variability and AUC range were 0.02 and 0.05 respectively. AUC ranges were between 0.00 and 0.11, with values ≤ 0.05 in 16/30 RF. These variations were further reduced when excluding the extreme values of 32 and 128 for grey levels (Average AUC range 0.04, with values between 0.00 and 0.08).
CONCLUSIONS: The discriminative power of CT RF in the prediction of EDR after upfront surgery for pancreatic cancer is relatively invariant against image interpolation/discretization within a large range of voxel sizes and binning.
引用
- Loi S, Mori M, Palumbo D, et al. Limited impact of discretization/interpolation parameters on the predictive power of CT radiomic features in a surgical cohort of pancreatic cancer patients. Radiol Med. 2023. PMID: 37289267. doi:10.1007/s11547-023-01649-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。