文献速递腹部技术与安全PETCT

术前18F-FDG PET/CT影像组学分析预测胰腺导管腺癌微血管侵犯和神经周围侵犯

Preoperative prediction of microvascular invasion and perineural invasion in pancreatic ductal adenocarcinoma with 18F-FDG PET/CT radiomics analysis.
PubMed 文献 · Clin Radiol · 2023-06-02

该研究回顾性收集170例胰腺导管腺癌患者的术前18F-FDG PET/CT图像及临床病理参数,构建影像组学模型预测微血管侵犯和神经周围侵犯。微血管侵犯预测模型融合PET/CT影像组学特征与两项临床病理参数,AUC为83.08%;神经周围侵犯预测模型仅用PET/CT影像组学特征,AUC为94%。肿瘤体积膨胀3 mm时模型效果最佳。

要点

  • 术前18F-FDG PET/CT影像组学可预测胰腺导管腺癌微血管侵犯,融合临床病理参数后AUC为83.08%。
  • 神经周围侵犯预测仅用PET/CT影像组学特征,AUC达94%,准确率89.33%。
  • 肿瘤周边信息(3 mm膨胀)对微血管侵犯和神经周围侵犯预测均有帮助。

核心结论

  • 术前18F-FDG PET/CT影像组学特征对胰腺导管腺癌微血管侵犯和神经周围侵犯状态具有指导性预测效能,肿瘤周围信息有助于预测。

研究设计与样本

  • 回顾性收集170例胰腺导管腺癌患者的术前18F-FDG PET/CT图像及临床病理参数,对全肿瘤及肿瘤膨胀3、5、10 mm的周围变体提取影像组学特征,采用特征选择算法挖掘单模态和融合特征子集,并用梯度提升决策树进行二分类。

诊断标准与关键数值

  • 微血管侵犯预测模型在18F-FDG PET/CT影像组学特征与两项临床病理参数的融合子集上表现最佳,AUC为83.08%,准确率78.82%,召回率75.08%,精确率75.5%,F1分数74.59%。神经周围侵犯预测模型仅在PET/CT影像组学特征子集上取得最佳预测结果,AUC为94%,准确率89.33%,召回率90%,精确率87.81%,F1分数88.35%。两个模型中肿瘤体积膨胀3 mm均产生最佳结果。

临床应用与阅片要点

  • 作者认为术前18F-FDG PET/CT影像组学预测因子在术前识别胰腺导管腺癌微血管侵犯和神经周围侵犯状态方面具有指导性预测效能,肿瘤周围信息被显示有助于微血管侵犯和神经周围侵犯预测。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To develop and validate a predictive model based on 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG) positron-emission tomography (PET)/computed tomography (CT) radiomics features and clinicopathological parameters to preoperatively identify microvascular invasion (MVI) and perineural invasion (PNI), which are important predictors of poor prognosis in patients with pancreatic ductal adenocarcinoma (PDAC).

MATERIALS AND METHODS: Preoperative 18F-FDG PET/CT images and clinicopathological parameters of 170 patients in PDAC were collected retrospectively. The whole tumour and its peritumoural variants (tumour dilated with 3, 5, and 10 mm pixels) were applied to add tumour periphery information. A feature-selection algorithm was employed to mine mono-modality and fused feature subsets, then conducted binary classification using gradient boosted decision trees.

RESULTS: For MVI prediction, the model performed best on a fused subset of 18F-FDG PET/CT radiomics features and two clinicopathological parameters, with an area under the receiver operating characteristic curve (AUC) of 83.08%, accuracy of 78.82%, recall of 75.08%, precision of 75.5%, and F1-score of 74.59%. For PNI prediction, the model achieved best prediction results only on the subset of PET/CT radiomics features, with AUC of 94%, accuracy of 89.33%, recall of 90%, precision of 87.81%, and F1 score of 88.35%. In both models, 3 mm dilation on the tumour volume produced the best results.

CONCLUSIONS: The radiomics predictors from preoperative 18F-FDG PET/CT imaging exhibited instructive predictive efficacy in the identification of MVI and PNI status preoperatively in PDAC. Peritumoural information was shown to assist in MVI and PNI predictions.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Jiang C, Yuan Y, Gu B, et al. Preoperative prediction of microvascular invasion and perineural invasion in pancreatic ductal adenocarcinoma with 18F-FDG PET/CT radiomics analysis. Clin Radiol. 2023. PMID: 37365115. doi:10.1016/j.crad.2023.05.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。