文献速递心血管MR

三维高分辨率暗血晚钆增强成像改善心房瘢痕评估

Three-dimensional High-Resolution Dark-Blood Late Gadolinium Enhancement Imaging for Improved Atrial Scar Evaluation.
PubMed 文献 · Radiology · 2023-01-01

研究开发自由呼吸导航门控暗血PSIR序列,在20例房颤射频消融术后患者中同步获取高分辨率暗血与亮血三维图像,暗血序列瘢痕-血液对比度0.60 au优于常规亮血序列0.20 au(P < .01),瘢痕面积定量与电解剖标测相关性r=0.66优于常规序列r=0.13。

要点

  • 暗血PSIR序列瘢痕-血液对比度0.60 au,优于常规亮血PSIR序列0.20 au(P < .01)。
  • 暗血序列瘢痕面积与电解剖标测相关r=0.66(P < .01),常规亮血序列r=0.13(P = .63)。
  • 平均扫描时间8.3分钟±2.4,所有受试者均成功完成三维高分辨率采集。

核心结论

  • 在房颤射频消融术后患者中,独立导航门控暗血PSIR序列可产生高空间分辨率暗血与亮血图像,图像对比度和原生瘢痕定量均优于常规亮血图像。

研究设计与样本

  • 前瞻性纳入2019年10月至2021年10月接受射频消融的房颤患者20例(平均年龄62岁±9,16例男性;距射频消融平均89天±26),开发自由呼吸独立导航门控暗血PSIR序列,采集两个配准的高空间分辨率(1.25×1.25×3 mm³)三维容积,以电解剖标测为参考标准。

关键影像表现/征象

  • 暗血成像容积联合反转恢复与T2准备实现暗血,亮血参考容积内置T2准备用于相位敏感重建。
  • 所有受试者均成功获取三维高空间分辨率容积,平均扫描时间8.3分钟±2.4。

诊断标准与关键数值

  • 暗血PSIR序列瘢痕-血液平均对比度0.60 au±0.18,常规亮血PSIR序列0.20 au±0.19,P < .01。
  • 暗血序列瘢痕面积定量与电解剖标测相关r=0.66(P < .01),常规亮血序列r=0.13(P = .63)。

临床应用与阅片要点

  • 暗血PSIR序列可同时提供暗血与亮血图像,用于房颤射频消融术后心房瘢痕的检测与定量。
  • 以电解剖标测为参考标准时,暗血序列瘢痕面积定量相关性优于常规亮血序列。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Radiofrequency ablation (RFA) is a widely used treatment for atrial fibrillation, reducing the risk of cardiac arrhythmia. Detailed visualization and quantification of atrial scarring has the potential to improve preprocedural decision-making and postprocedural prognosis. Conventional bright-blood late gadolinium enhancement (LGE) MRI can help detect atrial scars; however, its suboptimal myocardium to blood contrast inhibits accurate scar estimation. Purpose To develop and test a free-breathing LGE cardiac MRI approach that simultaneously provides high-spatial-resolution dark-blood and bright-blood images for improved atrial scar detection and quantification. Materials and Methods A free-breathing, independent navigator-gated, dark-blood phase-sensitive inversion recovery (PSIR) sequence with whole-heart coverage was developed. Two coregistered high-spatial-resolution (1.25 × 1.25 × 3 mm3) three-dimensional (3D) volumes were acquired in an interleaved manner. The first volume combined inversion recovery and T2 preparation to achieve dark-blood imaging. The second volume functioned as the reference for phase-sensitive reconstruction with built-in T2 preparation for improved bright-blood contrast. The proposed sequence was tested in prospectively enrolled participants who had undergone RFA for atrial fibrillation (mean time since RFA, 89 days ± 26 [SD]) from October 2019 to October 2021. Image contrast was compared with conventional 3D bright-blood PSIR images using the relative signal intensity difference. Furthermore, native scar area quantification obtained from both imaging approaches was compared with measurements obtained with electroanatomic mapping (EAM) as the reference standard. Results A total of 20 participants (mean age, 62 years ± 9; 16 male) who underwent RFA for atrial fibrillation were included. The proposed PSIR sequence successfully acquired 3D high-spatial-resolution volumes in all participants, with a mean scan time of 8.3 minutes ± 2.4. The developed PSIR sequence improved scar to blood contrast compared with conventional PSIR sequence (mean contrast, 0.60 arbitrary units [au] ± 0.18 vs 0.20 au ± 0.19, respectively; P < .01) and correlated with EAM regarding scar area quantification (r = 0.66 [P < .01] vs r = 0.13 [P = .63]). Conclusion In participants who had undergone RFA for atrial fibrillation, an independent navigator-gated dark-blood PSIR sequence produced high-spatial-resolution dark-blood and bright-blood images with improved image contrast and native scar quantification compared with conventional bright-blood images. © RSNA, 2023 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Si D, Wu Y, Xiao J, et al. Three-dimensional High-Resolution Dark-Blood Late Gadolinium Enhancement Imaging for Improved Atrial Scar Evaluation. Radiology. 2023. PMID: 37278633. doi:10.1148/radiol.222032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。