脉络组织-大脑前动脉距离(TACAD):彩色多普勒识别完全性或部分性胼胝体发育不全胎儿的新标志物
本研究在253例19至36周正常健康胎儿中建立TACAD参考范围,并测量28例完全性ACC和18例部分性ACC胎儿。正常胎儿TACAD随孕周增加,22周和30周均值分别为10.1 mm和14.2 mm;完全性ACC胎儿全部(28/28)及部分性ACC胎儿83%(15/18)TACAD显著缩短,均值分别为3.9 mm和6.6 mm。
要点
- 正常胎儿TACAD随孕周增加,22周均值10.1 mm,30周均值14.2 mm。
- 完全性ACC胎儿全部(28/28)TACAD缩短,均值3.9 mm。
- 部分性ACC胎儿83%(15/18)TACAD缩短,均值6.6 mm。
核心结论
- TACAD是胎儿彩色多普勒神经超声中易于获得的测量值,可量化大脑前动脉和胼周动脉的走行;完全性或部分性ACC胎儿的TACAD较正常胎儿缩短,提供客观可量化的数值而非仅描述性信息。
研究设计与样本
- 前瞻性横断面研究,在253例19至36周正常健康胎儿中建立TACAD与孕龄相关的参考范围;研究组包括完全性ACC胎儿28例和部分性ACC胎儿18例。
关键影像表现/征象
- TACAD在脑中矢状切面彩色多普勒上测量,取脉络组织前缘与胼胝体膝部水平大脑前动脉之间的距离。
- 正常胎儿TACAD在妊娠后半期增加,22周均值10.1 mm,30周均值14.2 mm。
- 完全性ACC胎儿全部(28/28)TACAD显著缩短,均值3.9 mm。
- 部分性ACC胎儿83%(15/18)TACAD显著缩短,均值6.6 mm。
诊断标准与关键数值
- 完全性ACC胎儿TACAD均值3.9 mm,正常胎儿22周均值10.1 mm、30周均值14.2 mm。
- 部分性ACC胎儿TACAD均值6.6 mm,83%(15/18)表现为缩短。
临床应用与阅片要点
- TACAD可在胎儿彩色多普勒神经超声的中矢状切面上简单获取,用于量化大脑前动脉和胼周动脉走行。
- 完全性或部分性ACC胎儿TACAD较正常胎儿缩短,可作为客观可量化的辅助指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess objectively the course of the anterior cerebral artery (ACA) by measuring its distance to the tela choroidea in the midsagittal view, and to compare this distance in normal fetuses with that in those with agenesis of the corpus callosum (ACC), a condition known to be associated with an abnormal course of the ACA.
METHODS: The tela-choroidea-to-anterior-cerebral-artery distance (TACAD) was measured in the midsagittal view of the brain on color Doppler, between the anterior border of the tela choroidea and the ACA at the level of the callosal genu. Reference ranges in relation to gestational age were established in a prospective, cross-sectional study of 253 normal healthy fetuses between 19 and 36 weeks of gestation. The study group included fetuses with complete ACC (n = 28) or partial ACC (n = 18).
RESULTS: TACAD of normal fetuses showed an increase during the second half of pregnancy, with a mean value of 10.1 mm and 14.2 mm at 22 and 30 weeks of gestation, respectively. All (28/28) fetuses with complete ACC and 83% (15/18) of those with partial ACC had significantly shorter TACAD, with mean values of 3.9 mm and 6.6 mm, respectively.
CONCLUSIONS: TACAD is a measurement that is simple to obtain during fetal color Doppler neurosonography, which enables quantification of the course of the ACA and pericallosal artery. TACAD is shorter in fetuses with complete or partial ACC than in normal fetuses and provides an objective, quantifiable value, rather than merely descriptive information. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Karl K, Chaoui R. Tela-choroidea-to-anterior-cerebral-artery distance (TACAD): novel marker on color Doppler to identify fetuses with complete or partial agenesis of corpus callosum. Ultrasound Obstet Gynecol. 2023. PMID: 37265109. doi:10.1002/uog.26275
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。